My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3241 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3241 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 2:20:51 PM
Creation date
2/27/2025 11:18:10 AM
Metadata
Fields
Template:
Building Plans
Street #
3241
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20194
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />as <br />v <br />v <br />C14 <br />O <br />N <br />n <br />N <br />co <br />i <br />m <br />c <br />LO <br />N <br />0 <br />co <br />co <br />0 <br />bo <br />00 <br />oI <br />N <br />O <br />co ao <br />zo <br />T.O.M. —__--_ <br />DR HGT. <br />F. FL. <br />18' RIDGE VENT <br />12 <br />5� <br />�4' OFFRIDGE <br />3 TAB SHINGLES. ROOF <br />6-0" _ INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />CYTCAIIlC r1 <br />4' RIDGE VENT <br />12 <br />�5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />T.O.M. <br />-- — - — — — — — — — — <br />- <br />-------- <br />TEXTURED <br />CEMENTICIOUS <br />FIN. ON C.M.U. <br />�_ <br />� TEXTURED <br />2%0" <br />(TYP.) <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />2" x 4" SMOOTH <br />(TYP.) <br />TEXTURED <br />SILL / BAND <br />F.FL.- — — — — — — — — — — <br />— <br />--- <br />— — — — — <br />REAR ELEVATION - B1 <br />RIGHT ELEVATION <br />B1 <br />1 /4"=1 V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R906. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ, FT. <br />ova <br />P7 <br />O <br />-- O <br />Z N0 <br />Z <br />E3 <br />z <br />V) (D <br />w <br />+_J <br />C� o <br />•V — <br />O w <br />Lh Of <br />m <br />E <br />U <br />0 (M <br />0 C> <br />m N <br />!8J E <br />— S <br />q) M <br />21 <br />_ <br />m cN <br />O o 0 <br />U <br />e <o <br />5 a:co <br />Cn-6 <br /><C rn <br />.: <br />M Q o <br />B D®� <br />N -c <br />N �O <br />�yo czi, .0 <br />0z <br />ul Z WM� <br />H SIN W <br />Q � L� W <br />_ <br />-.(0m z <br />10 W V ¢-ECL <br />Z <br />0 o 0 <br />W9IUL <br />Wav <br />611,A <br />Co <br />sip•\ 1 r � ��% • •� <br />''�,• •...F Lp •�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />W� <br />is <br />r <br />z <br />O <br />wa�� <br />ZZ <br />' g <br />F— <br />=ozz <br />.0 J <br />' <br />aw�0 <br />LL O <br />LLJLu <br />" o <br />W <br />>g <br />in <br />J J <br />U <br />�/ <br />o z <br />O f <br />J <br />y / <br />W <br />S�Jm�a <br />Lr) <br />CC <br />N <br />rl <br />z Z� <br />Q <br />yJJ�ce <br />at�a <br />Z <br />Z <br />I� <br />*� <br />LLUgLL <br />W-a&� <br />W <br />_1 <br />Lil7 <br />ri <br />diU1FZU <br />LU <br />� ELL <br />O <br />a <br />g~o <br />N <br />Q <br />z <br />z <br />z <br />zo <br />m <br />t <br />z <br />w <br />�Z <br />p <br />ao <br />g <br />= <br />of <br />rn <br />v-i <br />a <br />(n <br />o <br />SCALE : AS NOTED <br />DATE : 4/12/2018 <br />TECH: MJAM ES <br />VERSION NO' 10 <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.