My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3269 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3269 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 3:43:41 PM
Creation date
2/27/2025 11:18:46 AM
Metadata
Fields
Template:
Building Plans
Street #
3269
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19608
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c <br />a <br />TOM - <br />— <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED - <br />ON DOOR <br />3 TAB SHINGLES. ROOF <br />- — INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />- <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />REAR ELEVATION - B1 <br />SCALE: 1 /4"=1'-0" <br />12 <br />5� <br />14'-0" RIDGE VENT <br />12 <br />5 7-0" RIDGE VENT <br />12 <br />5 <br />1" x 9" SMOOTH <br />TEXTURED <br />FREEZE BAND <br />— --- <br />3 TAB SHINGLES. ROOF <br />MANUF. <br />SPECIFICATIONS <br />— <br />T.O.M. <br />------------------------------------ 1'-00 <br />----------1'-011 HDRHGT. <br />-- - - 1-01 <br />TEXTURED <br />TEXTURED <br />CEMENTICIOUS <br />01 2'-O" FINISH ON C.M.U. <br />(T,P) TEXTURED <br />CEMENTICIOUS 0? <br />FINISH ON C.M.U. <br />(TYP.) <br />---_F.FL. <br />+3" SMOOTH <br />TEXTURED <br />BAND <br />LEFT ELEVATION - 131 <br />" =1'-Orr <br />General Notes <br />ROOF CRITERIA: <br />12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />0- <br />Z M <br />— o <br />z c`flLU <br />z <br />Q <br />J <br />0 <br />(D(^A <br />Q) cn <br />w <br />IM 0 <br />U — <br />w <br />O C <br />I- <br />o <br />i� Vi <br />U <br />W <br />E <br />:_01 �- 8 <br />tM rNi M <br />C CUM <br />l` O M <br />0 0 <br />_ <br />W <br />0 <br />su-co <br />co <br />Cc <br />� <br />C Y <br />QM <br />CL <br />� 0 <br />rnQo <br />A ' <br />B Ds <br />N. C B. 1). C <br />`✓ <br />11�1 <br />0 z <br />C1 �.�.teo <br />V) <br />W <br />M . <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O N <br />t-1 4ma O <br />Ln •� �D O <br />I> -I U M O <br />Q 'gyp In <br />z <br />a v,•Ld- <br />e-, <br />a° � <br />a ^ <br />ce V o. 00 <br />Q <br />z <br />� u <br />z <br />z�(0 <br />J <br />W <br />�z <br />cc <br />z d <br />U <br />f¢ <br />~ <br />O <br />wz- <br />UZ80 <br />Q <br />z <br />szz <br />Q in <br />°-zf- <br />w <br />0�°E,8 <br />" � � <br />L <br />� <br />w <br />is <br />i z <br />w3 <br />a <br />O <br />,d <br />C <br />Z <br />U <br />Q� <br />LU <br />81Z. <br />w . <br />O <br />W <br />wo S <br />N <br />0a <br />Z <br />Q�X� <br />Z <br />W <br />Ln <br />¢w <br />a <br />J <br />r—i <br />L1J <br />Q <br />Lj j <br />Z <br />z u <br />�wZ <br />M <br />m <br />� <br />^� <br />• <br />4Z <br />:5 <br />= <br />W <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.