Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />10 #14 to lights & outlets <br />NEMA 1 10 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 0 #10 to WH <br />10 #8 to Range <br />#6 to H VAC <br />METER <br />MAOIN <br />50=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />I. Electrical outlet heights as measured from finished floor to center line of the box to be: ito AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />j,4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />IT <br />TELEVISION (OPTIONAL) <br />Tq2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />A IL <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />LP <br />Vv/ NL,. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn nr-n onr7rnn <br />ALI <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />Sv <br />saw <br />cv <br />® <br />CD o <br />ac� o <br />r as c--) C14 <br />m <br />N iO O L <br />y d O fO <br />Q r N <br />.tie <br />co <br />s c> • 3 Cv <br />L <br />f9 � t37 17 <br />' <br />to <br />C <br />C G <br />v <br />L <br />CV <br />CV <br />0 <br />CV <br />O <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />Q <br />0 E <br />O to <br />0' <br />O N o <br />C1 'D n <br />O N <br />N <br />7 O <br />cn�t,_� <br />N <br />Q <br />13W <br />0 <br />M V x# LL <br />C J W <br />J ,y LL a <br />a <br />Z <br />��rn <br />�. <br />L (0 5 Z zi <br />j 'M N C; O O <br />W <br />��pj6' <br />MLLI <br />z <br />m <br />co Mz< <br />Z <br />N 0 U <br />0 <br />< <br />W <br />❑ El <br />M � <br />Z N M <br />o g <br />z N <br />z o � <br />� <br />Q <br />J <br />O <br />13 <br />U)L,l <br />N <br />LU <br />U <br />O <br />�N <br />c� <br />_ m E <br />t <br />zip <br />_ <br />C) o y <br />c <br />0 <br />o <br />o ® <br />o <br />� <br />w <br />co <br />03Y <br />z <br />a <br />� <br />E <br />Q <br />E oCU <br />W O <br />z <br />Q N <br />ZQ <br />Zo <br />F— <br />x <br />0¢ <br />¢� <br />� 0 <br />On, <br />o Q <br />ww <br />(V <br />N L <br />.0 <br />% <br />o, <br />cn C: <br />0Y <br />m � <br />a <br />a� <br />H <br />ZCIO <br />Z� <br />J <br />�z <br />a <br /><� <br />�Z <br />a � <br />8< <br />W <br />of <br />OCD <br />a <br />J <br />< ¢ <br />c O <br />O <br />-4- <br />6L, <br />zla <br />a <br />� 3 <br />2 O <br />0 <br />i <br />C.0 <br />J <br />LO <br />'-n <br />°' <br />tT <br />�\ <br />a <br />ca <br />=3 C <br />Q <br />Ycc <br />T <br />m <br />/� <br />L <br />r <br />a)N <br />Q <br />0 <br />I <br />O <br />CV <br />W C) <br />LO <br />r <br />LO oo <br />r <br />ai <br />E <br />w <br />M <br />ri <br />o <br />z <br />(6 <br />Z <br />E O <br />a <br />0 <br />Q o <br />JOB <br />NO: <br />22-09409 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />.i, i-i1�- ui. V L.�i�1➢iiul!ui_i�.ia.m r i ri:_:; �.: i <br />