Laserfiche WebLink
MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />^' ^ "^ WEATHER <br />✓E BARRIER & <br />IARILY SECURE <br />WEATHER <br />RESISITIVE <br />BARRIER <br />TAPE - c <br />(A88EMBLEO WINDOW I <br />EXTERIOR <br />SHEATHING <br />WEATHER <br />RESISITIVE <br />BARRIER <br />ED FLASHING <br />HEAD FLASHING TIE-IN INSTRUXTIONS. <br />1. Cut, fold up & temporarily secure weal <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NITS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />r v1Jrt nv� r von nvu <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING3/4"-1" <br />BEAD OF CONSTR. <br />BY LAPPING DOWN <br />ADHESIVE TO BE APPLIED UNDER <br />OVER RIM JOIST AND UP <br />THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />O , <br />OR EQUAL WEATHER PROOF CAULKING <br />O <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS. <br />I UNDER DECKING 1 <br />(SEE DETAIL NG s' � SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"A" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER - <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />iHERED FLASHING <br />8 2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />Q <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF <br />NEEDED IN CORNERS <br />THROUGH SELF -ADHERED <br />FLASHING <br />RUBBERIZED RUBBERIZED ASPHALT <br />ASPHALT ADHESIVE ADHESIVE <br />SELF -ADHERED FLASHING ---, I - <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />L <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground 7 <br />SELF -ADHERED FLASHING ■ SELF -ADHERED FLASHING ■ • FOUNDATION WEEP SCREED <br />DECK JOIST ' OUTSIDE CORNER , • <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance With ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number, marked as #Oin each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />With ASTMC926 <br />over wood 2nd <br />floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />WEEP SCREED DETAIL <br />NOT USED ■ • NOT USED ■ NOT USED V J SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance With <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />u, <br />QD <br />Z c <br />z <br />Z <br />a_ <br />a <br />Z <br />U) <br />CS <br />4-1 w <br />(a C1 <br />-U - <br />O O <br />ITO <br />e <br />o 0 <br />LU <br />W F- <br />LO's <br />co <br />O o N <br />= <br />t� g <br />Q 0, <br />01< d <br />All <br />B D.� <br />=W <br />ao <br />219 <br />fV <br />NN � <br />AM Z Pat: <br />R N <br />� <br />g o <br />J <br />�, N $ O <br />W <br />Wn <br />. <br />W �LL <br />nCK�Z m <br />:1.1 <br />mlli.L <br />mo�6 <br />YjM - <br />W �'< <br />N <br />¢ 0k <br />-'o <br />O <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0! <br />0 <br />0 <br />Z fV <br />O aU N <br />tom- Ln <br />Z <br />M In <br />Q -0 <br />a In •L V <br />(A 0 N <br />N LL <br />CO <br />V aCO <br />Q <br />Z <br />W <br />J � <br />d- <br />z <br />Za <br />8DIX <br />U w <br />Z 2 Z <br />21 W <br />wJE <br />on <br />J <br />8 <br />�- <br />2: <br />W <br />U <br />Z <br />DC <br />�„� <br />0 <br />Z <br />�� <br />D <br />N <br />� <br />L.n <br />O <br />W <br />V <br />= <br />C <br />OC <br />LU <br />a <br />< <br />b <br />F ...:.,, <br />o <br />H <br />a <br />N; <br />j <br />y.I�8S <br />U W R J <br />5&6Q <br />�gce <br />Z <br />^ <br />u_ <br />Q <br />Z <br />iso� <br />$$ <br />N <br />p <br />NM <br />Z <br />Z <br />m <br />O <br />�/ <br />:5= <br />TW <br />W <br />rn <br />,-t <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 1 /31 /2018 <br />TECH: ERAND <br />VERSION NO. 10 <br />SHEET NO. <br />W P <br />