My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3035 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3035 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 5:43:27 PM
Creation date
2/27/2025 11:15:54 AM
Metadata
Fields
Template:
Building Plans
Street #
3035
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
20297
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYP Cal 2 STORY <br />J <br />S6 <br />H.B.t <br />43'-0" <br />(3) 2X4 #2 SPF W/ (3)16d <br />1 <br />TOENAILS @ BASE 8 <br />COND. COND, <br />J <br />S6 <br />TYP @ 2 STORY <br />7 <br />I I I I I IG I <br />1 1 1 1 I S3 Mao <br />I I I IUP 16R1 I I ih <br />I I 1 1 1 1 I I$ <br />o <br />3 4 5 <br />00 <br />FLOOR G.T. <br />9 <br />Io <br />FAMILY ROOM <br />8'-8" FLAT CLG. <br />CARPET `O <br />� <br />-- -- <br />42"SLOPING o 10 <br />HALF WALL 11 - -- <br />(W� �3) #6 SPF 12 - - - <br />TOENAILS @ <br />BASE <br />G 8'-8' T o <br />00 j -v <br />00 <br />FLEX <br />8'-8" FLAT CLG. <br />CARPET <br />Cl) <br />6) <br />N <br />OS3 <br />Cl) <br />4'-0" <br />(2) #5'S co <br />Q <br />X = <br />5-SH °P <br />H4 <br />o <br />r <br />2" DEEP T <br />__-_-__-__- <br />in <br />2068 B.F. <br />HDR AT T-4" —}— <br />E NTR <br />N <br />16-48" <br />I <br />T-8" 3' 8" 3'-6" <br />6 0" - <br />" FLAT CL�. <br />J <br />S6 <br />C7 C71 C7 r <br />FOYER <br />I <br />- j <br />_ <br />! <br />_ <br />TYP @ 2 STORY <br />(3) 2X4 #2 SPF W/ <br />(3)16d TOENAILS @ <br />BASE <br />r <br />o <br />co U) <br />LO DINING ROOM <br />PATIO O� 8'-8" FLAT CLG. <br />CARPET <br />°C LO <br />Qp1 p 01 <br />J J J <br />"- u- U_ <br />8'-8" FLAT CLG. <br />TILE <br />3068 I I <br />(2) #5'S <br />- <br />0 <br />W.H. <br />(3 2X4 #2 SPF W/ <br />) <br />"' (3)16d TOENAILS <br />O @BASE <br />2'-6" BUILDER TO PROVIDE <br />APPLIANCE PROTECTION <br />WHEN REQUIRED PER FBC <br />2 CAR GARAGE <br />CC <br />F-------- --- <br />D <br />S3 <br />I <br />I <br />I <br />4._0" <br />011 <br />N <br />I I <br />I I <br />I I <br />I I <br />8'-8" FLAT CLG. <br />I <br />I I <br />4'-0" 6-2" k 6-6" <br />4'4" <br />20'-8" <br />I <br />I <br />I I <br />I I <br />EDGE OF SLAB 2" <br />BEYOND WALL Mb� <br />CC <br />IO <br />I <br />I C, <br />I H L u <br />I O 7 <br />w <br />I p <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I I <br />o <br />iD <br />o <br />N <br />_ <br />>- <br />F-1 F l <br />--------- - <br />3 36 36 3 <br />: <br />:Z <br />i <br />- <br />- <br />O� <br />N <br />I <br />I <br />I <br />I <br />I I <br />I <br />I I <br />I I <br />3 <br />-I <br />�' <br />-8' <br />FL <br />T C <br />G. <br />1 <br />. <br />60 <br />I <br />I <br />I <br />I I <br />1. <br />2 68 <br />668 <br />B. F. <br />1 — <br />424 24 <br />I - <br />L - - - - - -�- <br />2x6 WALL <br />D <br />S3 <br />I <br />L - - - - - - - - - - - - <br />I I <br />I <br />REF. <br />OPT. <br />_ _ <br />PANTRY - <br />- <br />iv <br />16" DEEP _ <br />5-SH _ <br />ill <br />(V <br />J H.B. <br />S6 TYP @ 2 STORY <br />w <br />a� <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 4 <br />S.H. <br />13 <br />20 X 38 J <br />181 X 371 <br />S.H. <br />14 <br />20X501 <br />184X50 <br />S.H. <br />15 <br />20X63 <br />18JX624 <br />S.H. <br />16 <br />20X72 <br />18jX714 <br />S.H. <br />432 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />33 <br />27 1/4 X 38 <br />34 <br />27 4 X 50 <br />NIA <br />S.H. <br />433 <br />N/A <br />26 x 37 <br />S.H. <br />} 34 <br />N/A <br />26 x 50 <br />S.H. <br />435 <br />27 4 X 63 <br />26 X 62 112 <br />S.H. <br />7' 36 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 i <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 j X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />734 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 4 <br />S.H. <br />33 <br />54 X 38 j <br />521 X 371 <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 X 62 <br />S, H. <br />36 <br />54 X 72 <br />52 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is Iocated.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />0 <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />Q)[ <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET �H SEE SIN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />LLLL1 I I IIjjjjj BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 11131" <br />1ST FLOOR LIVING AREA <br />1093 <br />2ND FLOOR LIVING AREA <br />1489 <br />LIVING TOTAL <br />2582 <br />GARAGE <br />FRONT ENTRY <br />TOTALAREA <br />INSULATION REQ. <br />427 <br />35 <br />3044 <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />a <br />UI V <br />co <br />� <br />z <br />Q <br />a <br />C� o <br />O lam' <br />E <br />or- <br />�V) r-- <br />m r- <br />U <br />W <br />E � <br />N M <br />N ;O M <br />Ooo <br />—r3 <br />U <br />L LL M <br />cn '� o <br />�o <br />Q m <br />LO0 <br />rn Q o <br />Al <br />I <br />N wC� <br />.00 <br />13 <br />O �//\�t� � J �M <br />OU ) <br />l.L <br />_ <br />JLUd <br />m <br />` uu <br />JOE <br />aeo 9k, <br />Ir L <br />LL <br />m <br />M• • ° <br />Q� `tin <br />S Oy <br />ems` <br />r t <br />it <br />To the best of the Engineer's n w, dg , Ih ormation, and <br />belief, the structural plans an pecific tions contained <br />within these drawings comply 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />O <br />Z <br />O N n <br />�(j MOO <br />M <br />Q U <br />Ln <br />Q LL <br />F-�" M <br />cj� V a 00 <br />Q <br />z <br />W <br />Cr' <br />oZ <br />ZO <br />w� <br />z¢a <br />�F <br />w��� <br />UZoo <br />Z Lu W <br />z <br />�2zuz <br />Ya2in <br />O 1:4 u- O <br />UO�O <br />z <br />> <br />O <br />Qu <br />zz <br />O <br />gZ <br />z <br />N <br />LL <br />o <br />0 <br />,� <br />�1 /`� <br />Y 1 <br />U <br />U <br />_ <br />(V <br />T <br />w <br />c2 f <br />O� <br />z <br />0 <br />aYP <br />f�iy? <br />Uam <br />O¢O< <br />W Z� <br />Z <br />z <br />,�-I <br />w°moo <br />w <br />LU <br />J <br />Lfi <br />rl <br />LLI <br />2:Z <br />Lu <br />8 o <br />< <br />Q z o <br />U <br />�a� <br />C:) <br />¢Luz <br />� <br />Z <br />�' v <br />m <br />CV <br />Z <br />W <br />V) o <br />Q <br />Ouj <br />= <br />z <br />,--I <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION N0. <br />5ol <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.