Laserfiche WebLink
a� <br />v <br />'x <br />O <br />rn <br />co <br />r <br />I <br />co <br />T3 <br />00 <br />a <br />v <br />0 <br />J <br />rn <br />r` <br />00 <br />c <br />a <br />12 <br />5� <br />12 <br />5� <br />14'-0" RIDGE VENT <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED — <br />ON DOOR <br />12 <br />15 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------------------ <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />15'-0" RIDGE VENT <br />REAR ELEVATION - Al <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF, SPECIFICATIONS <br />HDR HGT. <br />-------- TZ-0" <br />TEXTURED <br />TEXTURED <br />CEMENTICIOUS <br />CEMEFINISH NTICIOUS <br />FINISH ON C.M.U. <br />ON C.M.U. <br />(TYP.) <br />(TYP.) _ <br />OD <br />F.FL. J <br />N <br />O\i <br />N <br />0 <br />W LEFT ELEVATION - Al <br />SCALE: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath, <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />`*CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />0 <br />Cl) <br />O <br />— O <br />z� <br />N <br />Z <br />V) (D <br />� W <br />(Dru <br />p <br />U — <br />O W <br />U <br />m <br />W E <br />C,N <br />C M <br />C M <br />Co <br />M <br />S g? <br />1 <br />O o N <br />i.+- <br />C 0 <br />aaD�o <br />5 <br /><irn <br />U) no <br />u7av <br />A Q d <br />ED. <br />N. C <br />Z_ W z <br />F .g' J C? C <br />cn u- o � W <br />NJ N N A. w <br />L <br />W -'c a <br />Z �(go <br />C <br />Z U) ET-2 <br />UM W <br />� <br />�`o s cbtJt • i <br />0- <br />c <br />�O ,4— <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />4600 W, Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />oZ <br />0 <br />Wo <br />za <br />�f <br />F <br />Z <br />UEOO <br />zoo <br />z <br />_O <br />w z <br />f— <br />=oW <br />J <br />WoC <br />Sm�o <br />W <br />QJ <br />zz <br />Z <br />L <br />(3)o <br />W <br />} V <br />� <br />LU <br />f Z <br />LL <br />� <br />a <br />U) <br />4� <br />-0 <br />O <br />0 <br />Z <br />-W <br />U <br />= <br />¢ <br />LU <br />µo�t,.�oa <br />0 <br />he P <br />Y <br />I. r <br />foLU <br />LU <br />"' <br />fV <br />E <br />z <br />z <br />Z <br />aaU <br />g��g <br />Z <br />T.l <br />Luce <br />W <br />Ln <br />TI <br />lL! <br />c <br />G <br />Lazo <br />V <br />Uf O V <br />O F 8 <br />z <br />00 <br />Q <br />z <br />Z <br />Q <br />�ZS <br />Z <br />$ <br />oJz <br />m <br />rn <br />oo <br />� <br />_ <br />" <br />d <br />U) <br />a <br />SCALE : AS NOTED <br />DATE : 10/29/2018 <br />TECH: MJAMES <br />VERSION NO. <br />4mO <br />SHEET NO. <br />3.2 <br />