Laserfiche WebLink
i <br />-n <br />_ <br />J <br />m <br />LO <br />v <br />0 <br />a <br />0 <br />0 <br />J <br />M <br />CD <br />I <br />m <br />rn <br />u7 <br />L <br />v <br />D- <br />0 <br />a <br />0 <br />0 <br />J <br />rn <br />LO <br />rn <br />0 <br />I <br />v <br />0 <br />0 <br />a <br />CD <br />i <br />a <br />E <br />Cn <br />E <br />0 <br />`v <br />C <br />J <br />co <br />r7 <br />v <br />v <br />5 <br />0 <br />U <br />a <br />Cl- <br />0 <br />U <br />J <br />LZ <br />N <br />0 <br />00 <br />ci <br />0 <br />0 <br />a <br />N <br />0 <br />0 <br />45 <br />0 <br />m <br />0 <br />(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />VENT OR 2ND FLOOR <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />TYPICAL C.M,U. WALL <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE <br />_\ <br />STANDARD 3" DIA. TEE <br />3/4" FURRING STRIPS <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE <br />THREADED 3" DIA. EXTENSION <br />1/2" GYPSUM BOARD <br />CONNECTION <br />SCREW OFF CAP (3" DIA.) <br />W/ DRYWALL SCREWS <br />/ <br />2x DEAD WOOD @ MID <br />FOR CLEAN -OUT <br />@ 8" O.C. OR 4d <br />POINT wl (3)12d <br />DRYWALL NAILS <br />MIN. EXTENSION FROM <br />7 5/8" 8" 7 5/8" 8" <br />SOLID AREAS ARE ❑ <br />G <br />7 5/8" 8" <br />DOUBLE 2x TOP TONEAILS SPACED EXTERIOR FACE OF BLOCK EEI <br />OUPLATE EVENLYWALL IS 1 1/2" MAXIMUM INTERIOR <br />EXTENSION FROM EXTERIOR ❑ ❑ <br />HEADER FLUSH TO OUTSIDE OPTION WALL <br />FACE OF BLOCK WALL IS 2 1/4" <br />BLOCKING @ EACH END W/ 10d @ <br />" O.C. FROM EACH HEADER FACE <br />O BLOCKING <br />WT2x <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1) 10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL 1 <br />SCALE: N.T.S. S4' <br />12 <br />SEE TYPICAL WALL SECTION <br />(TYP) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2) 12d INTO <br />- TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12) 10d <br />(3) 10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />STUD W/ (3) 10d NAILS <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO - - <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />4.7 <br />SIMPSON SP1 w/ (10) 10d <br />NAILS AT EACH STUD • <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERAL NOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />\—ROOFTRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />TO DRAIN DOOR OPENING DOOR OPENING <br />EXTERIOR • ❑ <br />WALL CLEAN -OUT A WALL ❑ ❑ ❑ <br />SCALE: N.T.S. S4 <br />1ST COURSE 2ND COURSE 3RD COURSE <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE <br />SHEETS FOR INSTALLATION INFORMATION BY COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOORJAMB WALL IS TO BE <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />TYPICAL SECTION THRU WINDOW B MASONRY LAYOUT D <br />S4 SCALE: N.T.S. 14 <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/(1)#5 FOR CONCRETE PLACEMENT J <br />a <br />a <br />a <br />a <br />°a a <br />g STD.90'HOOK 8° <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6'-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />O FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />�3 SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO <br />1/2"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR <br />SCRAP MATERIAL BLOCK WALL ABOVE. <br />MOUNTING BASE SHOWN <br />IN POSITION <br />—2x6 MOUNTING BASE <br />a <br />Cr <br />r W <br />o <br />FORM CREATES CONCRETE RECESS TO <br />2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />SCALE: N.T.S. <br />-TRACK MOUNTING BRACKET <br />\ \GARAGE DOOR TRACK <br />SCALE: N.T.S. <br />4 8 a a o <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B E <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />2x CRIPPLES @ — <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" <br />O/C TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />FOP <br />a <br />1ARAGE <br />1OOR <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHE <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1' - 4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />(2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER: <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER • EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6)10d x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />MA <br />00 SIMPSON HTT4 TYP. <br />Op OR U.N.O. SEE N/S4 <br />F, �G ** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL rQ <br />SCALE: N.T.S. S4 <br />SIMPSON SIMPSON <br />SP4 SP2 <br />2X STUDS @ 24" O.C. <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />12 TRUSSES @ 24" 0/C <br />(TYP-) SEE ELEV. UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRIER <br />SIMPSON SP2 w/ (12) 10d <br />NAILS AT EACH STUD <br />TRUSS BOTTOM CHORD OR 2x4 <br />1/2" EXTERIOR GRADE SHEATHING <br />CRICKET AS <br />BLOCKING W/ 2-16d TOE NAILS <br />@ EACH END <br />FASTENED TO TRUSSES WITH 8d <br />REQUIRED <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING ( )Uj <br />O/C FIELD <br />? a <br />2x TOP PLATE <br />— <br />\:2-16d <br />2X4 PT STUDS @ 16" O.C. <br />NAILS @ 24" O.C. OR <br />(2) 2X4 PT STUDS UNDER HIP <br />EQUAL TO TRUSS BOTTOM <br />CARRIER/GIRDER TRUSS <br />_ _ = <br />CHORD OR BLOCKING <br />SIMPSON HETA20 w/ (8) 10dx1 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />2x STUD @ 24" <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />• <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />MOISTURE BARRIER <br />ROOF TRUSS <br />A <br />SEE /S3 FOR <br />STAGGERED FROM BOT. <br />UPLIFT CONNECTOR <br />SEE INFO. <br />PLATE TO CONCRETE <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90' HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />SCALE: N.T.S. <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12) 16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />4B.�PLICE STAGGERED <br />r 41N) <br />C; 10d @ 8" O/C <br />ATTACH ALL <br />EXTERIOR STUDS <br />W/ (4 16d TOENAILS <br />TO P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. <br />F= 2240 LBS �7 <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />I Kill <br />P.T. <br />ATE <br />SIMPSON <br />SP4 —� <br />TRANSOM FRAMING <br />SEE SECTION J/SS <br />AND K/SS FOR <br />ADDITIONAL DETAILS <br />SIMPSON <br />SP2 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />RECESS <br />LINTEL <br />SIMPSON <br />SP1 SIMPSON <br />RECESS SIMPSONSP4 <br />S <br />LINTEL <br />NAILED <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSC <br />SP4 <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL <br />SIMPSON SP4 <br />�2X TOP PLATE <br />OVERLAPPING <br />10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />i (4565# SPF) <br />i (5645# SPF) <br />i (6970# SPF) <br />)S (9335# SPF) <br />PDXIED A.T.R. <br />t & NUT <br />'OXIED A.T.R. <br />2 & NUT <br />OXIED A.T.R. <br />t&NUT <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />2X8 P.T. BOTTOM P ATE G' <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />2X8 P.T. BOTTOM <br />PLATE <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />MASONRY WALL <br />10d NAILS @ 4 10d NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES c E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY rR <br />REV. 06.24.22 <br />SCALE: N.T.S. <br />cN.r <br />e <br />eo <br />N <br />W <br />i L O <br />c r— c <br />® <br />cv <br />C Cv C.a N <br />-- -o m x <br />N%.- <br /><[ N <br />67 <br />N <br />d�a <br />3 CU <br />°�• fl <br />N C <br />E <br />o <br />/7�. <br />) <br />I <br />y°y�> <br />° <br />a <br />` <br />*ice' ,�� <br />) <br />• <br />}} <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications <br />contained within these <br />drawings comply with the 2020 Florida <br />Building Code - <br />Residential <br />7th Edition. Engineers <br />signature and seal is only for <br />the structural <br />engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />a <br />0cE <br />8 <br />��C9 <br />N <br />fH <br />rnnrl_� <br />Q <br />cN2� <br />' S J <br />J LLLU <br />52 <br />J LL p_ <br />/n <br />z <br />--6; Lou Y <br />W <br />L (0 <br />L 0 <br />020,M m <br />T., <br />Lu <br />'n N Z Q <br />ZN <br />O U < c) <br />W <br />ID El <br />o� <br />o <br />� N <br />z � � <br />Q <br />— <br />N <br />z <br />Q) <br />0 s <br />{-, <br />c,-� <br />yy <br />!� <br />W <br />° <br />U <br />O <br />VN <br />c o <br />yes <br />v <br />W J <br />e <br />B <br />I <br />= w ai <br />C.)o F <br />c Y <br />�Q <br />Q N <br />I� <br />o <br />Mz <br />w <br />M <br />o <br />¢ <br />� <br />U_ <br />E <br />z o <br />- <br />> N <br />ao <br />c6 <br />�0 <br />z <br />?o <br />0 a <br />— <br />M� <br />�¢ <br />0° <br />o< <br />O E <br />d <br />¢p <br />¢ <br />a z <br />a <br /><o <br />ww <br />�J <br />(a <br />(n C <br />z$ <br />pY <br />U <br />m� <br />O <br />OLL <br />_ <br />cu <br />m <br />Q W <br />rn <br />3 <br />� <br />UO2 <br />Z 0 <br />QU <br />Q <br />> <br />C> <br /><0 <br />¢ o <br />o <br />w <br /><< <br />�o <br />NJo <br />_< <br />wl <br />a <br />a) <br />J <br />>� <br />ai <br />rn <br />T <br />,--� <br />�c <br />� <br />F <br />L <br />CD <br />Y <br />U) m <br />co <br />N <br />m <br />L^ <br />T <br />O <br />-a 04 <br />N <br />cc N <br />� <br />dam' C) <br />LO <br />r <br />(0 00 <br />r <br />v <br />d' <br />co <br />o <br />z <br />z <br />CD <br />a) <br />a <br />E <br />U � <br />-a 2 <br />Q co <br />v <br />JOB <br />NO : <br />22-09409 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S4 <br />r <br />L <br />w <br />LU <br />V <br />s y <br />i�yyya <br />