Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY; <br />BON <br />TERMINATION <br />NEC 08, 250.94 J <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />opper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />� G F 1 <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />,?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />ll <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />Gr:) <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />RI In nFR <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />0 <br />Z M <br />O <br />o <br />Z <br />Z <br />d <br />O <br />J <br />O <br />Z <br />n�n' <br />CP) <br />�W W <br />V <br />W <br />O CLI <br />m <br />~ <br />0 <br />� <br />~ <br />�� <br />M <br />o0 <br />m � <br />U <br />1u co <br />LU <br />Ep <br />U <br />Elm <br />C(6 M <br />co <br />N <br />O O O <br />ai <br />rE:00 <br />C) <br />cn a 0o rn a �- <br />Qrn <br />rnQo <br />Al <br />'abe <br />N C B• D C <br />f <br />ti <br />o <br />CV <br />N <br />co <br />� CV <br />g � <br />fn 0 rn p <br />000 o <br />O oc) <br />Z o <br />Z W —� <br />� M � C <br />_ ` <br />A/ r ti N - <br />iW co M N <br />W u. <br />a LLJ <br />Wa C tL <br />UQa�r� <br />Z z <br />rn <br />0 <br />00 <br />_ <br />C N O <br />m <br />LL <br />WaNaMr <br />�o <br />Oi— <br />OU <br />U <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O a� <br />�(nM00 <br />M <br />Q '0 <br />(1)LL� <br />E- rS ^ <br />CL' U a OC) <br />Q �✓ <br />E <br />ry <br />Z CD <br />WZ <br />�O <br />[t" <br />J <br />oZ <br />�o <br />zaa <br />fa <br />Z <br />w ¢ iY a <br />J <br />zw�O <br />w� <br />Z <br />0f 0 <br />}a awa <br />Q <br />2)o <br />OU w N <br />U <br />oa <br />oa <br />s_ <br />w <br />oZ <br />Z 0 <br />> <br />`/Lr- <br />` <br />: <br />Lr) <br />Z <br />f l4C <br />Z <br />FY <br />W <br />g <br />N <br />Ln <br />W <br />NO <br />�a ao <br />0 <br />�fU <br />orRZ0�Y <br />Zo <br />4J VW <br />M E-L <br />oQ Zaoa <br />w a J <br />�/ <br />C7aa� <br />Z <br />���o <br />Z <br />LV <br />,�-1 <br />Lli <br />di <br />a <br />a a <br />J <br />rl <br />LL! <br />NQzo <br />Pia <br />Ln <br />M <br />Q <br />Z <br />��o <br />Z <br />anz <br />a <br />�z <br />m <br />� <br />- <br />¢z <br />0 <br />_ <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION N0. 10 <br />SHEET NO. <br />4.0 <br />