ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />�- <br />FLOURESCENT LIGHT FIXTURE <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />14 copper to lights & outlets <br />12 copper to 20 amp ckts <br />10-2 copper to WH <br />10-3 copper to Dryer <br />or 4/0 SER Alu <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />H,B,' VERIFY METER LOCATION <br />Q EXHAUST FAN WITH BUILDER <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />5D SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />Tat (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />PM ELECTRIC METER <br />51111171_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT, CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />Ch r <br />z co <br />Zo <br />¢C <br />Z <br />n� <br />W c/) <br />L1LJ <br />0 <br />0 LU <br />G` <br />F- <br />O <br />N <br />F <br />o <br />C%i <br />TC ~ <br />0 <br />m r <br />a) co co <br />W <br />ofo <br />U <br />aim <br />C'mM <br />0;d co <br />04 <br />O O O <br />-r aj <br />0) <br />rU_00 <br />':,Ua <br />Y <br />Sao <br />to O `t <br />Q cm <br />I< <br />A , <br />I D� <br />N• C B D C <br />If <br />I <br />/r <br />_ o <br />N <br />N <br />CC) <br />N <br />CCD <br />to 0 a m p <br />00 0 <br />O 00 <br />Z o <br />_ <br />tA Z W "N�z <br />7 0 � <br />J Ci <br />L.L <br />r LL N <br />tv�W a j M .- <br />w <br />a w <br />u- O <br />Z QvLLZ cnO'= <br />O- <br />g <br />3 @wo <br />0 :E gCn0 <br />O o <br />m m <br />�o <br />Wa'TQM <br />N <br />O <br />OU <br />V <br />El <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />C[V <br />Z <br />O a) N <br />P­1 4-Jo <br />I>-aU-)Mc) <br />M <br />Q ' 0 Ln <br />Z <br />V) ON <br />v — Ln <br />Q <br />O.ILL . M <br />� U O. 00 <br />Q <br />Z fa <br />WJ C:) <br />0, <br />3R <br />w� <br />Za <br />F� <br />Z <br />Y WZIQL: <br />ZM-0 <br />WWct <br />jz <br />> 0 W <br />Q <br />aa00. <br />O � LL 0. <br />U <br />N <br />i-No <br />gZ <br />0 <br />aZ <br />Z <br />LJJ <br />J <br />LLI <br />O <br />U <br />= <br />� ¢ <br />Lf <br />O <br />LJ� <br />L <br />LU <br />o <br />Q 0 <br />0 <br />J .w <br />Z <br />N <br />Q <br />Z<a <br />�Qz3 <br />a <br />�' <br />oIIJ 0�0 <br />Z <br />W�gw <br />Z <br />a <br />ao�Z <br />J <br />rl <br />Q <br />57 <br />Q <br />Z <br />tn0Zo <br />LU <br />N <br />M <br />Z <br />tu- <br />¢�Z <br />CY <br />Z <br />W <br />Z <br />�0 <br />a to <br />w <br />•-i <br />a <br />c=n <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />