Laserfiche WebLink
Ui <br />i <br />i <br />i <br />i <br />i z <br />MINIMUM °J <br />HEADROOM <br />OR (2) <br />SLOPED PLANE <br />ADJOINING <br />TREAD NOSING <br />FROM FLOOR Q <br />SURFACE OF <br />LANDING i <br />FOR 51: 1 INCH = 25.4 mm, I FOOT = 3048 mm. <br />1`11NIMUM �4E:.ADRCO f <br />w <br />n <br />FOR SI: I INCH = 25.4 mm. <br />CONVENTIONAL STAIRU XT4 <br />EACH FLIGHT <br />REGULATED ON ITS OUR•. <br />GREATEST <br />DIFFERENCE BETWEEN <br />N GREATEST AND SMALLEST <br />Lu <br />TREAD DEPTH WITHIN A <br />FLIGHT OF STAIRS IS <br />LIMITED TO 3/8'. <br />DIFFERENCE BETWEEN HIGHEST AND <br />Sjl <br />LOWEST RISERS WITHIN A FLIGHT OF <br />STAIRS IS LIMITED TO 3/5'. <br />FOR 51: 1 INCH; = 25.4 mm. <br />STAIR TOLERANCES <br />14 RISERS a 11/2' EACH <br />PLUS I RISER is 13/4' <br />14 TREADS e 9 3/4' EACH <br />TOTAL HEIGHT = V-4 3/4' 2nd F.F. <br />_(3) 2x12 SYK SPACED <br />EVENLY W/ CONTR UCTION <br />ADHESIVE PL200 4 2-Vod <br />TOE NAILS AT EACH END <br />t42'WALF WALL W/ Ixb <br />WOOD CAP (SEE STAIR <br />PAGE FOR HANDRAIL <br />INFO.) <br />5-8 I/4' <br />9'-4 1/4' <br />STAIR DETAIL - 1530 -SIESTA KEY <br />SCALE: 1/4' = I'-0' <br />REFER TO SHEET 'STAIR' FOR W-OR 1ATION NOT SHOWN <br />4'-0' <br />/)P1=NI1J4 'A,_II I/1" <br />OVERHEAD <br />CABINETS <br />N <br />I II <br />N I II <br />I II <br />:_---ass-71 II <br />II II <br />� II II <br />11 11 <br />KITCHEN II II <br />KITCHEN PASS-THRU - SIESTA KEY <br />SCALE : 1/4' = 1'-0' <br />9 <br />Q <br />3' 0' 10140' <br />CONIC. PAD <br />I 2x4 WALL <br />I <br />COVERED PATIO <br />STOR <br />e <br />� <br />s <br />c1t� -0' 3'-i0" 5'-4' M. 0. <br />H 5-0x6-8 SGD <br />0 r <br />OOI P.W. <br />�? <br />— — <br />p 1 SINK <br />W/ DISP _ <br />I KITCHEN <br />z8 <br />I <br />I <br />u i <br />o REF. <br />_ <br />L---- _____ ____ c0 <br />a <br />U <br />4'-0' <br />Y-8' <br />4'-4' <br />1/2 WALL a 39 1/2' W/COUNTER <br />I <br />le <br />ABOVE: e 42' AFF. <br />IV WIDTH COUNTER ABOVE. <br />DINING ROOM <br />I — <br />4'-3' 6'-4 1/2" 3' 11 5/8' <br />DRAIN PAN, <br />DRAIN TO OUT 4' ARCH, <br />SIDE OF UNIT. SPRING 6'-8' <br />(SEE: 61.0 FOR Ep, TO 1'-4' <br />-LAYOUT) - — — — — <br />/2 WALL — — — — <br />�, <br />UNDER T.B. <br />1/2 BATH X <br />I <br />I <br />STARS <br />a <br />� <br />TILE: CffT. <br />O <br />C�' <br />���_ - IC�. I I l <br />M <br />I I I T.P.PRESSURE <br />---- <br />2'-1 1/2' 5' 0' 4' ARCH, <br />RELIEF <br />SPRING 6'-8' <br />LANDINIG UP TO 1'-4' <br />� <br />A <br />KY <br />1B <br />� <br />5'-9 I/4" <br />5-0 3/4" <br />HALF <br />I WALL I <br />I I <br />cn <br />to <br />C <br />I FAMILY ROOM I <br />c\v <br />I I <br />m <br />cv <br />I I <br />a <br />U <br />FOYER LLL <br />(2) 25 SH <br />%k EGRESS CID <br />d <br />C" <br />ENTRY <br />I 25 SH <br />_ <br />EGRESS <br />N <br />4'-3" 3'-0' T-V <br />1 st FLOOR PLAN - 1530 - SIESTA KEY <br />SCALE : 1/4' = 1'-0" <br />W-6" <br />(2) 25 SH <br />HD. HST. 6 -10' A.F.F. <br />ow <br />BEDROOM 2 <br />W-9' <br />`r <br />I <br />STUDY <br />Iz w <br />fa <br />o- LLL <br />DRYER VENT <br />(SEE NOTES) m a <br />HANSEN Its <br />2'-9 1/2' BOX I'-11" 3'-11 1/2' <br />7, <br />m <br />I <br />A/C <br />CHASE <br />I <br />� <br />m <br />DRYER ASHE <br />LIN <br />lZ X <br />T.B. IQ r zl <br />V5ATH <br />Q <br />48' BASECPT. <br />41E <br />�? <br />r VANITY 7 <br />O <br />>o <br />X w W.G. L <br />C <br />e <br />T T.P. M,C. <br />I; <br />I <br />LANDING p <br />m <br />3' I®' 3'-2 I/2' 3'-11 1/2' <br />A/R <br />LANDING I I Q X <br />I I <br />N <br />= <br />I I <br />' <br />8' BASE <br />o VANITY <br />V M.C. 2-6x6-8 <br />p <br />�u W.G. <br />M <br />I <br />� m TIL <br />m <br />Lu M. BATH <br />e <br />>� <br />10'-6 1/2" <br />I ' <br />N <br />I <br />A/C <br />CHASE <br />I <br />i <br />\, <br />co <br />MASTER SUITE <br />I <br />�I <br />al � , <br />I <br />I x <br />I 0 <br />�P <br />2' 1/2' 1111 1/2' <br />� <br />I <br />I <br />I I <br />I <br />I I <br />I <br />I <br />24/5 SH <br />HD. HGT. <br />�^ <br />6'-10' A.F.F. <br />I <br />25 SH <br />HD. HGT. 6'-10' AFF. <br />* EGRESS <br />I <br />2'-II" 3'-0' 2'-8' <br />2nd FLOOR PLAN - 1530 - SIESTA KEY <br />SCALE : 1/4' = 1'-0' <br />WASHER I <br />TUB �, , J <br />I � <br />` 0A LAV. 1/2" <br />I <br />I <br />KIT. <br />TUB ✓ 1/2' <br />l^ �, } ,� <br />�LAV• / <br />LAV <br />We 1/2" <br />H.W.H. 1/2' �y <br />4WC <br />TO-' <br />WATER <br />SERVICE <br />DOMESTIC WATER SUPPLY <br />SCALE: V.S. <br />PLUMBING LEGEND <br />= VENT LINE <br />= SANITARY WASTE LINE <br />-------- --_------= COLA WATER SUPPLY <br />w — Hw— = HOT WATER SUPPLY <br />NOTE: LICENSED PLUMBER TO VERIFY <br />AND HAS THE AUTHORITY TO <br />CHANGE AS NEEDED. <br />VTR i j 1 VTR <br />2" I. <br />TUB, ► ` i WAS <br />2 <br />2" �11/2" <br />� I <br />I <br />Tq' <br />T B i 1 1/2' 2" WC LAV i <br />I 1 1/2" <br />2" LAV I I <br />WC <br />BUILDING <br />WALL <br />TO <br />SEWER <br />SYSTEM <br />SANITARY WASTE RISER DIAGRAM <br />SCALE: N.T.S. <br />FLOOR PLAN NOTES <br />I. WALL DIMENSIONS ARE FROM OUTSIDE FACE OF BLOCK WALL <br />TO INSIDE FACE OF INTERIOR WALL. <br />2. DETERMINE THE LOCATION OF PARTITIONS NOT <br />DIMENSIONED BY THEIR RELATION TO COLUMN FACE OR <br />CENTER WINDOW JAMB OR OTHER SIMILAR FIXED ITEM. <br />1. EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT COMPLIES <br />WITH EGRESS CODES, IF THERE IS NO ACCESS TO <br />EXTERIOR THROUGH A DOOR THE WINDOW MUST HAVE A <br />MAXIMUM SILL HEIGHT OF 44' ABOVE FINISH FLOOR LINE <br />OF THAT PARTICULAR ROOM <br />2. ALL INTERIOR ANGLED WALLS ARE AT 45• U. N. 0. <br />3, ISSUANCE OF PLANS FROM THIS DES6NERS OFFICE SHALL <br />NOT RELIEVE THE BUILDER OF RESPONSIBILITY TO REVIEW <br />AND VERIFY ALL NOTES, DIMENSIONS, AND ADHERENCE TO <br />APPLICABLE BUILDNG CODES PRIOR TO COMMENCEMENT <br />OF ANY CONSTRUCTION. <br />ANY DISCREPANCY OF ERROR IN NOTES, DIMENSIONS, OR <br />ADHERENCE TO APPLICABLE BUILDING CODES SHALL BE <br />BROUGHT TO THE ATTENTION OF THE DESMR5 OFFICE <br />FOR CORRECTION BEFORE COMMENCEMENT OF ANY <br />CONSTRUCTION. <br />ANY REVISIONS OR CHANGES, NOT RELATED TO THE <br />CORRECTION OF ERRORS THAT ARE MADE AFTER THE <br />FINAL PLANS HAVE BEEN COMPLETED SHALL BE SUBJECT <br />TO ADDITIONAL FEES. <br />IF ANY MODIFICATIONS ARE MADE TO THESE PLANS BY <br />ANY OTHER PARTY OTHER THAN THE DES6NER6 OFFICE, <br />THE DESIGNER SHALL NOT BE HELD RESPONSIBLE. <br />4. EACH DWELLING MIT 4 GARAGE UNIT TO BE EQUIPTED W/ <br />PORTABLE FIRE EXTW%UI514ER IN ACCORDANCE W/ NFPAIO <br />5. DRYER VENT NOTE: <br />INSTALL BOOSTER FAN IN THE ATTIC TO ACCOMMODATE <br />THE EXCESS LENGTH OF THE DRYER VENT TO COMPLY <br />WITH SECTION M15013 FRC. LOCATE SO AS TO BE <br />ACCESSIBLE, <br />E)IMEN51ON CONVENTION <br />OVERALL 4 EXTERIOR OPENIWs DIMENSION <br />FROM OUTSIDE OF BLOCK <br />OUTSIDE FACE OF 6' <br />NOMINAL BLOCK <br />31/2' FRAME WALL UN.O. <br />AREA TABULATION <br />UNIT SIESTA KEY <br />Ist FLOOR LIVING 154 OF, <br />2nd FLOOR LIVING III OF. <br />TOTAL LIVING 1531 OF. <br />ENTRY 45 OF. <br />COVERED PATIO 69 SF. <br />STORAGE 18 OF. <br />TOTAL 6Q. FT. 1663 OF. <br />DAN SCO <br />ENGINEERING, LLC <br />P.O. BOX 3400 <br />Apollo Beach, Florida 33572 <br />p. 813.645.0166 <br />f. 813.645.9698 <br />www.danscoengineering.com <br />i <br />N - <br />Z Lu G <br />O�-.o <br />� = M <br />5 M O <br />z <br />oo�o <br />LLI >wN <br />QaQ�r <br />Z <br />< <br />W <br />z J <br />o� <br />_jIn <br />mi <br />In <br />Ln <br />w <br />U <br />I <br />0 <br />U <br />>z <br />0 Z <br />' <br />� <br />1 <br />0 <br />I <br />Z <br />Cv <br />I <br />J <br />� <br />Lu <br />— - <br />TO THE BEST OF THE ENGINEER'S <br />j <br />KNOWLEDGE AND BELIEF, THE STRUCTURAL <br />PLANS AND SPECIFICATIONS COMPLY WITH <br />2007 FLORIDA RESIDENTIAL BUILDING CODE, <br />(INCLUDING 2009 SUPPLEMENT) SECTION <br />R301 FOR 120 MPH, 3 SEC. GUST, <br />EXPOSURE <br />"C" ENCLOSED (INTERNAL PRESSURE <br />COEFFICIENT =±0.18) WIND ZONE <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS <br />AFTER THE DATE IT IS SIGNED AND SEALED. <br />SIGNED AND SEALED FOR THE STRUCTURAL <br />OF THIS DRAWING ONLY. <br />PORTION <br />2011 LENNAR CORP.-THIS PLAN MAY NOT BE <br />REPRODUCED IN ANY MANNER WITHOUT WRITTEN <br />CONSENT FROM LENNAR CORPORATION. <br />2011-THESE DRAWINGS AND DESIGNS ARE THE JOINT <br />PROPERTY OF DANSCO ENGINEERING, LLC AND THE <br />CLIENT ON THIS PROJECT. ANY REPRODUCTION OR <br />UNAUTHORIZED USE IS PROHIBITED. <br />REVISION: <br />DATE DESCRIPTION <br />09-29-09�1.00 2007 FBC UPDTATES <br />01-13-11 2.00 ADDED UNIT <br />1529 ST_JQHN ___ <br />07 12 11 2.01 HANGER CONN. AT <br />_- FLOOR TRUSSES_—______ <br />VERSION NO. 2.01 / 07.12.1 1 <br />CA 25948 <br />SAMUEL A. GREENBERG, <br />I P.E. #34245 <br />THUY H. HUYNH, <br />'wP.E. #60122 <br />IRWIN J. BENSON, <br />P.E. #49758 <br />_ zmmmmmem,a <br />C E Ns, <br />S' <br />vex S,/'••..., ••��,,�� <br />• •�mLL <br />%ET TITLE: <br />INDIVIDUAL UNIT <br />1530 - SIESTA KEY <br />SHEET INFORMATION: <br />JOB NO.: 310623 <br />I <br />DATE ISSUED: 07.19.11 <br />DRAWN BY: DZ <br />REVIEWED BY: TH <br />I B <br />iL —"I <br />�-7 <br />• <br />• <br />-44 <br />