My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3269 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3269 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 3:43:41 PM
Creation date
2/27/2025 11:18:46 AM
Metadata
Fields
Template:
Building Plans
Street #
3269
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19608
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L_ <br />Y <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA t <br />2Do AMP <br />#14 copper to lights & outlets <br />912 copper to 20 amp clas <br />#10-2 copper to WH <br />#103 copper to Dryer <br />MAIN -W <br />2/0 or 4!0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER_y <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />G E N E RAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />E <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />WP DISC. <br />GFI H.I <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn =o nnr-n1E_ <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) I W.H. VERIFY LOCATION <br />TELEPHONE (OPTIONAL) GFI ----- -----J ELECTRICAL PANEL <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. RECERM <br />FOR ALARM VERIFY METER <br />O THERMOSTAT SYSTEM LOCATBUILDER <br />WITH <br />T <br />ELECTRIC METER <br />NMI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />< J <br />OPT. CEILING FAN <br />89 <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />O <br />Z M <br />— O <br />z <br />Z <br />Q <br />J <br />W <br />LL1 <br />0 <br />U <br />W 0f <br />O~ <br />= <br />O <br />�V) <br />o0 <br />LU <br />co <br />C f6 Cl) <br />LL 0000 <br />� ao <br />U( <br />,e <br />�C.o <br />O <br />Qrn <br />06 <br />rnQo <br />At <br />B Do <br />NCa DC <br />� N <br />N_ <br />t� N <br />co p <br />L` C C) N O <br />O co <br />Z <br />� O <br />i MM�Z <br />A/ Il.. p <br />U_ <br />l.L <br />N <br />CLL 0 <br />w <br />CL <br />W VQrL <br />Z 0 W�gw <br />0 o <br />3M��0 <br />M . <br />gE:rn: <br />QM <br />o <br />W o <br /><0 <br />El El <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z 'V <br />O I� <br />0 <br />� M O <br />M <br />Q M Ln <br />d' <br />IZ cn •L <br />a ��� <br />F- a • f j <br />i� V a 00 <br />a <br />E <br />Z <br />WJ C:) <br />�Z <br />zaa <br />�a <br />Z <br />_3 <br />w 4 Y <br />� <br />ww <br />= z <br />z <br />J <br />Q <br />xf <br />0wo8 <br />U <br />U <br />��W <br />i <br />d" <br />o Z <br />Zo <br />> <br />V, <br />ZZ <br />Wg <br />3 <br />M <br />� <br />W <br />tail <br />�a <br />Lu <br />O <br />0 <br />0 <br />LL <br />Q� <br />J <br />d <br />Z <br />I;0� <br />ZLU <br />N <br />Q <br />� <br />a a <br />$�CK <br />Z <br />Ln <br />a o� <br />J <br />rl <br />6j <br />� <br />t$$a- z 8 <br />" t2 <br />r-I <br />M <br />Q <br />Q <br />Z~Z <br />Lr <br />Z <br />yrj <br />CalZ <br />° <br />g <br />W <br /><Z <br />f <br />,-t <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />