Laserfiche WebLink
0 <br />0 <br />ROOF PLAN <br />SCALE: 1 /4"=1'-0" <br />LOWER ROOF ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />120 SQ. FT. <br />1 15 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF. <br />1 18 LF. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />UPPER ROOF ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />1611 SQ. FT. <br />773 SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />309 SQ. IN. <br />UPPER VENT 50% NET VENT MAX. <br />387 SQ. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />3 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />414 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />414 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF. <br />63 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905.1.1 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2' <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />® <br />i <br />t4O <br />a d <br />�a '. <br />AT OF <br />.o ° <br />C. <br />IY <br />w <br />C,JF—CC <br />wZO <br />� <br />wZ0 <br />w <br />>oCQO <br />c)Uww <br />Q�WI-- <br />_ <br />J <br />> <br />IY fY cr_ <br />Y 0 F— Z <br />�LL00_� <br />ZZZF—w_ <br />�g¢< J <br />w0..=Iia, <br />_jc)000 <br />Z:)—ZLL(n <br />QZ� <br />r` <br />�CZ ¢� <br />Ir <br />O L j <br />FF_ <br />2 <br />0 <br />0 <br />r� <br />V <br />Z <br />O <br />Im <br />Lo <br />a <br />`-1 <br />LLO <br />0 <br />O <br />LL <br />i� <br />O <br />O <br />U) <br />w <br />w <br />0 <br />x <br />z <br />0 <br />En <br />W <br />0 <br />z <br />Z <br />o� <br />�o <br />Z' <br />a <br />a <br />a <br />a <br />a <br />t <br />^s <br />2022 <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6103 <br />RELEASED: 1 / 1 4/22 <br />SHEET <br />A3. I <br />