DWELLING -GARAGE SEPARATION:
<br />R302.5 DWELLING -GARAGE OPENING AND PENETRATION PROTECTION
<br />OPENINGS AND PENETRATIONS THROUGH THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM
<br />THE GARAGE SHALL BE IN ACCORDANCE WITH SECTIONS R302.5.1 THROUGH R302.5.3.
<br />R302.5.1 OPENING PROTECTION
<br />OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL
<br />NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED
<br />WITH SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES (35 MM) IN THICKNESS, SOLID OR
<br />HONEYCOMBCORE STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR 20-MINUTE FIRE -RATED
<br />DOORS.
<br />R302.6 DWELLING -GARAGE FIRE SEPARATION
<br />THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL
<br />COMPLY WITH SECTION R302.5. ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702.3.5.
<br />THE WALL SEPARATION PROVISIONS OF TABLE R302.6 SHALL NOT APPLY TO GARAGE WALLS THAT ARE
<br />PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL.
<br />TABLE R302.6 DWELLING -GARAGE SEPARATION
<br />FROM THE RESIDENCE AND ATTICS
<br />NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE
<br />FROM HABITABLE ROOMS ABOVE THE GARAGE
<br />NOT LESS THAN 5/8-INCH TYPE X GYPSUM BOARD OR EQUIVALENT
<br />STRUCTURE(S) SUPPORTING FLOOR/CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS
<br />SECTION
<br />NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT
<br />R302.7 UNDER -STAIR PROTECTION
<br />ENCLOSED SPACE UNDER STAIRS THAT IS ACCESSED BY A DOOR OR ACCESS PANEL SHALL HAVE WALLS,
<br />UNDER -STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2-INCH (12.7 MM)
<br />GYPSUM BOARD.
<br />FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX:
<br />R302.9 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR WALL AND CEILING FINISHES
<br />FLAME SPREAD AND SMOKE -DEVELOPED INDEXES FOR WALL AND CEILING FINISHES SHALL BE IN
<br />ACCORDANCE WITH SECTIONS R302.9.1 THROUGH R302.9.4.
<br />R302.10 FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX FOR INSULATION
<br />FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH
<br />SECTIONS R302.10.1 THROUGH R302.10.5.
<br />FIREBLOCKING:
<br />R302.11 FIREBLOCKING
<br />IN COMBUSTIBLE CONSTRUCTION, FIREBLOCKING SHALL BE PROVIDED TO CUT OFF BOTH VERTICAL AND
<br />HORIZONTAL CONCEALED DRAFT OPENINGS AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN
<br />STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE.
<br />FIREBLOCKING SHALL BE PROVIDED IN WOOD -FRAMED CONSTRUCTION IN THE FOLLOWING LOCATIONS:
<br />1 . IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND
<br />PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS:
<br />I.I.VERTICALLY AT THE CEILING AND FLOOR LEVELS.
<br />1.2.HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET (3048 MM).
<br />2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS
<br />OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS.
<br />3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN.
<br />ENCLOSED SPACES UNDER STAIRS SHALL COMPLY WITH SECTION R302.7.
<br />4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL,
<br />WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF
<br />COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE REQUIRED TO MEET THE ASTM
<br />E136 REQUIREMENTS.
<br />5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003-19.
<br />6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING
<br />UNIT SEPARATION.
<br />R302.11.1 FIREBLOCKING MATERIALS
<br />EXCEPT AS PROVIDED IN SECTION R302.1 1, ITEM 4, FIREBLOCKING SHALL CONSIST OF THE FOLLOWING
<br />MATERIALS.
<br />1 . TWO-INCH (51 MM) NOMINAL LUMBER.
<br />2. TWO THICKNESSES OF 1 -INCH (25.4 MM) NOMINAL LUMBER WITH BROKEN LAP JOINTS.
<br />3. ONE THICKNESS OF 23/32-INCH (18.3 MM) WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY
<br />23/32-INCH (18.3 MM) WOOD STRUCTURAL PANELS.
<br />4. ONE THICKNESS OF 3/4-INCH (19.1 MM) PARTICLEBOARD WITH JOINTS BACKED BY 3/4-INCH (19.1 MM)
<br />PARTICLEBOARD.
<br />5. ONE -HALF -INCH (12.7 MM) GYPSUM BOARD.
<br />6. ONE -QUARTER -INCH (6.4 MM) CEMENT -BASED MILLBOARD.
<br />7. BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER OR OTHER APPROVED MATERIALS
<br />INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE.
<br />8. CELLULOSE INSULATION INSTALLED AS TESTED IN ACCORDANCE WITH ASTM El 19 OR UL 263, FOR
<br />THE SPECIFIC APPLICATION.
<br />R302.12 DRAFTSTOPPING
<br />IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE
<br />CONCEALED SPACE OF A FLOOR -CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE
<br />AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 M2). DRAFTSTOPPING
<br />SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS
<br />ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL
<br />BE PROVIDED IN FLOOR -CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES:
<br />1.CEILING IS SUSPENDED UNDER THE FLOOR FRAMING.
<br />2.FLOOR FRAMING IS CONSTRUCTED OF TRUSS -TYPE OPEN -WEB OR PERFORATED MEMBERS.
<br />R302.12.1 MATERIALS
<br />DRAFTSTOPPING MATERIALS SHALL BE NOT LESS THAN 1/2-INCH (12.7 MM) GYPSUM BOARD, 3/8-INCH (9.5
<br />MM) WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
<br />DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBERS UNLESS
<br />OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE
<br />MAINTAINED.
<br />HAZARDOUS LOCATIONS:
<br />R308.4.1 GLAZING IN DOORS
<br />GLAZING IN FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS SHALL BE
<br />CONSIDERED TO BE A HAZARDOUS LOCATION.
<br />EXCEPTIONS:
<br />1 . GLAZED OPENINGS OF A SIZE THROUGH WHICH A 3-INCH-DIAMETER SPHERE IS UNABLE TO PASS.
<br />2. DECORATIVE GLAZING
<br />R308.4.2 GLAZING ADJACENT TO DOORS.
<br />GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR SHALL BE CONSIDERED TO
<br />BE A HAZARDOUS LOCATION WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60
<br />INCHES ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING
<br />CONDITIONS:
<br />1 . WHERE THE GLAZING IS WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IN THE PLANE OF THE
<br />DOOR IN A CLOSED POSITION.
<br />2. WHERE THE GLAZING IS ON A WALL LESS THAN 180 DEGREES FROM THE PLANE OF THE DOOR IN A
<br />CLOSED POSITION AND WITHIN 24 INCHES OF THE HINGE SIDE OF AN IN -SWINGING DOOR.
<br />EXCEPTIONS:
<br />1 . DECORATIVE GLAZING.
<br />2. WHERE THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE DOOR
<br />AND THE GLAZING.
<br />3. WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN
<br />DEPTH. GLAZING IN THIS APPLICATION SHALL COMPLY WITH SECTION R308.4.3.
<br />4. GLAZING THAT IS ADJACENT TO THE FIXED PANEL OF PATIO DOORS.
<br />GENERAL CONSTRUCTION NOTES
<br />R308.4.3 GLAZING IN WINDOWS
<br />GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS
<br />SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION:
<br />1 . THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN 9 SQUARE FEET,
<br />2. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18 INCHES ABOVE THE FLOOR,
<br />3. THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES ABOVE THE FLOOR; AND
<br />4. ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES,
<br />5. MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING.
<br />R308.4.5 GLAZING AND WET SURFACES
<br />GLAZING IN WALLS, ENCLOSURES OR FENCES CONTAINING OR FACING HOT TUBS, SPAS, WHIRLPOOLS,
<br />SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR OUTDOOR SWIMMING POOLS WHERE
<br />THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE
<br />ANY STANDING OR WALKING SURFACE SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. THIS
<br />SHALL APPLY TO SINGLE GLAZING AND EACH PANE IN MULTIPLE GLAZING.
<br />EXCEPTION: GLAZING THAT IS MORE THAN 60 INCHES, MEASURED HORIZONTALLY AND IN A STRAIGHT
<br />LINE, FROM THE WATER'S EDGE OF A BATHTUB, HOT TUB, SPA, WHIRLPOOL OR SWIMMING POOL OR FROM
<br />THE EDGE OF A SHOWER, SAUNA OR STEAM ROOM.
<br />R308.4.6 GLAZING ADJACENT TO STAIRS AND RAMPS
<br />GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE
<br />PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN FLIGHTS OF STAIRS
<br />AND RAMPS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION.
<br />R308.4.7 GLAZING ADJACENT TO THE BOTTOM STAIR LANDING
<br />GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS LESS
<br />THAN 36 INCHES ABOVE THE LANDING AND WITHIN A 60-INCH HORIZONTAL ARC LESS THAN 180 DEGREES
<br />FROM THE BOTTOM TREAD NOSING SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION.
<br />GARAGES:
<br />R309.1 FLOOR SURFACE
<br />GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.
<br />THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO
<br />FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY.
<br />R310.2.1 MINIMUM OPENING AREA
<br />EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7
<br />SQUARE FEET. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES AND THE NET
<br />CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES.
<br />EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT
<br />LESS THAN 5 SQUARE FEET.
<br />R310.2.2 WINDOW SILL HEIGHT
<br />WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND RESCUE OPENING, IT SHALL HAVE A
<br />SILL HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR.
<br />R31 0.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES
<br />EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM
<br />WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROL DEVICES
<br />COMPLYING WITH ASTM F2090 SHALL BE PERMITTED FOR USE ON WINDOWS SERVING AS A REQUIRED
<br />EMERGENCY ESCAPE AND RESCUE OPENING.
<br />R312.2.1 WINDOW SILLS
<br />IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS
<br />THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES (1829 MM) ABOVE
<br />THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE
<br />WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING:
<br />1 . OPERABLE WINDOWS WITH OPENINGS THAT WILL NOT ALLOW A 4-INCH-DIAMETER (102 MM) SPHERE
<br />TO PASS THROUGH THE OPENING WHERE THE OPENING IS IN ITS LARGEST OPENED POSITION.
<br />2. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT
<br />COMPLY WITH ASTM F2090.
<br />3. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT
<br />COMPLY WITH SECTION R312.2.2.
<br />STAIRWAYS:
<br />R311.7.1 WIDTH
<br />STAIRWAYS SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN CLEAR WIDTH AT ALL POINTS ABOVE THE
<br />PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. THE CLEAR WIDTH OF
<br />THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL BE NOT
<br />LESS THAN 311/2 INCHES (787 MM) WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27 INCHES (698
<br />MM) WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES.
<br />R311.7.2 HEADROOM
<br />THE HEADROOM IN STAIRWAYS SHALL BE NOT LESS THAN 6 FEET 8 INCHES (2032 MM) MEASURED
<br />VERTICALLY FROM THE SLOPED LINE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF
<br />THE LANDING OR PLATFORM ON THAT PORTION OF THE STAIRWAY.
<br />R311.7.5 STAIR TREADS AND RISERS
<br />STAIR TREADS AND RISERS SHALL MEET THE REQUIREMENTS OF THIS SECTION. FOR THE PURPOSES OF
<br />THIS SECTION, DIMENSIONS AND DIMENSIONED SURFACES SHALL BE EXCLUSIVE OF CARPETS, RUGS OR
<br />RUNNERS.
<br />R311.7.5.1 RISERS
<br />THE RISER HEIGHT SHALL BE NOT MORE THAN 73/4 INCHES (196 MM). THE RISER SHALL BE MEASURED
<br />VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT
<br />WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5 MM).
<br />RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING OF THE TREAD ABOVE AT
<br />AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED
<br />PROVIDED THAT THE OPENINGS LOCATED MORE THAN 30 INCHES (762 MM), AS MEASURED VERTICALLY,
<br />TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM)
<br />SPHERE.
<br />R311.7.5.2 TREADS
<br />THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE
<br />MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF
<br />ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD
<br />DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH (9.5
<br />MM).
<br />R311.7.5.3 NOSINGS
<br />NOSINGS AT TREADS, LANDINGS AND FLOORS OF STAIRWAYS SHALL HAVE A RADIUS OF CURVATURE AT
<br />THE NOSING NOT GREATER THAN 9/16 INCH (14 MM) OR A BEVEL NOT EXCEEDING 1/2 INCH (12.7 MM). A
<br />NOSING PROJECTION NOT LESS THAN 3/4 INCH (19 MM) AND NOT MORE THAN 11/4 INCHES (32 MM) SHALL
<br />BE PROVIDED ON STAIRWAYS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST
<br />NOSING PROJECTION BY MORE THAN 3/8 INCH (9.5 MM) WITHIN A STAIRWAY.
<br />EXCEPTION: A NOSING PROJECTION IS NOT REQUIRED WHERE THE TREAD DEPTH IS NOT LESS THAN 11
<br />INCHES (279 MM).
<br />R311.7.8 HANDRAILS
<br />HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH FLIGHT WITH FOUR OR MORE
<br />RISERS.
<br />R311.7.8.1 HEIGHT
<br />HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING,
<br />OR FINISH SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE
<br />THAN 38 INCHES (965 MM).
<br />EXCEPTIONS:
<br />1 . THE USE OF A VOLUTE, TURNOUT OR STARTING EASING SHALL BE ALLOWED OVER THE LOWEST
<br />TREAD.
<br />2. WHERE HANDRAIL FITTINGS OR BENDINGS ARE USED TO PROVIDE CONTINUOUS TRANSITION
<br />BETWEEN FLIGHTS, TRANSITIONS AT WINDER TREADS, THE TRANSITION FROM HANDRAIL TO GUARD, OR
<br />USED AT THE START OF A FLIGHT, THE HANDRAIL HEIGHT AT THE FITTINGS OR BENDINGS SHALL BE
<br />PERMITTED TO EXCEED 38 INCHES (956 MM).
<br />R311.7.8.2 CONTINUITY
<br />HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A
<br />POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER
<br />OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR
<br />SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 11/2
<br />INCHES (38 MM) BETWEEN THE WALL AND THE HANDRAILS.
<br />EXCEPTIONS:
<br />1 . HANDRAILS SHALL BE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AT THE TURN.
<br />2. THE USE OF A VOLUTE, TURNOUT, STARTING EASING OR STARTING NEWEL SHALL BE ALLOWED
<br />OVER THE LOWEST TREAD.
<br />R311.7.8.3 GRIP -SIZE
<br />REQUIRED HANDRAILS SHALL BE OF ONE OF THE FOLLOWING TYPES OR PROVIDE EQUIVALENT
<br />GRASPABILITY.
<br />1. TYPE 1. HANDRAiLS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF NOT
<br />LESS THAN 11/4 INCHES (32 MM) AND NOT GREATER THAN 2 INCHES (51 MM). IF THE HANDRAIL IS NOT
<br />CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF NOT LESS THAN 4 INCHES (102 MM) AND NOT
<br />GREATER THAN 61/4 INCHES (160 MM) WITH A CROSS SECTION OF DIMENSION OF NOT MORE THAN 21/4
<br />INCHES (57 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01 INCH (0.25 MM).
<br />2. TYPE 11. HANDRAILS WITH A PERIMETER GREATER THAN 61/4 INCHES (160 MM) SHALL HAVE A
<br />GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. THE FINGER RECESS SHALL BEGIN
<br />WITHIN A DISTANCE OF 3/4 INCH (19 MM) MEASURED VERTICALLY FROM THE TALLEST PORTION OF THE
<br />PROFILE AND ACHIEVE A DEPTH OF NOT LESS THAN 5/16 INCH (8 MM) WITHIN 7/8 INCH (22 MM) BELOW THE
<br />WIDEST PORTION OF THE PROFILE. THIS REQUIRED DEPTH SHALL CONTINUE FOR NOT LESS THAN 3/8
<br />INCH (10 MM) TO A LEVEL THAT IS NOT LESS THAN 13/4 INCHES (45 MM) BELOW THE TALLEST PORTION OF
<br />THE PROFILE. THE WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE NOT LESS THAN 11/4 INCHES
<br />(32 MM) AND NOT MORE THAN 23/4 INCHES (70 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01
<br />INCH (0.25 MM).
<br />f%_llA0n42-
<br />R312.1.1 WHERE REQUIRED
<br />GUARDS SHALL BE PROVIDED FOR THOSE PORTIONS OF OPEN -SIDED WALKING SURFACES, INCLUDING
<br />STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED
<br />VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 24 INCHES (610 MM) HORIZONTALLY
<br />TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD.
<br />R312.1.2 HEIGHT
<br />REQUIRED GUARDS AT OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR
<br />LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS MEASURED VERTICALLY ABOVE
<br />THE ADJACENT WALKING SURFACE OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS.
<br />EXCEPTIONS:
<br />1 . GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES (864 MM)
<br />MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS.
<br />2. WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP
<br />OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM)
<br />AS MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS.
<br />R312.1.3 OPENING LIMITATIONS
<br />REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED
<br />GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER.
<br />EXCEPTIONS:
<br />1 . THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR, FORMED BY THE RISER, TREAD AND
<br />BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (153 MM) IN DIAMETER.
<br />2. GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A
<br />SPHERE 43/8 INCHES (111 MM) IN DIAMETER.
<br />CONCRETE FLOORS:
<br />R506.2.3 VAPOR RETARDER
<br />A 6-MIL (0.006 INCH; 152 MM) POLYETHYLENE OR APPROVED VAPOR RETARDER WITH JOINTS LAPPED NOT
<br />LESS THAN 6 INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND THE BASE
<br />COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS.
<br />EXCEPTION: THE VAPOR RETARDER IS NOT REQUIRED FOR THE FOLLOWING:
<br />1 . GARAGES, UTILITY BUILDINGS AND OTHER UNHEATED ACCESSORY STRUCTURES.
<br />2. FOR UNHEATED STORAGE ROOMS HAVING AN AREA OF LESS THAN 70 SQUARE FEET (6.5 M2) AND
<br />CARPORTS.
<br />3. DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK NOT LIKELY TO BE ENCLOSED AND HEATED AT
<br />A LATER DATE.
<br />4. WHERE APPROVED BY THE BUILDING OFFICIAL, BASED ON LOCAL SITE CONDITIONS.
<br />WALL COVERING:
<br />R702.4.2 BACKER BOARDS
<br />MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN
<br />SHOWER AREAS SHALL BE OF MATERIALS LISTED IN TABLE R702.4.2, AND INSTALLED IN ACCORDANCE
<br />WITH THE MANUFACTUREROS RECOMMENDATIONS.
<br />TABLE R702.4.2BACKER BOARD MATERIALS
<br />GLASS MAT GYPSUM BACKING PANEL (ASTM Cl 178)
<br />FIBER -REINFORCED GYPSUM PANELS (ASTM C1278)
<br />NONASBESTOS FIBER -CEMENT BACKER BOARD (ASTM C1288 OR ISO 8336, CATEGORY C)
<br />NONASBESTOS FIBER MAT REINFORCED CEMENTITIOUS BACKER UNITS (ASTM C1325)
<br />WINDOW INSTALLATION
<br />WINDOWS SHALL BE INSTALLED AND FLASHED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN
<br />INSTALLATION INSTRUCTIONS. WRITTEN INSTALLATION INSTRUCTIONS SHALL BE PROVIDED BY THE
<br />MANUFACTURER FOR EACH WINDOW.
<br />R703.4 FLASHING
<br />APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED MEMBRANES AND MECHANICALLY
<br />ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED SHINGLE -FASHION OR IN ACCORDANCE WITH THE
<br />MANUFACTURER'S INSTRUCTIONS. METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED
<br />MEMBRANES USED AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S
<br />INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE ENTRY OF WATER INTO
<br />THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS.
<br />SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR
<br />FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A
<br />SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER
<br />JOINT EXPANSION AND CONTRACTION, ASTM Cl 281, AAMA 812, OR OTHER APPROVED STANDARD AS
<br />APPROPRIATE FOR THE TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR
<br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE
<br />EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS:
<br />l.EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS
<br />SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER
<br />COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE
<br />FLASHINGS SHALL COMPLY WITH AAMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS
<br />SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING:
<br />1.1. THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR
<br />APPLICATIONS NOT ADDRESSED IN THE FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN
<br />ACCORDANCE WITH THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS
<br />OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW
<br />AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT
<br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR
<br />SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR
<br />PROTECTION AT THE HEAD AND SIDES.
<br />1.2. IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN
<br />PROFESSIONAL.
<br />1.3. IN ACCORDANCE WITH OTHER APPROVED METHODS.
<br />1.4. IN ACCORDANCE WITH FMAJAAMA 100, FMA/AAMA 200, FMA/WDMA 250, FMA/AAMA/WDMA 300 OR
<br />FMA/AAMA/WDMA 400.
<br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR
<br />STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS.
<br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS.
<br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM.
<br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF
<br />WOOD -FRAME CONSTRUCTION.
<br />6. AT WALL AND ROOF INTERSECTIONS.
<br />ROOF ASSEMBLIES:
<br />R903.2 FLASHING
<br />FLASHINGS SHALL BE USED TO SEAL ROOFING SYSTEMS, WHERE THE SYSTEM IS INTERRUPTED OR
<br />TERMINATED AND SHALL BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING THE WALL
<br />AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS AND AT
<br />INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE.
<br />R903.2.1 LOCATIONS
<br />FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN
<br />ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL
<br />SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN PROVIDED IN TABLE R903.2.1 OR IN
<br />COMPLIANCE WITH RAS 111.
<br />EXCEPTION: FLASHING IS NOT REQUIRED AT HIP AND RIDGE JUNCTIONS.
<br />R903.2.3 MEMBRANE FLASHINGS
<br />ALL MEMBRANE FLASHING SHALL BE INSTALLED ACCORDING TO THE ROOF ASSEMBLY MANUFACTURER'S
<br />PUBLISHED LITERATURE.
<br />R905.1.1.1 UNDERLAYMENT FOR ASPHALT, METAL, MINERAL SURFACED, SLATE AND SLATE -TYPE ROOF
<br />COVERINGS
<br />UNDERLAYMENT FOR ASPHALT SHINGLES, METAL ROOF SHINGLES, MINERAL SURFACED ROLL ROOFING,
<br />SLATE AND SLATE -TYPE SHINGLES, AND METAL ROOF PANELS SHALL COMPLY WITH ONE OF THE FOLLOWING
<br />METHODS:
<br />4. TWO LAYERS OF ASTM D226 TYPE 11 OR ASTM D4869 TYPE III OR TYPE IV UNDERLAYMENT SHALL BE
<br />INSTALLED AS FOLLOWS: APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT FELT PARALLEL TO AND
<br />STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY
<br />36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT, OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM);
<br />END LAPS SHALL BE 6 INCHES AND SHALL BE OFFSET BY 6 FEET. THE UNDERLAYMENT SHALL BE ATTACHED
<br />TO A NAILABLE DECK WITH CORROSION -RESISTANT FASTENERS WITH ONE ROW CENTERED IN THE FIELD OF
<br />THE SHEET WITH A MAXIMUM FASTENER SPACING OF 12 INCHES (305 MM) O.C., AND ONE ROW AT THE END
<br />AND SIDE LAPS FASTENED 6 INCHES (152 MM) O.C.
<br />5. TWO LAYERS OF A REINFORCED SYNTHETIC UNDERLAYMENT THAT HAS A PRODUCT APPROVAL AS AN
<br />ALTERNATIVE TO UNDERLAYMENT COMPLYING WITH ASTM D226 TYPE 11 SHALL BE PERMITTED TO BE USED.
<br />SYNTHETIC UNDERLAYMENT SHALL HAVE A MINIMUM TEAR STRENGTH OF 15 LBF IN ACCORDANCE WITH ASTM
<br />D4533 AND A MINIMUM TENSILE STRENGTH OF 20 LBF/INCH IN ACCORDANCE WITH ASTM D5035, AND SHALL
<br />MEET THE LIQUID WATER TRANSMISSION TEST OF SECTION 8.6 OF ASTM D4869. SYNTHETIC UNDERLAYMENT
<br />SHALL BE INSTALLED AS FOLLOWS: APPLY A STRIP OF SYNTHETIC UNDERLAYMENT THAT IS HALF THE WIDTH
<br />OF A FULL SHEET PARALLEL TO AND STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE.
<br />STARTING AT THE EAVE, APPLY FULL SHEETS OF REINFORCED SYNTHETIC UNDERLAYMENT, OVERLAPPING
<br />SUCCESSIVE SHEETS HALF THE WIDTH OF A FULL SHEET PLUS THE WIDTH OF THE MANUFACTURER'S
<br />SINGLE -PLY OVIERLAP. END LAPS SHALL BE 6 INCHES AND SHALL BE OFFSET BY 6 FEET. SYNTHETIC
<br />UNDERLAYMENT SHALL BE ATTACHED TO A NAILABLE DECK WITH CORROSION -RESISTANT FASTENERS WITH A
<br />MAXIMUM FASTENER SPACING, MEASURED HORIZONTALLY AND VERTICALLY, OF 12 INCHES (305 MM) O.C.
<br />BETWEEN SIDE LAPS, AND ONE ROW AT THE END AND SIDE LAPS FASTENED 6 INCHES (152 MM) O.C.
<br />UNDERLAYMENT SHALL BE ATTACHED USING ANNULAR RING OR DEFORMED SHANK NAILS WITH METAL OR
<br />PLASTIC CAPS WITH A NOMINAL CAP DIAMETER OF NOT LESS THAN I INCH. METAL CAPS ARE REQUIRED
<br />WHERE THE ULTIMATE DESIGN WIND SPEED, VULT, EQUALS OR EXCEEDS 170 MPH. METAL CAPS SHALL HAVE
<br />A THICKNESS OF NOT LESS THAN 32-GAGE SHEET METAL. POWER -DRIVEN METAL CAPS SHALL HAVE A
<br />MINIMUM THICKNESS OF 0.010 INCH. MINIMUM THICKNESS OF THE OUTSIDE EDGE OF PLASTIC CAPS SHALL BE
<br />0.035 INCH. THE CAP NAIL SHANK SHALL BE NOT LESS THAN 0.083 INCH FOR RING SHANK CAP NAILS. CAP NAIL
<br />SHANK SHALL HAVE A LENGTH SUFFICIENT TO PENETRATE THROUGH THE ROOF SHEATHING OR NOT LESS
<br />THAN 3/4 INCH INTO THE ROOF SHEATHING.
<br />R905.2.4.1 WIND RESISTANCE OF ASPHALT SHINGLES (IF APPLICABLE)
<br />ASPHALT SHINGLES SHALL BE INSTALLED IN ACCORDANCE WITH SECTIONS R905.2.6 AND R905.2.6.1.
<br />R905.3 CLAY AND CONCRETE TILE
<br />THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
<br />INSTALLATION INSTRUCTIONS, OR RECOMMENDATIONS OF FRSArrRI FLORIDA HIGH WIND CONCRETE AND
<br />CLAY ROOF TILE INSTALLATION MANUAL, SIXTH EDITION WHERE THE VASD IS DETERMINED IN ACCORDANCE
<br />WITH SECTION R301.2.1.3 OR THE RECOMMENDATIONS OF RAS 118,119 OR 120.
<br />EXHAUST SYSTEMS:
<br />M1501.1 OUTDOOR DISCHARGE
<br />THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS IN
<br />ACCORDANCE WITH SECTION Ml 506.3. AIR SHALL NOT BE EXHAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT OR
<br />CRAWL SPACE.
<br />M1502.4.5 DRYER DUCT LENGTH
<br />THE MAXIMUM ALLOWABLE EXHAUST DUCT LENGTH SHALL BE DETERMINED BY ONE OF THE METHODS
<br />SPECIFIED IN SECTIONS M1502.4.5.1 THROUGH M1502.4.5.3.
<br />M1502.4.5.1 SPECIFIED LENGTH
<br />THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE 35 FEET (10 668 MM) FROM THE CONNECTION TO THE
<br />TRANSITION DUCT FROM THE DRYER TO THE OUTLET TERMINAL. WHERE FITTINGS ARE USED, THE MAXIMUM
<br />LENGTH OF THE EXHAUST DUCT SHALL BE REDUCED IN ACCORDANCE WITH TABLE M1502.4.5.1. THE MAXIMUM
<br />LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT.
<br />M1502.4.5.2 MANUFACTURER'S INSTRUCTIONS
<br />THE SIZE AND MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE DETERMINED BY THE DRYER
<br />MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE CODE OFFICIAL SHALL BE PROVIDED WITH A COPY OF
<br />THE INSTALLATION INSTRUCTIONS FOR THE MAKE AND MODEL OF THE DRYER AT THE CONCEALMENT
<br />INSPECTION. IN THE ABSENCE OF FITTING EQUIVALENT LENGTH CALCULATIONS FROM THE CLOTHES DRYER
<br />MANUFACTURER, TABLE Ml 502.4.5.1 SHALL BE USED.
<br />M1502.4.5.3 DRYER EXHAUST DUCT POWER VENTILATOR
<br />THE MAXIMUM LENGTH OF THE EXHAUST DUCT SHALL BE DETERMINED IN ACCORDANCE WITH THE
<br />MANUFACTURER'S INSTRUCTIONS FOR THE DRYER EXHAUST DUCT POWER VENTILATOR.
<br />GENERAL NOTES:
<br />ATTENTION GENERAL CONTRACTOR / BUILDER:
<br />ISSUANCE OF PLANS FROM THE ARCHITECT SHALL NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW
<br />AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO APPLICABLE BUILDING CODES PRIOR TO
<br />COMMENCEMENT OF ANY CONSTRUCTION. ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR
<br />ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
<br />FOR CORRECTION BEFORE COMMENCEMENT OF ANY CONSTRUCTION CORRECTION / REVISIONS. ANY
<br />REVISIONS OR CHANGES, NOT RELATED TO THE CORRECTION OF ERRORS THAT ARE MADE AFTER THE FINAL
<br />PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT TO ADDITIONAL FEES. IF ANY MODIFICATIONS ARE MADE
<br />TO THESE PLANS BY ANY OTHER PARTY OTHER THAN THE ARCHITECT, THE ARCHITECT SHALL NOT BE HELD
<br />RESPONSIBLE.
<br />INSPECTION NOTES:
<br />WORK SHALL NOT BE DONE BEYOND THE POINT INDICATED IN EACH SUCCESSIVE INSPECTION WITHOUT FIRST
<br />OBTAINING THE APPROVAL OF THE BUILDING OFFICIAL. THE BUILDING OFFICIAL, UPON NOTIFICATION, SHALL
<br />MAKE THE REQUESTED INSPECTIONS AND SHALL EITHER INDICATE THE PORTION OF THE CONSTRUCTION
<br />THAT IS SATISFACTORY AS COMPLETED, OR NOTIFY THE PERMIT HOLDER OR HIS OR HER AGENT WHEREIN
<br />THE SAME FAILS TO COMPLY WITH THIS CODE. ANY PORTIONS THAT DO NOT COMPLY SHALL BE CORRECTED
<br />AND SUCH PORTION SHALL NOT BE COVERED OR CONCEALED UNTIL AUTHORIZED BY THE BUILDING OFFICIAL.
<br />FOUNDATION INSPECTION NOTES:
<br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE FOR THE
<br />BUILDING INSPECTOR'S USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED
<br />FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS.
<br />EXTERIOR FINISHES:
<br />1 . CEMENT PLASTER FINISH OVER MASONRY SHALL BE 5/8" THICK TEXTURED PER COMMUNITY
<br />STANDARDS.
<br />2. CEMENT PLASTER FINISH OVER WOOD SUBSTRATE SHALL BE 7/8- THICK (3) COAT STUCCO OVER (2)
<br />LAYERS OF WATER RESISTANT BARRIERS IN ACCORDANCE WITH FLORIDA BUILDING CODE 7TH EDITION (20,S)
<br />RESIDENTIAL, R703 AND ASTM C926. TEXTURE PER COMMUNITY
<br />FLOOD ZONE REQUIREMENTS:
<br />PLAN MEETS OR EXCEEDS FEMA FLOOD FINISHED GARAGE FLOOR ELEVATION.
<br />MECHANICAL AND HVAC:
<br />1 . ENERGY CALCULATIONS FOR HEATING AND COOLING CAPACITIES SHALL BE FURNISHED BY THE
<br />GENERAL CONTRACTOR AS AN ATTACHMENT TO THIS PLAN SET AT THE TIME OF APPLICATION FOR PERMIT.
<br />2. MECHANICAL APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, REPAIR, AND
<br />REPLACEMENT WITHOUT REMOVING PERMANENT CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER
<br />PIPING OR DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED, OR
<br />REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES (762 mm) DEEP AND 30 INCHES (762 mm) WIDE
<br />SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.
<br />3. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING
<br />FROM THE GARAGE SHALL BE CONSTRUCTED OF A MIN. #26 GAUGE (0.48 mm) SHEET STEEL OR OTHER
<br />APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE.
<br />4. FOUNDATIONS AND SUPPORTS FOR OUTDOOR MECHANICAL SYSTEMS SHALL BE RAISED AT LEAST 3
<br />INCHES (76 mm) ABOVE THE FINISHED GRADE AND SHALL ALSO CONFORM TO THE MANUFACTURER'S
<br />INSTALLATION INSTRUCTIONS.
<br />5. AUXILIARY DRAIN PAN. CATEGORY IV CONDENSING APPLIANCES SHALL BE PROVIDED WITH AN
<br />AUXILIARY DRAIN PAN WHERE DAMAGE TO ANY BUILDING COMPONENT WILL OCCUR AS A RESULT OF
<br />STOPPAGE IN THE CONDENSATE DRAIN PIPING SYSTEM. THESE PANS SHALL BE INSTALLED IN ACCORDANCE
<br />WITH THE APPLICABLE PROVISIONS OF SECTIONS M1411.3.
<br />�10
<br />�o
<br />L
<br />cr-
<br />LLI I
<br />Lu z o m
<br />3: 0 >_
<br />Lu LU Z 0
<br />> cr < 0
<br />W cl F-
<br />EE III o
<br />U) 3: Lu
<br />< UJ F-
<br />j: ix - f,
<br />F- >
<br />cn UJ Lu
<br />cc Er cr
<br />0 F- z
<br />u_ 0 0 U)
<br />z z z Lu
<br />rr < (n z
<br />u- -1 < _j
<br />ul CL m
<br />z:
<br />-i U) 0 0 Q
<br />YZ Z ILL U)
<br />P <
<br />cz
<br />0
<br />cz
<br />9
<br />4
<br /><
<br />Im
<br />W
<br />U)
<br />cq
<br />w
<br />0
<br />0
<br />z
<br />wi
<br />U)
<br />w
<br />w
<br />w
<br />w
<br />m
<br />z
<br />CL
<br />U)
<br />w
<br />z
<br />0
<br />R
<br />lz
<br />u
<br />U)
<br />III
<br />C3
<br />cn
<br />z
<br />0
<br />wlzM<j<j<1<
<br />c
<br />c
<br />JAN 2(92
<br />C 0 M M U N FTV
<br />LINKS @ CALUSA SPRINGS
<br />PLAN # 6120
<br />RELEASED: 1/27/22
<br />SHEET
<br />CS*2
<br />
|