Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />MO <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp clas <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEED—� f <br />INTERSYSTEM �Uf <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />3 <br />WEATHERPROOF DUPLEX OUTLET <br />� <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />CV <br />o <br />I :�;'h SPECIAL PURPOSE OUTLET <br />d.. <br />DUPLEX OUTLET IN FLOOR <br />P 220 VOLT OUTLET <br />co <br />WALL SWITCH <br />x <br />$3 THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />_T4 <br />R RHEOSTAT SWITCH <br />it <br />CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />N <br />M <br />o <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />to <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />e TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />i <br />�+ <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />N <br />o <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />CL <br />o <br />H�g PUSH BUTTON SWITCH - DOOR BELL <br />E <br />SD SMOKE DETECTOR <br />o <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />i <br />TELEPHONE (OPTIONAL) <br />K <br />in <br />TELEVISION (OPTIONAL) <br />a <br />o <br />o <br />Ta 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />i <br />ELECTRIC METER <br />.o <br />i <br />WI ELECTRIC PANEL <br />—�I DISCONNECT SWITCH <br />o <br />® SPEAKER (OPTIONAL) <br />cV <br />O <br />^ <br />to <br />Il\( <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />� <br />G J OPT. CEILING FAN <br />g <br />W (1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H <br />A I I VERIFY LOCATION _IRRIGATION <br />ELECTRICAL PANEL GFI @ 44" A.F.F. I I <br />OPT. I I I <br />FAMILY ki'W" GFI - ° - --W - \ <br />\ \� 2 CAR GARAGE I <br />/2ROUGH-IN FOR I I I <br />OPT. CLG. FAN/ \ — — — — — <br />G LIGHT PRE -WIRE GFI <br />\� OPT. ~ <br />= I II <br />L REF_ J \ o C I GARAGE I I <br />t T-4 " GFI @ \ a I11 DOOR I I <br />I - — - 44" <br />Q to l GFI I I <br />A.F.F. I I <br />I � < / nW. <br />GFI-- -- CAI <br />l U.C. SWITCH — 1 I I I <br />FOR DISPOSAL I T I I I I I I <br />I I I I l�-A, I I I I <br />/� I I I l <br />I II I I <br />Z <br />Z_ a ` ' ' ENTRY <br />_F�IyI I o o L---� I I I <br />�— — � c> I I W.H. O I I I <br />PATIO I III I GI GFI@44" L-----------_ <br />I I i I A.F.F. <br />CAFE I I �— <br />C_ ��` D.W.I j i <br />GFI T <br />DEDICATED RECEPTACLE 1' 3 3--I— 3 <br />FOR MICROWAVE RANGE \ <br />j \ HOOD PER SPECS ` _ _ FOYER <br />0o I M i--�—� I <br />�, _ — - WP <br />WID ; GFI <br />I <br />I <br />GFI I I�. I <br />_ ---- W.I.C.--�-------------- � ----�-------------- <br />C.M + <br />I S.D. I <br />�M I S.D. S.D. <br />OWNER1 RECEPT� BEDROOM 3 <br />/ SU ITFz FOR I ROUGH -IN FOR <br />/ /ALAOPT. CLG. FAN/ <br />SYSTEM! ' _ BEDROOM 2 <br />LIGHT PRE -WIRE <br />/2ROUGH-IN FOR. <br />/ ' `\ OPT. CLG. FAN/ <br />DISC. I� ROUGH -IN FOR f—� -1 LIGHT PRE -WIRE <br />OPT. CLG. FAN/ > <br />WIP I LIGHT PRE -WIRE - _ VP <br />GFIfit <br />OCPAD F! \�•�// VP o► <br />i <br />M <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />M <br />0 <br />o <br />Z <br />r1 <br />U) <br />v7 <br />QXa <br />w <br />'U T <br />�� <br />ra C) <br />Coo r- <br />N <br />IeL3 E <br />t — <br />OI M C" <br />m a <br />2 <br />C-) <br />O_oo <br />C) <br />-r- " o°D0 <br />0 <br /><m <br />o <br />� <br />�aa <br />rn Q o <br />B D® <br />N C VV <br />.N. N <br />U Z Al 'sE,oz z <br />M <br />d <br />LL ^ <br />LY " N a <br />_ >�LLo a <br />t <br />Q LU <br />ZV <br />0 a cn rn <br />O <br />oC'0 <br />MECP <br />LLZ <br />W Q C14¢�E Q <br />O v <br />O <br />U <br />WWW.FDSENG.COM <br />00 <br />0 <br />CV <br />a <br />M <br />ti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampaa.com <br />0 Z <br />tto <br />3Q <br />uj <br />fa <br />z <br />Q <br />�z o <br />U <br />Z w <br />�oZ <br />O Lu <br />dSIJ <br />CL <br />p ro <br />O <br />U <br />LL, <br />m o <br />JJ <br />L <br />ZO <br />sz <br />�- <br />U <br />z <br />L <br />^ <br />J <br />W <br />.0 <br />rr' <br />a <br />`.�Uj <br />O <br />U <br />_ <br />O <br />LJL <br />o00 <br />aYP <br />F _ <br />o <br />J <br />i85 <br />7 <br />`< <br />LLOma <br /><o� <br />ZzWZ� <br />Nw <br />1� <br />as <br />Q <br />o Pj <br />Z <br />Z <br />V -i <br />ii0�o <br />car o <br />J <br />w <br />aW <br />E <br />rl <br />w <br />� <br />0z� <br />U <br />g¢� <br />WIZ <br />z <br />z <br />�<0 <br />U? <br />z <br />n o <br />CD <br />O <br />00 <br />Q <br />J <br />w <br />= <br />�z <br />of <br />rn <br />,--4 <br />a. <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 7/30/2018 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />