ELECTRICAL SPECIFICATION <br />(VOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in comer counters. <br />1W <br />W <br />►1 <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />915 copper to 0pma & ouaets <br />NEidA 1 <br />200 AMP #12 copper to 20 amp dre <br />#10-2 copper tc wH <br />#10.3 copper to Dryer <br />MAIN <br />A41 <br />O0 <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />==j <br />iaconned <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />DISCONNECT H.B. <br />VLVI Vll1 f_V r1LVLr t/lvt-L <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />VERIFY METER <br />LOCATION WITH <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />UlLl� <br />Z O <br />zCD <br />z� <br />Q <br />O <br />J <br />rz <br />Z <br />W <br />rn <br />(D(Zt <br />i--J Lu <br />Q <br />' <br />O w <br />I— <br />V) <br />o <br />H <br />�� <br />M <br />OO <br />m <br />U <br />LU <br />�M <br />C1 t9 M <br />— 0 <br />W®~EM <br />0.20 <br />_ <br />U� <br />LLco <br />00 <br />�o <br />Sao <br />LOa� <br />Qrn <br />rnQo <br />A' <br />NC ByDC <br />C, <br />.n o <br />V N °' . CV <br />Z Z <br />�Z Lou.'> —J-j <br />N <br />N-° �aLLI <br />tL ILL. <br />o'ca <br />W _ N <br />i1 <br />au_LL o <br />ZUDLL 0 <br />in <br />Z <br />oQ <br />_O:�aoa <br />ZNl7mno <br />mm <br />Zyz�°'� <br />LLWad M <br />¢� <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z fV <br />00)N <br />�°o <br />f� <br />a)M� <br />tn•L� <br />Z <br />a <br />2: (n 0 <br />Q LL <br />00 <br />i�3-Q00 <br />c( <br />E <br />Z M <br />J CD <br />Wko <br />Mill <br />oZ <br />3� <br />w� <br />Za <br />Z <br />i- <br />z <br />airs <br />C <br />Wzj <br />�wz <br />J <br />Lu <br />f <br />J <br />7_i <br />U <br />pJ <br />WOW <br />K O <br />VV W N <br />Z <br />�W© <br />Z <br />Zo <br />li <br />Q U <br />f Z <br />0 <br />w <br />a <br />to 3 <br />fo <br />IM <br />LLJ <br />0 <br />O <br />CU <br />; <br />U <br />a <br />O <br />LL <br />LLJ <br />< <br />�QZo <br />�; aG► <br />o1�0 <br />J.N <br />Z <br />QJU_ Y I~ <br />UOJ <br />�i�m� <br />N <br />zQo� <br />cac <br />G <br />�g <br />Q <br />F- <br />$ago <br />Z <br />N <br />LLI <br />Zo <br />QX Z <br />L U <br />oZ <br />Q <br />Z <br />i290 <br />l0 <br />Z <br />Z <br />a j <br />NZ <br />Z <br />o <br />0 <br />J <br />= <br />- <br />a Z <br />rn <br />,-_4 <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />