Laserfiche WebLink
IN <br />HEEL --------------------- <br />12 <br />5� <br />12 <br />\�5 <br />F4 <br />T.O.M. <br />HDR HGT. — <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />F.FL. J <br />FRONT ELEVATION - Al <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. <br />HDR HGT. <br />—----- -------------------- -------------------- <br />1'-0" <br />------------------------- --------------------------------------- V <br />6" FASCIA <br />(TYP) <br />3'-0" <br />10 TEXTURED o <br />CEMENTICIOUS °Q 0o <br />FINISH ON C.M.U. Zo <br />(TYP.) <br />------------------------------------- F.FL. <br />LEFT ELEVATION - Al <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />SRO W N <br />`NN <br />f• • <br />'•� <br />S <br />:• <br />J <br />•. <br />''\ <br />LO `�.•$ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Wco <br />3fr� Q <br />.{ <br />of� <br />O M 8 <br />C-,N J <br />9) <br />N C)CD (p J L, <br />7r-a�v a- <br />tr. <br />Lu <br />U <br />C J LL <br />W"13 u- L` d 2w' <br />o <br />rn I <br />NN c0 E O <br />7 0 <br />m <br />�2nrn m aF <br />Z <br />LL <br />Q Q F <br />o a r <br />t..°' I <br />N M Z X D) O <br />OU U ai <br />Z <br />x W <br />❑ ❑ El <br />V M � <br />Z N o <br />Z � N <br />Z � � <br />J — <br />U) <br />r <br />M <br />N <br />z <br />� o <br />� <br />a--J <br />N <br />OLU <br />S <br />m <br />�Nco <br />U <br />U O N <br />O <br />Q OD Y <br />N mco <br />C:, <br />co2 <br />J <br />o <br />m¢'yN <br />w <br />Z <br />� <br />C <br />QE <br />E O <br />o0 <br />? <br />'aR <br />z® <br />❑a <br />(6 <br />�O <br />Up <br />Z <br />H C <br />O ro <br />N <br />d0 <br /><o <br />�Z <br />a <br />�w <br />L <br />cn C <br /><o <br />ox <br />ym <br />m0 <br />a <br />Z <br />Z <br />Q) <br />v <br /><, <br />}Z <br />: <br />Za <br />> <br />> <br />pp <br />Z <br />2U <br />W <br />Q� <br />U <br />wLL <br />ep <br />'oz <br />3 <br />00 <br />�w <br />¢ a <br />a <br />�V <br />C <br />C O <br />i <br />> <br />rn <br />f0 <br />c� <br />L <br />� <br />> <br />0 <br />O <br />Y <br />o <br />O <br />�1 <br />L.L <br />o <br />pp <br />T <br />��• <br />V <br />r <br />2 N <br />04 Ll) <br />LO <br />T_ <br />2 O) <br />rn v <br />r <br />E <br />O <br />c <br />0-) <br />CO <br />iii <br />o <br />Z <br />cc <br />Z <br />E O <br />(n <br />c`o <br />a:0 <br />E <br />� <br />Q p <br />c <br />J <br />JOB <br />NO: <br />21-5012 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />