Laserfiche WebLink
GENERAL STRUCTURAL NOTES: <br />1. ALL WORK SHALL CONFORM TO THE 2023 8th EDITION OF THE FLORIDA (INTERNATIONAL) <br />RESIDENTIAL CODE AND APPLICABLE COUNTY CODE AMENDMENTS. STANDARDS LISTED IN <br />STRUCTURAL NOTE SECTIONS REFER TO THE VERSION AND EFFECTIVE DATE IDENTIFIED IN THE <br />REFERENCED STANDARDS CHAPTER IN THE GOVERNING BUILDING CODE NOTED ABOVE. <br />2. THE STRUCTURAL NOTES ARE INTENDED TO AUGMENT THE DRAWINGS- SHOULD CONFLICTS <br />EXIST BETWEEN THE DRAWINGS AND THE STRUCTURAL NOTES, THE STRICTEST PROVISION <br />SHALL GOVERN. <br />3. THE STRUCTURAL DRAWINGS FORM AN INTEGRAL PART OF CONTRACT DOCUMENTS, WHICH <br />INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND CIVILISITE DRAWINGS. <br />COORDINATE THE STRUCTURAL DRAWINGS NTH THE REQUIREMENTS SHOWN IN THE OTHER <br />COMPONENTS OF THE CONTRACT DOCUMENTS. <br />4. TYPICAL DETAILS AND OTHER SECTIONS/DETAILS APPLY TO CONDITIONS THAT ARE SIMILAR TO <br />THE CONDITIONS DESCRIBED IN THE SECTIONS/DETAILS, EVEN IF THEY ARE NOT SPECIFICALLY <br />REFERENCED ON THE PLANS. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS SEQUENCES AND <br />PROCEDURES OF CONSTRUCTION, INCLUDING BUT NOT LIMITED TO TEMPORARY SHORING AND <br />BRACING. <br />6. DO NOT SCALE STRUCTURAL DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, <br />CONTACT THE ENGINEER. <br />7. CONSTRUCTION SHALL COMPLY FULLY WITH THE APPLICABLE PROVISIONS OF OSHA AND THE <br />LOCAL GOVERNING CODES, CURRENT EDITION, AND ALL REQUIREMENTS SPECIFIED IN THE <br />CODES SHALL BE ADHERED TO AS IF THEY WERE CALLED FOR OR SHOWN ON THE DRAWINGS. <br />THIS SHALL NOT BE CONSTRUED TO MEAN THAT REQUIREMENTS SET FORTH ON THE DRAWING <br />MAY BE MODIFIED BECAUSE THEY ARE MORE STRINGENT THAN THE CODE REQUIREMENTS OR <br />BECAUSE THEY ARE NOT SPECIFICALLY REQUIRED BY CODE. <br />8. THE ENGINEER'S SEAL APPLIES ONLY TO THE STRUCTURAL COMPONENTS ON THIS DOCUMENT. <br />ALL DIMENSIONS ARE TO BE VERIFIED WITH THE ARCHITECTURAL DRAWINGS. ANY DEVIATIONS <br />OR DISCREPANCIES ON THESE PLANS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF <br />THE ENGINEER OF RECORD. BACK CHARGES WILL NOT BE ACCEPTED, REGARDLESS OF FAULT, <br />WITHOUT PRIOR NOTIFICATION BY BUILDER WITHIN 48-HOURS AND INVESTIGATION BY <br />FIELDSTONE. <br />9. THE TERMS'CONCRETE SCREW AND'MASONRY SCREW SHALL BE USED INTERCHANGEABLY <br />WITHIN THESE DRAWINGS. CONCRETF/MASONRY SCREWS AS GENERICALLY SPECIFIED WITHIN <br />THESE DRAWINGS SHALL REFER TO ONE OF THE FOLLOWING ACCEPTED MANUFACTURER <br />PRODUCTS: SIMPSON STRONG TIE TITEN TURBO, GENUINE TAPCON, OR HILTI KWIK-CON 11. <br />10. CONTENT LINKED WITHIN OR CODES THAT MAY BE SHOWN WITH THE DRAWING SET ARE FOR <br />INFORMATIONAL PURPOSES ONLY AND THE PROFESSIONAL SEAL ON THIS DRAWING DOES NOT <br />APPLY TO CONTENT CONTAINED WITHIN ANY OR CODES. <br />I I.POST INSTALLED EPDXY ANCHORAGE GENERICALLY NOTED WITHIN THESE DRAWINGS SHALL BE <br />EITHER SIMPSON STRONG TIE SET-3G, OR HILTI HIT-HY-150 <br />DESIGN CRITERIA: <br />1. BUILDING RISK CATEGORY <br />2. VERTICAL LOADING: <br />ROOF TOP CHORD LIVE LOAD =20 PSF (REDUCIBLE) <br />ROOF TOP CHORD DEAD LOAD =7 PSF <br />ROOF TOP CHORD DEAD LOAD ITLE) -15 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/ STORAGE) =20 PSF <br />ROOF BOTTOM CHORD LIVE LOAD (w/o STORAGE) _-10 PSF <br />ROOF BOTTOM CHORD DEAD LOAD -10 PSF <br />FLOOR LIVE LOAD =40 PSF <br />FLOOR LIVE LOAD (SLEEPING ROOMS) =30 PSF <br />FLOOR DEAD LOAD -_15 PSF <br />DECK/BALCONY LIVE LOAD -_40 PSF <br />NOTE TO TRUSS & WOIST MANUFACTURERS - ROOF & FLOOR SYSTEM DELEGATED DESIGN <br />SHALL CONFORM TO THE FOLLOWING DESIGN STANDARDS: <br />LOCATION <br />I <br />TOTAL LOAD <br />I <br />LIVE LOAD <br />MAX TOTAL <br />DEFLECTION <br />ROOF TRUSSES <br />L/240 <br />L/240 <br />I.. <br />FLOOR JOISTSITRUSS <br />L/360 <br />L/4RO <br />1/2" <br />NOTES: <br />1. MAXIMUM TOTAL LOAD DIFFERENTIAL DEFLECTION BETWEEN ADJACENT PARALLEL <br />MEMBERS SHALL BE 5/8" <br />2. ANY MEMBER SUPPORTING BRICK/MASONRY SHALL BE LIMITED TO A TOTAL LOAD <br />DEFLECTION OF L/600 <br />3. FIELDSTONE AE CANNOT BE HELD RESPONSIBLE FOR ANY STRUCTURAL ISSUES RELATED <br />TO ANY BUILDING COMPONENT IF COMPONENT SHOP DRAWINGS ARE NOT SUBMITTED TO <br />FAE FOR REVIEW PRIOR TO FABRICATION, DELIVERY, OR INSTALLATION <br />3. LATERAL LOADING <br />WIND CRITERIA: TORNADO WIND SPEED N/A <br />BASIC WIND SPEED =140 MPH <br />EXPOSURE CATEGORY -C <br />INTERNAL PRESSURE COEFFICIENT 0.18 (ENCLOSED) <br />SEISMIC CRITERIA <br />SITE CLASS <br />SEISMIC DESIGN CATEGORY <br />4. EARTH PRESSURE LOADING: <br />ALLOWABLE SOIL BEARING CAPACITY <br />TOTAL LOADS (INCLUDING WIND & SEISMIC) =2000 PSF <br />LATERAL EARTH EQUIVALENT FLUID PRESSURE <br />WALLS UNBRACED AT TOP -=40 PCF <br />WALL BRACED AT TOP -55 PCF <br />5. GUARDRAIL/HANDRAIL LOADING: <br />ALL GUARDRAIL/HANDRAILS SHALL MEET 2DO LBS (MINIMUM) CONCENTRATED FORCE APPLIED <br />IN ANY DIRECTION. IN -FILL COMPONENTS OF GUARDRAIL SHALL MEET 50 PSF. THESE LOADS <br />ARE TO BE EVALUATED INDEPENDENTLY AND ARE NOT TO ACT CONCURRENTLY WITH ANY <br />OTHER LIVE LOAD. DEFLECTION OF GUARDRAIL SHALL MEET THE CRITERIA SET FORTH BY THE <br />INTERNATIONAL CODE COUNCIL EVALUATION SERVICES (ICC-ES) AC 273 - "ACCEPTANCE <br />CRITERIA FOR HANDRAILS AND GUARDS-" <br />CONCRETE NOTES: <br />1 . STRUCTURAL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE PER ACI 332 "RESIDENTIAL <br />CODE REQUIREMENTS FOR STRUCTURAL CONCRETE�. <br />2. CONCRETE PRODUCTION AND PLACEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 332 <br />"RESIDENTIAL CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" EXCEPT AS MODIFIED BY <br />STRUCTURAL REQUIREMENTS NOTED ON THE DRAWINGS. <br />3� CEMENT SHALL CONFORM TO ASTM CI 50 "SPECIFICATION FOR PORTLAND CEMENT." CONCRETE <br />SHALL BE NORMAL WEIGHT, UNLESS INDICATED OTHERWISE. <br />4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C33 "SPECIFICATION FOR CONCRETE <br />AGGREGATES." <br />5. REINFORCING SHALL CONFORM TO ASTM A-615 GRADE 60. <br />6. REINFORCEMENT SHALL BE FABRICATED AND ERECTED ACCORDING TO THE ACI STANDARDS: <br />"DETAILS AND DETAILING OF CONCRETE REINFORCEMENT', ACI 315 - AND "MANUAL OF <br />ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES", ACI 315R. <br />7. REINFORCING STEEL AND WELDED WIRE FABRIC SHALL BE PLACED WITH MINIMUM CONCRETE <br />COVER AND TOLERANCES AS FOLLOWS: <br />SLAB4DN-GRADE: WITHIN UPPER 2/3 OF SLAB AND 314" MINIMUM COVER AT INTERIOR <br />CONDITIONS; 1-1/2"MINIMUM COVER AT EXTERIOR CONDITIONS <br />CONCRETE FWNDATIC" AGAINST EARTH: 3" <br />FORMED CONCRETE: 1-1/2" (#5 REBAR OR SMALLER) 2" (#6 REBAR OR LARGER) <br />TOLERANCE: +/- 3/8" <br />8. REINFORCING STEEL SHALL NOT BE CUT, BENT OR STRAIGHTENED IN THE FIELD UNLESS <br />APPROVED BY THE STRUCTURAL ENGINEER OR AS INDICATED ON THE DRAWINGS- <br />9. WELDING OF REINFORCING STEEL IS PROHIBITED UNLESS SPECIFICALLY DETAILED. WELDING <br />WHERE DETAILED SHALL CONFORM TO AWS D1.4 SPECIFICATION. <br />CONCRETE NOTES (CONTINUED): <br />10. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH AS FOLLOWS: <br />FOUNDATIONS & FOUNDATION WALLS: 25DO PSI <br />SLAB -ON -GRADE & CONCRETE BEAMS: 25DD PSI <br />11. CONTRACTOR SHALL TIE REINFORCING STEEL SECURELY IN PLACE PRIOR TO PLACING <br />CONCRETE AND PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THEIR POSITION WITHIN <br />SPECIFIED TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES. INSERTING DOWELS INTO <br />WET CONCRETE IS NOT PERMITTED. ANCHOR RODS AND STEEL INSERTS SHALL BE SET BY <br />TEMPLATE TO WITHIN A 1/8" TOLERANCE IN ANY DIRECTION WITH MINIMUM EMBEDMENTAND <br />EXACT PROJECTION INDICATED ON THE DRAWINGS, PRIOR TO PLACING CONCRETE. <br />12. HOOKED BARS SHALL BE STANDARD 90 DEGREE HOOKS PER ACI UNLESS NOTED OTHERWISE ON <br />THE DRAWINGS. MINIMUM LAP SPLICE SHALL BE CLASS B PER ACI 318. LOCATION OF LAP <br />SPLICES SHALL BE AS INDICATED ON CONSTRUCTION DOCUMENTS. <br />13. DOWELS INTO FOUNDATION SHALL MATCH SIZE AND SPACING OF VERTICAL REINFORCEMENT AT <br />ALL COLUMNS, PIERS AND WALLS, UNLESS OTHERWISE NOTED. <br />14. CONTRACTOR SHALL OBTAIN APPROVAL PRIOR TO PLACING OPENINGS OR SLEEVES NOT SHOWN <br />ON THE DRAWINGS, THROUGH ANY STRUCTURAL MEMBER. <br />15. ONE OF THE FOLLOWING CONCRETE SLAB ON GRADE CRACK CONTROL METHODS SHALL BE <br />USED (CONTRACTOR PREFERENCE): <br />CONTROL JOINTS: SHALL BE FORMED, SAWED, OR TOOLED TO A I" MINIMUM DEPTH WITHIN <br />24 HOURS OF CONCRETE PLACEMENT. MAXIMUM JOINT SPACING FOR UNREINFORCED SLAB <br />IS AS FOLLOWS: <br />3-1/2"SLAB: 8 FEET D.C. EACH DIRECTION <br />4" SLAB: 10 FEET O.C_ EACH DIRECTION <br />WELDED WIRE FABRIC (W.W.F.) 6X6.Wl.4XWI.4. WELDED WIRE FABRIC SHALL BE FURNISHED IN <br />FLAT SHEETS (ROLLS NOT PERMITTED) AND SHALL CONFORM TO ASTM A-1 064 AND HAVE A <br />MINIMUM SIDE AND END LAP OF 8 INCHES. <br />MICRO- OR MACRO- SYNTHETIC FIBER REINFORCEMENT <br />FIBER LENGTHS SHALL BE 1/2"TO 2-1/4" IN LENGTH. DOSAGE AMOUNT SHALL BE FROM 3/4 TO <br />3.0 POUNDS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. SYNTHETIC <br />FIBERS SHALL COMPLY WITH ASTM CI 116. THE MANUFACTURER/SUPPLIER SHALL PROVIDE <br />CERTIFICATION OF COMPLIANCE WITH ASTM CI 116 WHEN REQUESTED BY THE BUILDING <br />OFFICIAL. <br />16.CONTROL JOINTS SHALL BE FURNISHED WITH A FULL-LENGTH KEYWAY CENTERED ON MEMBERS. <br />WHERE THE SIZE OF KEY IS NOT SHOWN ON THE DRAWINGS, THE KEY SHALL BE 25% OF THE <br />CROSS-SECTION DIMENSION OF THE MEMBER AND MINIMUM 1-1 /2 INCHES INTO THE FIRST POUR <br />OF CONCRETE. <br />17. PROVIDE POCKETS OR RECESSES IN CONCRETE WORK FOR COLUMNS AND BEAMS AS REQUIRED <br />EVEN IF NOT SHOWN ON THE DRAWINGS. PROVIDE CONCRETE FILL AFTER BEAM ERECTION- <br />18. CURING OF CONCRETE SURFACES SHALL CONFORM TO ACI 308.1 "STANDARD SPECIFICATION <br />FOR CONCRETE CURING" AND ACI 308R "GUIDE TO CURING CONCRETE". <br />FOUNDATION NOTES: <br />I . CONTRACTOR SHALL VERIFY ALL CONDITIONS, INCLUDING UNDERGROUND UTILITIES AND FIELD <br />MEASUREMENTS AT JOB SITE AND REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE. <br />2. TOP OF SPREAD FOOTING ELEVATIONS NOTED ON PLAN ARE MINIMUM ELEVATIONS. IN ALL CASES <br />FOOTINGS ARE TO BEAR ON UNDISTURBED NATURAL SOILS OR ENGINEERED FILL HAVING A <br />MINIMUM NET ALLOWABLE BEARING CAPACITY OF 2000 PSF. <br />3. SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING. <br />FOUNDATIONS POURED AGAINST THE EARTH REQUIRED THE FOLLOWING PRECAUTIONS: SLOPE <br />SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING <br />BEFORE AND DURING CONCRETE PLACEMENT. PROVIDE POLYETHYLENE VAPOR RETARDER <br />COMPLYING WITH GOVERNING BUILDING CODE LISTED ON THIS SHEET AGAINST SOILS WHERE <br />CONCRETE IS TO BE PLACED; LAP ALL EDGES 6 INCH (MINIMUM) AND SEAL WITH ADHESIVE. <br />4. WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO STEEPER THAN ONE VERTICAL TO <br />TWO HORIZONTAL U.N.O. <br />5. FOOTINGS SHALL BE CENTERED UNDER COLUMNS AND WALLS UNLESS SPECIFICALLY DETAILED <br />OTHERWISE ON THE DRAWINGS <br />6. NO FOOTINGS OR SLABS SHALL BE PLACED ON OR AGAINST SUB -GRADE CONTAINING FREE <br />WATER, FROST OR ICE. SHOULD WATER OR FROST, HOWEVER SLIGHT, ENTER A FOOTING <br />EXCAVATION AFTER SUB -GRADE APPROVAL, THE SUB -GRADE SHALL BE RE INSPECTED BY THE <br />GEOTECHNICAL ENGINEER/ TESTING LABORATORY AFTER REMOVAL OF Wj�­TER OR FROST. <br />7. CONTRACTOR SHALL FURNISH ALL REQUIRED DE -WATERING EQUIPMENT TO MAINTAIN A DRY <br />EXCAVATION UNTIL BACKFILL IS COMPLETE. <br />8. A GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF WORK PERFORMED SHALL INSPECT <br />THE CONDITION AND ASSURE THE ADEQUACY OF ALL SITE PREPARATION, SUBGRADES, FILLS, <br />BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS AND WALLS. HE SHALL <br />SUBMIT REPORT TO THE ARCHITECT/ENGINEER DESCRIBING HIS INVESTIGATIONS OF ANY <br />NON -CONFORMING WORK, <br />BACKFILLING: <br />1 - DO NOT PLACE BACKFILL AGAINST FOUNDATION WALLS - DESIGNED AS SUPPORTED AT TOP AND <br />BOTTOM - UNTIL BASEMENT LEVEL AND FIRST FLOOR SYSTEM ARE IN PLACE. SHORE AND/OR <br />BRACE WALLS AS REQUIRED IF BACKFILLING OPERATIONS ARE TO BE CARRIED OUT PRIOR TO <br />PLACEMENT OF FLOOR SYSTEM. <br />2. WHERE BACKFILL IS TO BE PLACED ON BOTH SIDES OF FOUNDATION WALLS, PROVIDE A <br />BALANCED RACKFILL AGAINST FOUNDATION WALLS TO ELIMINATE LATERAL LOAD EFFECTS, OR <br />PROVIDE NECESSARY TEMPORARY LATERAL SUPPORT TO THE TOP OF THE WALL UNTIL <br />PERMANENT SUPPORT IS INSTALLED. <br />3. BACKFILL MATERIAL SHALL CONSIST OF CLEAN, WELL GRADE GRANULAR SOILS, FREE OF <br />ORGANIC MATERIAL AND BE COMPACTED TO 95% OF MAXIMUM DENSITY, AS DETERMINED BY <br />THE MODIFIED PROCTOR METHOD (ASTM D1557), IN LIFTS NOT EXCEEDING 8 INCHES. <br />MASONRY NOTES: <br />I . CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE NTH ACI 530,"BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES"AND SHALL BE CONSTRUCTED IN ACCORDANCE <br />WITH ACI 530.1, "SPECIFICATIONS FOR MASONRY STRUCTURES.� <br />2. CONCRETE MASONRY SHALL CONFORM TO ASTM C90 AND HAVE A MINIMUM COMPRESSIVE <br />STRENGTH Fm = 1,500 PSI U.O.N. MASONRY SHALL HAVE A TEXTURE SUITABLE FOR STUCCO <br />APPLICATIONS WHERE ARCHITECTURAL DRAWINGS INDICATE STUCCO APPLICATION. <br />3. CONCRETE MASONRY UNITS SHALL BE LAID IN RUNNING BOND. <br />4. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 WITH MINIMUM COMPRESSIVE <br />STRENGTH OF 2,000 PSI. MORTAR BELOW GRADE SHALL BE TYPE M. ELSEWHERE MORTAR MAY <br />BE EITHER TYPE M OR S UNLESS SPECIFICALLY INDICATED OTHERWISE. USE EITHER PORTLAND <br />CEMENTILIME OR MASONRY CEMENT FOR MORTAR. <br />5. GROUT SHALL CONFORM TO ASTM C476 VVITH MINIMUM 28-DAY COMPRESSIVE STRENGTH OF <br />2 500 PSI. <br />6. S�EEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A61 5, GRADE 60. <br />7. VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, <br />FREE OF MORTAR DROPPINGS. <br />8. VERTICAL CMU WALL REINFORCING SHALL BE AS NOTED ON THE DRAWINGS. DOWELS TO <br />CONCRETE FOUNDATION TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING UNLESS <br />NOTED OTHERWISE. REINFORCE CMU CORE AT CORNERS, EACH SIDE OF CONTROL JOINTS AND <br />EACH SIDE OF WALL OPENINGS NTH (1)45 CONTINUOUS VERTICAL REINFORCING BARS.. <br />9. HORIZONTAL BOND BEAM AND VERTICAL REINFORCING SHALL BE CONTINUOUS U.O.N. LAP <br />SPLICE REINFORCING PER THE SCHEDULE OR USE MECHANICAL SPLICES ADEQUATE FOR 125% <br />OF SPECIFIED YIELD STRENGTH OF THE BAR. LAP VERTICAL REINFORCEMENT WITH M <br />DOWELS OF SAME SIZE AND SPACING THAT HAVE BEEN PREVIOUSLY INSTALLED IN T�W <br />FOUNDATIONS. DOWEL EMBEDMENT IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF <br />THE CONCRETE NOTES. <br />BARSIZE <br />LAPSPLICELENGTH <br />BENDDIAMETER <br />ACIHOOK <br />#4 <br />2V' <br />3" <br />IV, <br />#5 <br />25" <br />3-3/4" <br />19, <br />#6 <br />34" <br />4-1/2' <br />11... <br />MASONRY NOTES (CONTINUED): <br />10. REINFORCING BARS SHALL BE HELD IN POSITION BY WIRE TIES OR OTHER APPROVED MEANS TO <br />ENSURE DESIGN LOCATION AND LAP. PLACE BARS AND LAP PRIOR TO GROUTING. <br />11. GROUTING OF MASONRY WALLS SHALL CONFORM TO RECOMMENDED PROCEDURE FOR "LOW <br />LIFT GROUTING"OR "HIGH LIFT GROUTING"AS OUTLINED IN THE NCMA-TEK 3-2A - GROUTING <br />FOR CONCRETE MASONRY WALLS AND ACI 5301ASCE 5 SPECIFICATION FOR MASONRY <br />STRUCTURES. GROUT LIFTS SHALL NOT EXCEED 6 FEET WITHOUT MECHANICALLY <br />CONSOLIDATED (VIBRATED) GROUT POURS. <br />12- LIFTS OF GROUT SHALL BE KEYED 4 INCHES INTO THE PREVIOUS COURSE OF MASONRY BELOW. <br />13. MASONRY BELOW GRADE SHALL BE GROUTED SOLID. <br />14. CONTRACTOR SHALL BRACE MASONRY WALLS TO RESIST WIND LOADS UNTIL FLOORS AND <br />ROOFS ARE IN PLACE, AND THE MASONRY HAS REACHED 75% OF THE REQUIRED STRENGTH FM. <br />BRACING SHALL BE PROVIDED IN ACCORDANCE WITH OSHA - CONSTRUCTION SAFETY <br />STANDARDS FOR MASONRY WALL BRACING AND NCMA TEK 3-4B -BRACING CONCRETE <br />MASONRY WALLS DURING CONSTRUCTION." <br />WOOD FRAMING NOTES: <br />I . STRUCTURAL SAWN LUMBER, STRUCTURAL COMPOSITE LUMBER, AND CONNECTIONS HAVE <br />BEEN DESIGNED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION.- (NDS) <br />2. PLYWOOD HAS BEEN DESIGNED IN ACCORDANCE WITH"PANEL DESIGN SPECIFICATION."AND <br />SHALL CONFORM TO"VOLUNTARY PRODUCT STANDARD PSI CONSTRUCTION AND INDUSTRIAL <br />PLYWOOD." <br />3. ORIENTED STRAND BOARD (OSB) SHALL CONFORM TO -VOLUNTARY PRODUCT STANDARD PS2 <br />PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS". <br />4. ALL BEAMS AND HEADERS SHALL BE (2)-PLY U.N.O. <br />5. WOOD SILL PLATES AND WOOD WALLS SUPPORTED ON CONTINUOUS CONCRETE OR MASONRY <br />SHALL BE ANCHORED WITH 1/7DIAMETER CAST -IN -PLACE ANCHOR BOLTS WITH 71, EMBEDMENT, <br />4- (MINIMUM) AND 12- (MAXIMUM) FROM END OF SILL PLATE(S), LOCATED WITHIN THE MIDDLE <br />THIRD OF THE SILL PLATE, WITH NUT AND 3-x3-4.229- WASHERS AT THE ANCHOR SPACING <br />BELOW: <br />MAXIMUM ANCHOR BOLT SPACING= 2'-O"O.C. <br />REFER TO"PREAPPROVED FIELD REPAIR NOTES" SECTION FOR ALTERNATE ANCHORAGE <br />APPROVALS. FOR OTHER ANCHORS NOT LISTED, SUBMIT TO ENGINEER OR RECORD FOR <br />REVIEW. <br />6. ALL LUMBER IN CONTACT WITH EARTH, CONCRETE, OR MASONRY - AND WOOD BEAMS <br />POCKETING INTO CONCRETE OR MASONRY WALLS HAVING CLEARANCES LESS THAN 1/2" ON <br />TOP, SIDES, AND END(S) SHALL BE PRESSURE TREATED OR SEPARATED WITH AN IMPERVIOUS <br />MOISTURE BARRIER. <br />7. STRUCTURAL SAWN LUMBER SHALL BE SPRUCE -PINE -FIR NO.1 /NO.2 OR BETTER U.N.O. WITH <br />BASE DESIGN VALUES: <br />F�= 875 PSI F� = 425 PSI FT = 450 PSI Fc= 1150 PSI Fv= 135 PSI E= 1400 KSI <br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />8. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE (2X) TOP PLATES <br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS. END JOINTS IN <br />DOUBLE (2X) TOP PLATES SHALL BE OFFSET AT LEAST 24 INCHES AND SHALL BE NAILED WITH <br />NOT LESS THAN (8)-0_1 62"x2-1/2" FACE NAILS ON EACH SIDE THE JOINT. DOUBLE (2X) TOP PLATES <br />OF EXTERIOR WALLS AND INTERIOR LOAD BEARING WALLS SHOWN ON DRAWINGS SHALL BE <br />SOUTHERN YELLOW PINE NO.2 OR BETTER WITH BASE DESIGN VALUES: <br />F�=110OPSI F,=565PSI FT=675PSI F�=145OPSI Fv=175PSI E=1400KSI <br />WITH THE MOISTURE CONTENT OF THE WOOD IN SERVICE WILL NOT EXCEED 19%. <br />9. STRUCTURAL COMPOSITE LUMBER SHALL CONFORM TO ASTM D W6 WITH THE FOLLOWING <br />ALLOWABLE DESIGN STRESSES <br />MKAXXLAM LVL PARALLAM PSL TIMBERSTRAND LS <br />E = 20DO KSI E 1800 KSI E 1300 KSI <br />F, = 2600 PSI F� 2400 PSI F, 1700 PSI <br />I-) - 'BOOZER BEAM 2.1 E' ARE AN ACCEPTED ALTERNATE TO PSL COLUMNS SPECIFIED <br />ON PLANS PROVIDED THE'BOOZER BEAM 2.1 E'IS OF EQUAL OR GREATER SECTION <br />DIMENSION TO THE PSL COLUMN AND OF EQUAL OR LESSER HEIGHT <br />10. FLOOR SHEATHING SHALL BE 23/32 INCH, APA RATED SHEATHING, 48/24 MIN., EXPOSURE 1. <br />INSTALL WITH THE LONG DIMENSION OR STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS <br />AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPANS. PANEL EDGES SHALL BE <br />TONGUE -AND -GROOVE. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO SUPPORTING <br />MEMBERS. ADHESIVE SHALL MEET APA SPECIFICATION AFG.01, APPLIED IN ACCORDANCE WITH <br />THE MANUFACTURER'S RECOMMENDATIONS. PROVIDE 0.131 "x2-1/2" COMMON NAILS AT 6 INCH <br />O.0 ALONG SUPPORTED PANEL EDGES AND 12 INCH O.G AT INTERMEDIATE SUPPORTS. <br />1 I.FOR INTERIOR WALL HEADERS PROVIDE (l)-2X JACK STUD AND (l)-2)(KING STUD U.N.O. ON <br />DRAWINGS. <br />12. FOR EXTERIOR WALL HEADERS PROVIDE (1)-2x JACK STUD AND (l)-2x KING STUD, MINIMUM, <br />REFER TO CHART BELOW U.N.0 ON DRAWINGS: <br />WINDSPEE OF <br />C <br />140 EXP. C <br />WALL HEIGHT <br />8FT <br />9FT <br />JOF <br />10FT <br />STUD <br />SIZE <br />HEADERSPAN <br />IT <br />4 <br />1J/IK <br />IJ/IK <br />1J/IK <br />6 <br />IJ/lK <br />1J/1K <br />1J/2K <br />8 <br />IJ/IK <br />IJ/2K <br />J/"K <br />10 <br />J/2K <br />1 J/4K <br />2X4 <br />12 <br />_LJ/2K <br />'j, <br />/2K <br />_L <br />1J/3K <br />I JAK <br />14 <br />J/2K <br />IJ/4K <br />ENG <br />16 <br />1 J/3K <br />I J/4K <br />ENG <br />18 <br />__ <br />1 J/3K <br />FE NG <br />FENG <br />WIN PEED OF <br />< = 140 EXP. C <br />WALL HEIGHT <br />8FT <br />9FT <br />10FT <br />STUD <br />SIZE <br />HEADERSPAN <br />(Fr) <br />4 <br />IJ/1K <br />IJ/1K <br />1X/l K <br />6 <br />1J/1K <br />IJ/1K <br />1J/1K <br />8 <br />IJ/IK <br />IJ/IK <br />1J/IK <br />10 <br />1J/1K <br />1JAK <br />1J/IK <br />2,6 <br />12 <br />IJ/1K <br />1J/1K <br />1J/IK <br />14 <br />11/1 <br />IJ�IK <br />IJ�IRK <br />1: <br />IJ/�K <br />jj"k <br />ljI <br />1 <br />1 <br />13.WALLSSHOWN ON THE FRAMING PLANSARE LOAD BEARING WALLS; WALLS NOTSHOWN ON <br />STRUCTURAL FRAMING PLANS ARE INTERIOR NON -LOADING BEARING PARTITION WALLS. <br />14. LOAD BEARING WALLS SHALL BE CONSTRUCTED WITH 2X STUDS AT 16"O.C. MAXIMUM U.N.O. <br />NON -LOAD BEARING PARTITION WALLS SHALL BE CONSTRUCTED WITH 2XOR METAL STUDS (18 <br />GA. MIN.) @ 24- D.C. MAXIMUM. <br />15. STUD COLUMNS UNDER LOAD BEARING POINTS OF GIRDERS/BEAMS SHALL MATCH THE <br />GIRDERIBEAM PLY COUNT WITHIN 1/2" TOLERANCE (2-PLY STUD COLUMN MINIMUM). SOLID <br />BLOCK ALL GIRDERIBEAMS THRU FLOOR SYSTEMS AND TO THE FOUNDATION. <br />16. WHEN NOT SHOWN ON DRAWINGS OR DETAILS, THE NAILING SCHEDULE FOR WOOD FRAMING <br />ELEMENTS SHALL COMPLY WITH THE IRC TABLE R602.3(l). <br />17. FLOOR SYSTEMS ARE DESIGNED BY THE TRUSS ANDIOR WOOD I- JOIST MANUFACTURERS <br />DELEGATED ENGINEER AND BE IN CONFORMANCE WITH THE LOADS & DEFLECTIONS IDENTIFIED <br />IN THE DESIGN CRITERIA NOTES SECTION. INSTALL PER MANUFACTURER'S RECOMMENDATIONS, <br />NOTES, AND DETAILS. FLOOR FRAMING CONCEPT LAYOUTS SHOWN WITHIN THE DRAWINGS ARE <br />FOR ILLUSTRATIVE PURPOSES ONLY TO DEPICT FLOOR SYSTEM -TO -WALL CONNECTIONS. <br />CHANGES TO THE CONCEPTUAL FLOOR LAYOUT SHOWN IS NOT PERMITTED WITHOUT A LET -TER <br />AND REVIEW FROM THE ENGINEER OF RECORD. PREFABRICATED WOOD I -JOIST SHALL <br />CONFORM TO ASTM D 6W6. <br />JURISDICTION SPECIFIC NOTES: <br />I FOR PARTIALLY ENCLOSED AREAS, INCLUDING BUT NOT LIMITED TO LANAIS, PORCHES, AND <br />BALCONIES A 1/2' (MINIMUM) EXTERIOR GRADE SOFFIT BOARD WITH A CEMENITTIOUS <br />KNOCKDOWN FINISH IS ACCEPTABLE PROVIDED THAT IT IS PAINTED MEETING THE <br />REQUIREMENTS OF ASTM C932 TO GIVE THE CEILING WATER RESISTANCE. THE SOFFIT BOARD <br />PRODUCT SHALL BE ATTACHED PER MANUFACTURER SPECIFICATIONS TO BE IN COMPLIANCE <br />WITH R703.1. <br />2, THE SOFFIT DESIGN PRESSURE IS AS NOTED IN THESE DOCUMENTS- WITH KAYCAN VINYL SOFFIT <br />INSTALLED IN ACCORDANCE WITH MANUFACTURER'S REQUIRMENTS AND ICC-ES EVALUATION <br />REPORT ESR-1495 THE SOFFIT WILL COMPLY WITH R703.1. <br />PRE-ENGINEERED ROOF TRUSS NOTES: <br />I . ROOF TRUSS SHOWN ON STRUCTURAL DRAWINGS IN CONCEPTUAL ONLY TO ILLUSTRATE <br />TRUSS -TO WALL CONNECTIONS AND DOES NOT SERVE AS A ROOF TRUSS DESIGN. ROOF <br />TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN CONFORMANCE FOR THE INDICATED <br />LOADS WITH ANSI/TPI I "NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD <br />TRUSS CONSTRUCTION." FINAL PRE-ENGINEERED ROOF TRUSS FRAMING LAYOUT AND DESIGNS <br />TO BE BY ROOF MANUFACTURERS DELEGATED ENGINEER. <br />2. ROOF TRUSSES SHALL BE DESIGNED FOR THE SUPERIMPOSED LOADS IDENTIFIED IN THE <br />DESIGN CRITERIA NOTES SECTION. <br />3. THIS PLAN IS DEVELOPED FROM THE REVIEW OF MASTER TRUSS FILES_ ANY LOT THAT DEVIATES <br />FROM THE MASTER TRUSS FILE ON RECORD,OR FOR PLANS FIELDSTONE AE IS NOT <br />CONTRACTED TO PERFORM TRUSS REVIEW ON, THE CONTRACTOR IS RESPONSIBLE TO ASSURE <br />THE DIRECT COMPLIANCE OF TRUSS MANUFACTURER LAYOUT TO THESE DRAWINGS & VERIFY <br />ALL TRUSS CONNECTORS ARE SUFFICIENT TO WITHSTAND THE UPUFT/LATERAL LOADS IMPOSED <br />4- TRUSS MANUFACTURER SHALL PROVIDE HANGERS AND CONNECTIONS ADEQUATE FOR LOADS <br />AT ALL TRUSS -TO -TRUSS, TRUSS-TO-BEAMI, AND BEAM -TO -TRUSS CONNECTIONS- <br />5. REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS SHAPE, OVERHANG, DIMENSIONS, SLOPES, <br />SPANS, DRAINAGE, BEARING WALL HEIGHTS, ETC. <br />6. THE POSITIONS, WEIGHTS, AND METHODS OF ATTACHMENTS OF ALL MECHANICAL UNITS, <br />ELECTRICAL FIXTURES, PLUMBING, FIRE SPRINKLERS, ETC SHALL BE INCLUDED IN THE DESIGN <br />OF THE TRUSSES BY THE TRUSS MANUFACTURER. SEE ARCHITECTURAL DRAWINGS FOR ATTIC <br />ACCESS SIZE AND LOCATIONS. <br />7. SUPERIMPOSED LOADS FROM SECONDARY FRAMING (I.E. SOFFITS, PARAPETS, VALLEY FRAMING, <br />UPPER TRUSSES, ETC) SMALL BE INCLUDED IN THE DESIGN OF SUPPORTING TRUSSES. <br />8. CONTRACTOR TO PROVIDE TRUSS BRACING PER BCSI-B3 IN ADDITION TO PERMANENT BRACING <br />SHOWN ON THE TRUSS DESIGN PROVIDED BY THE DELEGATED TRUSS ENGINEER. <br />PRE -APPROVED FIELD REPAIR NOTES: <br />I MISPLACED DOWEL REPAIR: THIS NOTE DESCRIBES ALTERNATES TO MITIGATE THE CASTING OF <br />REBAR VERTICAL REINFORCEMENT AT AN INCORRECT LOCATION. <br />IF THE WALL HAS NOT BEEN BUILT: DRILL AND EPDXY #5 REBAR (36" LG.) INTO THE THICKENED <br />EDGE OF SLAB AT THE CORRECT LOCATION. AS WALL IN CONSTRUCTED, LAP REBAR IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12" LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMIBOND BEAM. COMPLETE <br />GROUTING OF WALL. <br />IF THE WALL HAS ALREADY BEEN BUILT: PRIOR TO GROUT PLACEMENT, OPEN THE WALL AT THE <br />CORRECT LOCATION APPROXIMATELY 16" (H) x 4" (" AT FLOOR LEVEL. DRILL AND EPDXY #5 <br />REBAR (32- LG.) INTO THE THICKENED EDGE OF SLAB. LAP VERTICAL REINFORCEMENT IN <br />ACCORDANCE WITH MASONRY NOTES LAP SCHEDULE, PLACING A HOOKED BAR WITH 12- LAP AT <br />THE TOP OF WALL WITH THE CONTINUOUS REBAR IN THE TIE BEAMIBOND BEAM. COMPLETE <br />GROUTING OF WALL. <br />2. MISSING/MISPLACED ANCHOR BOLT: ALTERNATE SILL PLATE ANCHORAGE SOLUTIONS <br />INTO CONCRETE: <br />A 1/2"x6" TITEN H D WITH 1-3/4" M I N I M LIM EDGE DISTANCE AND 6" MINIMUM END DISTANCE IS A <br />DI RECT 1: 1 REPLAC EMENT FOR A 1/2" DIAMETE R ANCHOR BOLT WITH 7" EMBE DMENT I NTO <br />CONCRETE. <br />A 1/2" THREADED ROD SET-3G EPDXY 7" EMBEDMENT WITH 1-3/4" MINI MUM EDGE DISTANCE AND <br />7-1/2" MINIMUM END DISTANCE IS A DIRECT 1:1 REPLACEMENT FOR A 1/2" DIAMETER ANCHOR <br />BOLT WITH 7" EMBEDMENT INTO CONCRETE. <br />INTO GROUT FILLED MASONRY (GPCMU): <br />A 1/2"x6"TITEN HD WITH 1-3/4" MINIMUM EDGE DISTANCE AND 8" MINIMUM END DISTANCE AT 4�4* <br />O.C. REPLACES A 1/2- DIAMETER ANCHOR BOLT WITH 7- EMBEDMENT AT 9-9'O.C.; LIKEWISE A <br />1/2"x6- TITEN HD WITH 1-3/4- MINIMUM EDGE DISTANCE AND 8- MINIMUM END DISTANCE AT 7-8 <br />O.C. REPLACES A 1/2" DIAMETER ANCHOR BOLT WITH 7" EMBEDMENT AT 4!-0" O.C_ <br />3. SIMPSON MASA SILL ANCHORS MAY BE USED AS AN ALTERNATE TO THE ANCHOR BOLTS AND <br />SPACING NOTED HERE -IN ACCORDING TO THE FOLLOWING TABLE: <br />BASIC WIND <br />SPEED (MPH) <br />MAXIMUM <br />SPACING <br />� 140 <br />6'.01' <br />mi,. <br />140 <br />1.-,, <br />150 <br />NOTES: <br />1. MASA SPACING BASED ON NO MORE THAN ONE IN THREE INSTALLED WITH ONE LEG <br />INSTALLED VERTICALLY ATTACHED TO STUD <br />MISSING/MISPLACED TRUSS STRAP ANCHOR: REFER TO"MISSED TRUSS STRAP REPAIR"DETAJL <br />WITHIN DRAWINGS. <br />FOR MISLOCATED TRUSS ANCHORS WHICH ARE GREATER THAN 1/8" BUT LESS THAN 1-11/2" FROM <br />THE FACE OF THE TRUSS, A SHIM SHALL BE PROVIDED AND NAIL LENGTH INCREASED TO <br />PENETRATE THROUGH BOTH PLYS OF MATERIAL (I.E. 3- LG. NAILS). WHEN GAP IS GREATER THAN <br />1-1 /2", INSTALL NEW ANCHORS. <br />MASONRY WALL OVERHANGING SLAB <br />BLOCK OVERHANG REPAIR <br />� 5/8" NO REPAIR REOD <br />5/8" < OVERHANG < 1-1/2" GROUT SOLID BOTTOM 3 COURSES OF AFFECTED WALL LENGTH <br />>1-1/2" CONTACT ENGINEER OF RECORD FOR REPAIR <br />NOTCHED TOP PLATES & STUDS REQUIRING REPAIR <br />AT STUDS: STRUCTURAL REPAIR IS REQUIRED AT STUDS WHEN A STUD IS NOTCHED TO A DEPTH <br />GREATER THAN 25% OF THE WIDTH IN BEARING WALLS, OR 40% IN NON -LOAD BEARING WALLS; <br />OR WHEN A HOLE IS DRILLED/BORED TO A DIAMETER EXCEEDING 40% OF THE STUD WIDTH IN <br />BEARING WALLS, OR 6W. OF THE STUD WIDTH IN NON -BEARING WALLS. IF THE MAXIMUM <br />HOLE/NOTCH SPECIFICATIONS ARE EXCEEDED THEN A STUD SHOE MUST BE INSTALLED. STUD <br />SHOE REPAIRS ARE AS FOLLOWS: FOR 2X STUD USE HSS2-SDS1.5 WITH (I 2)-1/4"XI-1/2"SDS <br />SCREWS. FOR MULTI -PLY 2X STUDS USE HSS2-"#--SDS3 WITH (12)-1/4-X3- SOS SCREWS, WHERE <br />"#"CORRESPONDS TO THE NUMBER OF STUDS IN THE MULTI -PLY. <br />AT TOP PLATES: A HOLE, CUT, OR NOTCH THAT IS GREATER THAN 50% OF THE PLATE WIDTH IS <br />REMOVED FOR PIPING (EXCEPT WHEN THE SIDE OF THE WALL WITH THE NOTCH OR CUT IS <br />COVERED BY WOOD STRUCTURAL PANEL SHEATHING), OR THE PLATES ARE CUT THROUGH. THE <br />REQUIRED REPAIR IS A GALVANIZED 1fGAUGE METAL TIE THAT IS AT LEAST 1-1/2"WIDE AND <br />MUST BE FASTENED WITH (8)-16D NAILS ON EACH SIDE OF THE OPENING. <br />0 <br />ORD Fieldstone <br />C.O.A.# ARCHITECURE: <br />AA26002802 <br />C.O.E.# ENGINEERING: No. 86 <br />29349 <br />El IBRAHEM ELAYEB, PE <br />P.E.# 91476 <br />OF <br />N BENJAMIN NIESE, PE <br />00 <br />P.E.# 86025 <br />.......... <br />06/20/2024 INAL. <br />DATE 111111" <br />r <br />2 <br />_2 <br />Z <br />_2 t E - 5 <br />Z <br />8 h. - <br />.6 <br />& <br />Michigan <br />3400 Auburn Rd <br />Suite 200 <br />Auburn Hills, MI 48326 <br />+1 248.622.4035 <br />Florida <br />12906 Tampa Oaks Blvd. <br />Suite 150 <br />Tampa, FL 33637 <br />+1 813.466.3310 <br />www.fieldstoneae.com <br />C) <br />z <br />z <br />Z <br />V) <br />C) <br />U <br />> <br />C) <br />Eli <br />E­ <br />01 <br />SWAT <br />IDRAWN BY: I FAE] <br />VERSION: 5.0 <br />SHEET NAME <br />COVER SHEET <br />SHEET # <br />SO.1-140 <br />