Laserfiche WebLink
1_ I I I I III' P L I I I I1 __!_ �� 4 - I - i I t I Ifl ■ 1 r <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF <br />SPECIFICATIONS_ <br />--------------------- <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />12 <br />5� <br />12 <br />5� <br />- EXTENDED- - - - - <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />-- 6.0 <br />4' RIDGE VENT <br />12 <br />�5 <br />_�-T.O.M. <br />---------- <br />-------_ HDRI <br />0 <br />°D <br />bo <br />zo <br />18' RIDGE VENT <br />F. FL. <br />REAR ELEVATION — 61 <br />SCALE: ,,a"_,.o" <br />R- <br />-- 1 <br />INSTALLED AS PER <br />00011 <br />— - — — -- MANUF SPECIFICATIONS <br />- - - - - - - - - OWN I Am"- - - - - - - - - <br />T.O.M. <br />V-0" 1-4 <br />TEXTURED <br />CEMENTICIOUS <br />F <br />2-4- TEXTURED IN. ON C.M.U. <br />CEMENTICIOUS (NP') o <br />FINISH ON C.M.U. 00 <br />(�'P) 2" x 4" SMOOTH <br />TEXTURED <br />SILL / BAND <br />---------- ------------------------------------------------------------------------ <br />---------------------------- - <br />LEFT ELEVATION <br />— B1 <br />1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />—CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. <br />• O'HAGIN WNEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />'* (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />—Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 66.25 = Amount of O'Hagtn Vents Needed <br />zo <br />z�z <br />Q <br />a <br />z <br />(A U <br />cn <br />•F-r LU <br />p <br />tLJ <br />a: <br />E <br />o <br />i� <br />0 <br />mr- <br />U <br />11J <br />f— <br />$ <br />a� Cn <br />CNM <br />C N <br />O o 00 .0 LL 00 <br />ry; it'd <br />U� <br />00 <br />Y� <br />Q rn <br />ao <br />LO <br />�i < <br />8 Ds <br />"c4e,o.ac <br />f <br />ow <br />Ul <br />w <br />a <br />WLLsa Ld <br />r <br />F S \ <br />.2 \ <br />E $ <br />- <br />To the best of the Engineiir'sW�ip tion, and <br />belief, the structural plans and sp inions contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seat is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />z0 <br />0 <br />o <br />r> ro <br />M <br />Q M Ln <br />CLz Uf •i <br />in ON <br />I_ fl. �M <br />Q � LE� <br />QC U fu <br />Q � <br />Z 170 <br />LU <br />�� <br />J <br />w� <br />zaa <br />fa <br />U <br />z <br />~ <br />w am <br />uzO0 <br />Oo- <br />yzz <br />O J <br />—� <br />gz <br />� <br />W <br />�o <br />ILLJ <br />fz <br />Q) <br />O <br />Z <br />z <br />U <br />= <br />Q <br />3 <br />Q <br />o0 <br />o86 <br />o <br />w fr <br />ouZ19- <br />� 0Cy u.J <br />r�-I <br />Q <br />Lij <br />Q�a <br />Z <br />zo <br />w~~ <br />adz <br />fV <br />N <br />k <br />ON <br />z <br />t-u <br />Z <br />m <br />00 <br />2 <br />�o <br />¢ z <br />SCALE : AS NOTED <br />DATE : 3/19/2018 <br />TECH: MJAMES <br />VERSION NO' 10 <br />SHEET NO. <br />3.2 <br />