ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />Z5 <br />200 amp <br />150 amp <br />NEMA1 <br />2t10 AMP <br />copper to lights 6 outlets <br />copper to 2g amp ckta <br />.2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />I POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />j TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />------------------------------------------------ <br />GENERAL ELECTRICAL NOTES ■ ■ Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. H.B. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />Installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the AC PAD <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 ROId6Nf11V FAR <br />Wp / <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling I � 61 CLG. FAN/� / <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate VP <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and GFI I ROUGH -IN FOR / LIGHT PRE -WIRE <br />vapor detector sensor, according to the installation. OPT. CLG. FAN/ <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and DISC. �] I LIGHT PRE -WIRE / / ROUGHOPT. CLG. <br />FOR <br />1 ` FAN/ <br />labeled by a Nationally Recognized Testing Laboratory. � /) <br />10. Keep all smoke detectors minimum of 36" from bathroom doors G \ 1 �/ G LIGHT PRE -WIRE <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. G N E R S RECEPT I BEDROOM 3 B E D R O M 2 <br />IL 12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits FOR I <br />is not acceptable. ALARM 1 <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an SYSTEM <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and 1 <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. 1 S.D. S.D. <br />14. Add GFCI protection to receptacles in laundry rooms I' where ' C . I <br />p ect cep es au dry oo sand utility rooms of dwellings he a Installed � � I S.D. AHch <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing _ C.M <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill ( \ <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the-------------J— — — — — — — — — — — — — — -------------- <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. I fC.M <br />WP qP <br />I / <br />ELECTRICAL KEY qP <br />F 00 1 ---- WP <br />I , — _ � -- _' FOYEF� GFI <br />DUPLEX CONVENIENCE OUTLET I I'll <br />M �^�( <br />DEDICATED RECEPTACLE <br />FTFDUPLEX OUTLET ABOVE COUNTER CAE .I/ / FOR MICROWAVE RANGE — <br />w P. WEATHERPROOF DUPLEX OUTLET I HOOD PER SPECS / a33 3 <br />----------- <br />'Zn, I III D.W. I 1 <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET 1 I I f� I GFI @ 44" <br />GFI PATIO I I _ A.F.F. r------------ <br />� II I I <br />DWH.O I I I <br />HALF -SWITCHED DUPLEX OUTLET 1 � I L o f a __1 I I I <br />SPECIAL PURPOSE OUTLET I I I I ENTRY <br />DUPLEX OUTLET IN FLOOR I j O I Yj I I I <br />220 VOLT OUTLET I I I 11 1 I I I <br />$ WALL SWITCH <br />I L _JJ I I I I I I <br />U. . SNIT H <br />$3 THREE-WAY SWITCH I F ( GFI @ / / < L) I I <br />CL <br />�'4 FOUR-WAY SWITCH I _ _ A.F.LLI <br />,F. / J � fI GARAGE I I <br />DOOR <br />$R RHEOSTAT SWITCH -- �' — r ppi LU a 1 GFI I I <br />CEILING MOUNTED LIGHT FIXTURE // ' ROUGH -IN FOR — REF_-- / ' — Q I I I <br />LED LED CEILING MOUNTED LIGHT FIXTURE / LLIIGHT PRE -WIRE /2'CAR GAR U E I I I <br />I I I <br />qP <br />WALL MOUNTED LIGHT FIXTURE //// FAMILY RM / GF <br />W / / I OPT. OPT. I I I <br />ORECESSED LIGHT FIXTURE / / / o — D. I I I <br />LIGHT FIXTURE WITH PULL CHAIN <br />+P.C. <br />TRACK LIGHT /Mill / 1 1 1 <br />/ VERIFY LOCATION IRRIGATION <br />k< FLOURESCENT LIGHT FIXTURE /// ® ELECTRICAL PANEL LtTK <br />FI <br />O <br />EXHAUST FAN <br />;Or <br />EXHAUST FAN/LIGHT COMBINATION <br />VERIFY METER H.B. <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />LOCATION WITH <br />BUILDER <br />CH <br />CHIMES (OPTIONAL) <br />ED <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />W <br />ELECTRIC PANEL <br />—�-1 <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />? <br />c <br />MAIN FLOOR ELECTRICAL PLAN, <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />SCALE: 4'=1'-0" <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />Z <br />z QQ <br />Q <br />J <br />a <br />U) z <br />W <br />0 <br />�V�7)) <br />4- w <br />�V — <br />0 w <br />o <br />LU <br />S <br />M <br />'® <br />o LL. <br />C <br />crt <br />L � <br />Q <br />B D. <br />1�II <br />/r <br />N � N <br />�No �L� <br />HBPIrM_c: <br />toi <br />_C $L <br />r4 <br />r5� m L <br />el- <br />a� NQZ <br />WW�t9 <br />R65 1p,� <br />uZ E <br />mm � $ <br />00 <br />1— <br />U ❑❑ <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />Z N <br />0�� 1 <br />ram♦ V) <br />Z <br />M <br />V) (13 I1 <br />0- <br />N O <br />Z <br />In <br />fQ— CL <br />Q 00 <br />Z E <br />Z M ... <br />W <br />Lu <br />W <br />�a <br />Z <br />o� <br />O W <br />V aUg <br />WL <br />J <br />U <br />Q) <br />Z <br />W <br />X <br />LP) <br />Lu <br />0 <br />� <br />CC <br />0 <br />Lu <br />V <br />S <br />O <br />ILL <br />k <br />^ <br />tt7d3 <br />Z <br />J <br />In <br />I <br />to l <br />Z <br />Z <br />z <br />�$ <br />O <br />m <br />O <br />CV <br />CoUJI <br />Z <br />g <br />= <br />.- 4 <br />a <br />(A <br />SCALE : AS NOTED <br />DATE : 1 /31 /2018 <br />TECH: ERAND <br />VERSION NO' 10 <br />SHEET NO. <br />4.0 <br />