Laserfiche WebLink
INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />MAIN FLOOR PLAN <br />1.1 <br />UPPER FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAIL <br />4 <br />MAIN ELECTRICAL PLAN <br />4.1 <br />UPPER ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />MAIN FRAMING PLAN <br />— <br />7.1 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL DETAILS <br />_ —TT <br />SN <br />STRUCTURAL NOTES <br />SN1 <br />DETAILS <br />S3 <br />DETAILS <br />S4 <br />DETAILS <br />T <br />S5 <br />DETAILS <br />S6 <br />DETAILS <br />ST <br />STAIR DETAILS <br />SS <br />RETROFIT DETAILS <br />ABBREVIATIONS <br />D1 <br />SECTIONS &DETAILS <br />A.B. Anchor Bolt <br />F.P. Fireplace <br />P.T. Pressure Treated <br />Abv. Above <br />F.O.M. Face Of Masonry <br />Pwd. Powder Room <br />D2 <br />SECTIONS & DETAILS <br />C A/Air-Conditioner <br />A/C Adjustable <br />Ft. Foot/ Feet <br />Rad. Radius <br />WP <br />WATERPROOFING DETAILS <br />A.F.F. Above Finished Floor <br />Ftg. Footing <br />FIX Fixed <br />Ref. Refrigerator <br />Req'd. Required <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />A.H.U. Air Handler Unit <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />ALT. Alternate <br />Galy. Galvanized <br />Rm. Room <br />B.A. Base Cabinet <br />BF Bifold Door <br />G.C. General Contractor <br />G.F.I. Ground Fault Interrupter <br />Rnd. Round <br />R/S Rod and Shelf <br />PA1.2 <br />PRODUCT APPROVAL NUMBER <br />Bk h BookShelf <br />Bm. Beam <br />G.T. Girder Truss <br />SD. Smoke Detector <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />Bot. Bottom <br />Hdr. Header <br />Hgt. Height <br />S.F. Square Ft. <br />Sh. Shelves <br />B.P. Bypass door <br />Bearing <br />HB Hose Bibb <br />Int. Interior <br />SHT Sheet <br />S.L. Side Lights <br />Cir. <br />ir. Circle <br />Clg. Ceiling <br />CJ Control Joint <br />Col. Column <br />K/Wall Kneewall <br />K.S. Knee Space <br />Laun. Laundry <br />S.P.F. Spruce Pine Fir <br />Sq. Square <br />S.Y.P. Southern Yellow Pine <br />Comm. Community <br />Comp. Compressor <br />C.T. Ceramic Tile <br />Lay. Lavatory <br />L.F. Linear Ft. <br />ILL Lintel Length <br />TB Towel Bar <br />Temp. Tempered <br />Thik'n. Thicken <br />D. Dryer <br />Door lve <br />LT. Laundry Tub <br />Mas. Masonry <br />T.O.B. Top of Block <br />T.O.M. Top of Masonry <br />3 <br />Dec. Deco atiDB <br />T.O.P. Top of Plate <br />Ded. Dedicated Outlet <br />Dbl. Double <br />Max Maximum <br />M.C. Medicine Cabinet <br />TR TOWEL RING <br />Dia. Diameter <br />Mfgr. Manufacturer <br />TP TOILET PAPER <br />Disp, Disposal <br />Micro. Microwave <br />Trans. Transom Window <br />Dist. Distance <br />Min Minimum <br />Typ. Typical <br />cc"I <br />D.S. Drawer Stack <br />M.L. Microlam <br />U.C. Under Counter <br />[.l <br />D.V. Der Vent <br />ry <br />Mir. Mirror <br />UCL Under Cabinet Lighting <br />� <br />D.W. Dishwasher <br />Mono Monolithic <br />U.N.O. Unless Noted Otherwise <br />9 <br />'t' <br />Ea. Each <br />E.W. Each WayN.T.S. <br />Not to Scale <br />V. Shower Valves <br />VB Vanity Base <br />Zo <br />Elec, Electrical <br />Opn'g. Opening <br />Vert. Vertical <br />N <br />Elev. Elevation <br />Opt. Optional <br />V.L. Versalam <br />°2 <br />Ext. Exterior <br />Pc: Piece <br />VTR Vent through Roof <br />Hi <br />Exp. Expansion <br />Ped. Pedestal <br />w Washer <br />m <br />FBC Florida Building Code <br />PH PHONE <br />W/ With <br />r <br />Fin. Flr. Finished Floor <br />P.L. Parallam <br />W/C Water Closet <br />' <br />4 <br />F.G. fixed Glass <br />PLF Pounds per linear foot <br />W.A. Wedge Anchor <br />Flr. Floor <br />Pit. HI. Plate Height <br />Wd Wood <br />Fdn. Foundation <br />Pit Sh. Plant Shelf <br />WP Water Proof <br />4, <br />Flr Sys Floor System <br />PSF Pounds per square foot <br />x <br />N <br />o <br />REVISIONS <br />J <br />N <br />08-20-15 1.0 NEW BASE PLAN <br />r <br />12-08-15 2.0 FRAME-WAL REVISIONS <br />12-22-16 3.0 Al B1 ELEV. REVISIONS <br />01 —04-1 8 4.0 2017 FBC UPDATES <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />02 -21-18 5.0 ADDED GRADE BEAM 150 MPH ENG. <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />E <br />FOR 2 STORY HOMES <br />E <br />03-29-18 5.1 UPDATED PER CITY COMMENTS <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />y <br />14 <br />CURRENT CODE IS VALID <br />`` <br />AFX FA <br />17= <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />cal <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />8 <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />a <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />co <br />ALL WORK sH � _ C <br />C <br />construction. All construction MUST be in accordance to the <br />o <br />C"INAiION�L <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />RiDA BUILC1ING ®�� REVAILING PLANS Yj�J+iILL <br />®� <br />AND THE !✓;LE 'C`�f% t 1E" "��(�i <br />Office at (407) 880-2333 immediately. No backcharges will be <br />2575 <br />considered for reimbursement by the Designer/Engineer without <br />DES <br />advanced notification and approval by the Designer/Engineer. <br />N <br />Payments will be made in accordance to the terms of the <br />agreement. <br />(D <br />Z M <br />0 <br />Z <br />U) z <br />V) cD <br />cn <br />+- Lu <br />� o <br />O LU <br />TO <br />E <br />U <br />w <br />F- 8 <br />N M <br />r M Cn <br />O o w <br />S <br />1I1 <br />t LL 00 <br />oYi7_1 <br />o <br />¢ rn <br />v a <br />M Q o <br />HDC 4 <br />N CAll <br />`�~ � °rC�s r�• s" <br />CID <br />frr� <br />0 <br />III`IIIII'IIM • M N <br />� <br />DD <br />� "z <br />U �i <br />.J <br />�.A � <br />s .N <br />ta+ <br />� M1J7• <br />N <br />r//'rI°f+'lt <br />�4i 6 rat"' <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />O <br />Z N <br />� <br />0 <br />.N <br />15 <br />�>-it)MO <br />M <br />Q�p� <br />a- V) <br />Lr) <br />F- � M <br />ro <br />U CD- 00 <br />Q <br />Z <br />WJ <br />00 <br />d' <br />MJ <br />oZ <br />04 <br />Zg <br />�a <br />WZ-a <br />U48,0 <br />Z LUWM <br />Q,nwZ <br />J <br />J <br />Lu O <br />OwuF.N <br />V..I <br />O W <br />LU <br />Z Z <br />QO <br />CY— <br />s <br />w <br />O <br />Ln <br />0 <br />U <br />Z <br />U <br />= <br />N <br />� <br />o� <br />0 <br />T8_ <br />o <br />Xn <br />U Y m a <br />k <br />N <br />Zro-Lu w�� <br />z <br />c <br />Waco <br />z <br />LU <br />� <br />LL' <br />� F Z <br />UJ <br />Q <br />E <br />z <br />g¢� <br />Z <br />0000 <br />Z <br />F�Z <br />m <br />o <br />�Z <br />rn <br />_ <br />r__1 <br />a <br />Ln <br />SCALE : AS NOTED <br />DATE : 3/29/2018 <br />TECH: JMUROSKI <br />VERSION NO. 5ol <br />SHEET NO. <br />C S <br />L ,.,�, <br />