My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36083 Carriage Pine Ct
Zephyrhills
>
Building Department
>
Building Plans
>
36083 Carriage Pine Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:03:04 AM
Creation date
2/27/2025 11:21:34 AM
Metadata
Fields
Template:
Building Plans
Street #
36083
Location
Carriage Pine Ct
Contractor
Lennar Homes
Building Plans - Permit #
18396
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1" x 3" SMOOTH <br />TEXTURED <br />BAND 12"R. <br />HEEL _ <br />0 <br />T.O.M. - - <br />HDR HGT. <br />0 <br />00 <br />00 <br />io <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />5� <br />12 <br />5 <br />N <br />12 <br />o-r-------------- <br />- �< <br />F.FL. <br />--------------------------------- <br />1" x 7" SMOOTH <br />TEXTURED <br />SILL / BAND <br />14'-0" RIDGE VENT <br />12 <br />7_�5 <br />„-A” <br />n <br />NOTE: <br />• FIN. TO HAVE TRADITIONAL <br />LOOK & SMOOTH FINISH <br />• FOAM/ EPS MATERIAL IS <br />ACCEPTED <br />NOTCH FOAM <br />DECO BRACKET <br />AS NEEDED <br />DECORATIVE BRACKET <br />H <br />O <br />w <br />3 TAB SHINGLES. ROOF = <br />INSTALLED AS PER MANUF. 3 <br />SPECIFICATIONS p <br />z <br />11-011 <br />F -17 ____ 11 1z <br />E 0 FE7 M M 7E] FF 11 1"x 9" SMOOTH <br />F==� TEXTURED <br />El El EEI El El D HEAD/ BAND <br />[77]� »M ruin------------ <br />12 <br />�5 <br />15'-0" RIDGE VENT <br />NOTE: <br />• W = 1/2 OPENING DIM. <br />• INSTALL OVER STONE, <br />TYP. <br />• FIN. TO HAVE <br />TRADITIONAL LOOK & <br />SMOOTH/ SAND FINISH <br />• FOAM/ EPS MATERIAL <br />IS ACCEPTED <br />uz yr <br />WINDOW winfH <br />2 DECORATIVE SHUTTER <br />FRONT ELEVATION - A <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />------- - - - T.O.M. <br />----------- ---------------------------------- <br />--------------- ------------------------ <br />6" FASCIA <br />(TYP) <br />2'-0" - <br />TEXTURED _ o <br />CEMENTICIOUS o0 60 <br />FINISH ON C.M.U. io <br />(TYP.) <br />F.FL. <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �- <br />LEFT ELEVATION - A <br />It=1'-011 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />'"*G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contractions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion o <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or comics vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ, IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />'If not enough vented soffit is provided due to fire protection, the contractor shall use the <br />following approved vents: <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />-Formula: (Sq. FL Soffit Needed) x 7 = (Sq. In. Needed) / 86,25 = Amount of D'Hagin Vents Needed <br />'a <br />(D <br />Z o <br />— o <br />Z <br />Z <br />Q <br />J <br />d <br />z <br />0Q) <br />4-J LU <br />p <br />�U — <br />p LU <br />� c <br />E <br />o <br />OM <br />a <br />U <br />m <br />M <br />LU <br />� <br />WW~N <br />0 <br />c0 Cl)C <br />O 0 <br />00 <br />2 ai <br />w LL ao <br />Y <br />Q rn <br />f°nnr; <br />0 0 V <br />rnQ o <br />� <br />I <br />....... <br />i• C�1:; E <br />LAN <br />c <br />i It(�• <br />�na�i� <br />co z "� <br />Ale <br />SSI <br />LLW a 0///4tn <br />. <br />J <br />f1101'' 11100 <br />LLI <br />b U <br />U m <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />0 <br />Z N <br />0 cu N <br />CD <br />I>t M 0 <br />M <br />Q "� Ln <br />in •L d" <br />f2 <br />!Z � <br />IY V a p <br />tp <br />Z <br />W J CD <br />zz <br />3� <br />w� <br />za <br />C/) <br />} <br />Z <br />Z8a° <br />Qzz <br />I"_ <br />IZ <br />0 w <br />J <br />J <br />1 • <br />� p <br />LL O <br />LLI <br />J <br />O LOU <br />zo <br />}z <br />W <br />fz <br />O <br />r-1 <br />Lu <br />M <br />Q <br />U) <br />can 3 <br />s <br />0 <br />> <br />o <br />0 <br />U <br />(n <br />ro <br />z <br />< <br />� w <br />O <br />0S <br />0. <br />*k <br />^ <br />ILL <br />W �g <br />Q3. <br />d'_fCoe <br />�ao <br />Z <br />N <br />LU <br />J <br />Ln <br />LI..I <br />W <br />FFj LL <br />{y Y Q <br />�.} <br />Q <br />Z <br />Q <br />LLI Z <br />�1 <br />Z <br />Z <br />m <br />OUJ <br />2 <br />,--i <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />3.1 <br />