My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37610-37622 Georgia Ter
Zephyrhills
>
Building Department
>
Building Plans
>
37610-37622 Georgia Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 8:04:12 PM
Creation date
2/27/2025 11:24:08 AM
Metadata
Fields
Template:
Building Plans
Street #
37610-37622
Location
Georgia Ter
Contractor
Lennar Homes
Building Plans - Permit #
12445-12448
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r-, <br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br />Fire Chief <br />Keith Williams <br />19 October 2011 <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br />This Officer has reviewed the submitted plans for a four (4) unit villa, new construction, <br />at 37610 to 37622 Georgina Terrace, in the Eiland Park Townhome development. <br />Following the review, a conditional approval to proceed is given. Payment for permit <br />acknowledges acceptance and compliance of the conditions noted herein. The following <br />items shall be considered: <br />1. Assurance of fire safe practices and in place in accordance to NFPA 1. <br />2. Unit 1398 does not include a smoke alarm in the master bedroom of that unit. <br />One must be included per code. <br />3. All circuit breakers controlling the circuits servicing the smoke alarm and <br />carbon monoxide detectors shall be equipped with a breaker lock to keep the <br />breaker from being turned off (NFPA 101, 4.6- AHJ requirement). <br />4. Ensure that electrical meters are addressed with respective address <br />designations. <br />5. Plans show UL listed fire wall separation constructed out of gypsum board. <br />No exposed wood or penetrations are allowed in the UL listed fire wall. Any <br />extension of truss assembly beyond masonry wall must be wrapped in rated <br />drywall. Inspections will be required. Wall must be placarded/labeled as <br />firewall at intervals of 15 feet spacing. <br />6. Fire wall separation shall extend through the soffit area to extreme outside of <br />structure. <br />Inspections Required: <br />1. Firewall 1 st layer screw inspection, 2nd layer screw inspection, final firewall. <br />2. Final building inspection. <br />Review and approval of the submitted plans does not relieve the contractor from the <br />responsibility of correcting any deficiencies noted during inspections. <br />Respectfull submitted on 19 October 2011 by, <br />Keith A. Williams, EFO, CFO, CMO, MIFireE <br />Fire Chief <br />Fire Safety Inspector <br />
The URL can be used to link to this page
Your browser does not support the video tag.