My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3059 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3059 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 6:59:03 PM
Creation date
2/27/2025 11:16:27 AM
Metadata
Fields
Template:
Building Plans
Street #
3059
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19702
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 11 11 1 I 11 11 1'I 1-1 1 111 1' 1 01 1 1 __1� 1 I I I 1 1 I_ Iff <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />upper to lights & outlets <br />upper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />I <br />I <br />I <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FPF <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />S <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />� <br />220 VOLT OUTLET <br />N <br />CN <br />�' WALL SWITCH <br />�'3 THREE-WAY SWITCH <br />24 FOUR-WAY SWITCH <br />R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />LO <br />g <br />WALL MOUNTED LIGHT FIXTURE <br />J <br />O RECESSED LIGHT FIXTURE <br />� <br />0 <br />LIGHT FIXTURE WITH PULL CHAIN <br />0*114 <br />C. <br />TRACK LIGHT <br />}� FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />3 <br />;Qt EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />i <br />CH CHIMES (OPTIONAL) <br />PIT <br />O PUSHBUTTON SWITCH (OPTIONAL) <br />oSD <br />SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />o` <br />TELEPHONE (OPTIONAL) <br />CnN <br />L` <br />© TELEVISION (OPTIONAL) <br />0 <br />o <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />a <br />c01 <br />O THERMOSTAT <br />i <br />J ELECTRIC METER <br />'o <br />i <br />ELECTRIC PANEL <br />a <br />_ I DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />o <br />cV <br />^ ^ <br />l <br />to( <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />AC PAD <br />DISC. <br />WP <br />GFI <br />WP <br />PATIO <br />I <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />' LIGHT PRE -WIRE <br />OW Nt R' <br />SUITE <br />I <br />BEDROOM 2 <br />ROUGH-IJOR '\\ 12 <br />OPT. CLG. AN/ <br />LIGHT PRE- IRE <br />DEDICATED RECEPTACLE <br />O FOR MICROWAVE RANGE G <br />HOOD PER SPECS—_ -- <br />UU <br />G-ElTr — GFI—_^ <br />RAG - - -- - - - - t� <br />- -� KITHE — -- --!� <br />U.C. SWITCH--- - - - <br />Gftl — 11 <br />FOR DISPOSAL -- <br />DW I •SINKw/- <br />S.D I DIL W <br />O- L_ L=� —O---TDISP f <br />IGFI---- --J GFIi <br />� O <br />I / � <br />/ I <br />ROUGH -IN F�R / <br />/ OPT. CLG. F N/ LIGHT / <br />PRE -WIRE <br />FAMILY ROOM <br />/ <br />T-0" <br />------------ <br />PENDANT AS <br />PER SPECS <br />I CAFE <br />/ <br />3 <br />i <br />VERIFY METER LOCATION <br />WITH BUILDER <br />BEDROOM /ROUGH -IN FOR <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ OPT. CLG. FAN/ <br />LIGHT PRE-WIR&\ l% \ I LIGHE-WARE <br />D *OM 4 <br />)D,H <br />S.D--------� ------ <br />lI - FI @ 44" <br />\li ._ 1 -i O z A.F.F. I------------� <br />H.B. <br /><a <br />U I <br />I <br />� � I <br />WV I <br />w <br />W 2-CAR GARAGE <br />=1@44" ��----�` <br />A.F.F. <br />/ GARAGE 1 I <br />LIGHT AS I GARAGE <br />/ PER SPECS DOOR <br />GFI <br />I <br />I <br />Ilt3-� 11 I <br />u u I <br />L------------ <br />GFI @ 44" A.F.F. <br />A IRRIGATION <br />*WP <br />GFI t <br />ENTRY <br />I <br />I <br />MAIN ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Z M <br />Z <br />z <br />Q <br />a <br />U) z <br />cLn CD <br />W <br />cn <br />i--J LLt <br />�U — <br />O W <br />C <br />E <br />`a o <br />U <br />M th <br />W <br />�e.5 ~ <br />C t0 Cl) <br />O oN <br />LL 00 <br />U <br />5 <br />Sao <br />6 <br />Q C <br />A 1 <br />B De <br />N -C� <br />�. <br />N <br />''ww rn rn <br />�j N <br />o m <br />po <br />M <br />r y M C M <br />LL. N Q � <br />LL J <br />W I.L <br />SE 9 <br />O -,�� <br />C1 <br />d <br />z <br />c:W <br />ZNM <br />-' <br />LL <br />mm <br />UA <br />W N<" D <br />p v <br />C> <br />r <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z� <br />0 � N <br />O <br />Za <br />�>� (1) <br />M <br />Q 'f0 Ln <br />cn •,_ � <br />�LL� <br />a .•. <br />U a OC) <br />Q <br />E <br />3: <br />Z M <br />LU <br />J C:) <br />ko <br />Z <br />w� <br />Z <br />w ¢ Ix <br />o <br />gWZ�Z <br />�W <br />z <br />O&H <br />"gWa <br />Q <br />o <br />fz <br />U <br />= <br />U <br />�W <br />W <br />w <br />> <br />0 <br />a <br />0 <br />J �.y <br />.P <br />uj <br />N <br />ce <br />Q <br />c'e, <br />Y <br />Zo <br />rl <br />o <br />a�o� <br />J <br />ri <br />W <br />W <br />� <br />��� <br />zS <br />N <br />Q <br />Z <br />ag <br />k <br />O <br />N <br />Z <br />Z <br />& Z <br />00 <br />O <br />00 <br />� <br />= <br />Q <br />rn <br />,__q <br />a <br />(n <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAM ES <br />VERSION NO. 4nO <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.