My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3044 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3044 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:55:37 AM
Creation date
2/27/2025 11:16:09 AM
Metadata
Fields
Template:
Building Plans
Street #
3044
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
20163
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S <br />L <br />a <br />co <br />KITCHEN <br />L SEE PLAN FOR LANDING DEPTH � <br />MIN. (3) 2x STUDS REQ'D <br />@ END OF LANDING <br />BELOW HDR. BEAM. <br />STANDARD (3) 2x12 <br />STRINGERS w/ SIMPSON <br />A35/USP MP34 CLIP TO FLOOR <br />SYSTEM OR LANDING FRAMING <br />(2) 2x HDR. REQ'D @ END OF <br />LANDING FOR STRINGERS <br />TO CONNECT TO <br />a <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MANSONRY <br />WALL) CONT LEDGER w/ (3) 16d <br />NAILS @ 16" O.C. MAX. TO EA. <br />STUD. ((2) 1/4"X3 1/2" TITENS @ <br />16" O.C. MAX. FOR MASONRY <br />WALL) <br />GENERAL LANDING FRAMING INFO._ <br />SCALE: N.T.S. <br />9'-O" MAX LANDING LENGTH <br />00 <br />00 <br />8'-54" 'A'-n" <br />BATH 2 <br />PLYWOOD @ <br />2x8 LEDGER #2 SYP w/ <br />(3) 16d NAILS TO STUD <br />@ 16" O.C. <br />io <br />KITCHEN <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16" O.C. w/ SIMPSON A35 <br />CLIP OR LUS26 HANGER TO <br />LEDGER I U <br />2x12 HDR. w/ (3) 2x STUDS AT Q <br />EA. END FOR BEARING <br />STANDARD (3) 2X12 I U <br />STRINGERS W/ SIMPSON A35 <br />CLIP TO HDR. <br />I <br />1x TREADS (TYP.) .- <br />CONT. <br />HANDRAIL <br />THRUST BLOCK SECURED TO <br />SLAB w/ 1/4"X31/2" TAPCONS <br />@ 16" O.C. <br />MIRROR <br />O <br />o <br />OWNER'S BATH <br />Q <br />CM <br />4 <br />N <br />O <br />M <br />KITCHEN ISLAND <br />13 <br />--Al I 1W <br />42 J <br />ECr <br />" <br />z. <br />i <br />Ln dUJI <br />i <br />0 06 <br />5ml <br />INTERIOR ELEVATIONS. <br />SCALE: 1 /2"=1'-0" <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 314" <br />PRE-ENG FLOOR JOIST W/ (2) <br />10" TRSEADS w/ 1" NOSING <br />LAYERS OF 3/4" PLYWOOD <br />Stairway construction and handrail to conform to the FBC Residential 6th <br />FOR SOLID NAILING <br />Edition (2017) section R311.7 <br />Riser height: <br />CONT. HANDRAIL <br />The maximum riser height shall be 7Y4". The greatest riser height within any <br />' <br />flight of stairs shall not exceed the smallest by more than <br />1x RISERS (TYP.) <br />Tread depth. <br />The minimum tread depth shall be 10". The greatest tread depth within any <br />STANDARD (3) 2X12 <br />flight of stairs shall not exceed the smallest by more than <br />STRINGERS W/ SIMPSON <br />A35 CLIP TO FLOOR <br />Nosings. <br />SYSTEM <br />The radius of the nosing shall be no greater that V1s". Solid riser nosings shall <br />not be less than Y44" but not more than 1Y4". The greatest nosing projection shall <br />2x8 #2 YP JOISTS @ LANDING <br />not exceed the smallest by more than YZ'• Beveling of nosings shall not exceed <br />@ 16" O. . w/ SIMPSON A35 CLIP <br />Y2, <br />OR LUS2 HANGER EA. SIDE SEE <br />PLAN FOR CLG. HT. <br />Handrails. <br />Handrails shall be provided on at least one side of each continuous run of <br />treads or flight with four or more risers. Handrail height, measured vertically <br />from the sloped plane adjoining the tread nosing, or finish surface of ramp <br />slope, shall be not less than 34" and not more than 38". Handrails adjacent to a <br />wall shall have a space of not less than %"between the wall and the handrails. <br />2x12 HDR. w/ (3) 2x STUDS AT Handrails with a circular cross section shall have an outside diameter of at <br />r!4: 00 EA. END FOR BEARING least 1 1/4" and not greater than 2" or provide equivalent graspavility in <br />compliance with Section R311.7.8.3. <br />ED <br />— — — — Guards. <br />Guards shall be located along open -sided walking surfaces, including stairs, <br />ramps and landings, that are located more than 30" and shall be not less than <br />36". Required guards shall not have openings from the walking surface to the <br />— = required guard height which allow passage of a sphere 4" in diameter. <br />Winders. <br />Winder treads shall have a minimum tread depth of 6" at the narrow end and <br />shall have a minimum tread depth of 10" at the intersections with the walkline <br />(12" from the narrower side). <br />R302.7 Under -Stair Protection. <br />Enclosed accessible space under a stairway shall be protected with''Y2" gyp. bd <br />STAIR SECTION_ <br />SCALE: 1 /2"=1'-0" <br />zo <br />;U <br />
The URL can be used to link to this page
Your browser does not support the video tag.