39982 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39982 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:08:00 AM
Creation date
2/27/2025 11:16:40 AM
Metadata
Fields
Template:
Building Plans
Street #
39982
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
2151
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />III 21t <br />#14 copper to lights & outlets <br />150 AMP/ It 12 copper to 20 amp ckts <br />200 AMP 10 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect �IT <br />POWER CO. FEED 1.• I <br />INTERSYSTEM 4 Bare Cu Ground •V� /�I <br />BONDING #4 GROUNDING WIRE V <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17. National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PE�W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />t'��` <br />HALF -SWITCHED DUPLEX OUTLET <br />f-Op <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />qP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />T 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />6� <br />(1) PHONE LINE, (1) DATA PORT <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />II +, VLVIVII I LV r,LVL-t I L-L <br />WP H.B. FOR MICROWAVE RANGE <br />GFI DISC. HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />DI III rIGD <br />ELECTRICAL PLAN — ELEV—Al <br />SCALE: %4"=1'-0" <br />N <br />0 <br />N <br />Ln <br />0 <br />v <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a <br />V E <br />o a8 <br />� � <br />N" <br />O N a <br />J <br />JLL <br />r <br />i' G <br />O C <br />N <br />o CW" <br />J . <br />u �` w <br />M <br />N <br />cnt-- r-La <br />CN b <br />m v <br />J w a <br />LL CL <br />a <br />JLL LL <br />CL ui <br />Z <br />-a <br />o <br />W <br />� m� <br />oco <br />t0 N <br />° <br />a O J <br />W <br />(n c rn <br />m J <br />¢ < <br />rsLL00 <br />O <br />M Z <br />J a <br />O <br />aZ <br />N <br />OU <br />a= <br />UJ rn <br />- Z <br />s W <br />❑❑❑ <br />V M �2 <br />z � o7T <br />z <br />z o � <br />Q <br />J13— <br />r <br />cNi <br />N <br />z D <br />� o <br />11 <br />Vi <br />W N <br />— <br />O <br />(/ <br />w a <br />C < <br />VI <br />ytn <br />� <br />c <br />W N <br />C) O y <br />c to <br />Q N <br />0 <br />Q <br />s eo <br />o <br />Z <br />Mz <br />J <br />o <br />�a <br />Z <br />Z <br />LL <br />E <br />z o <br />> <br /><R <br />E o <br />�F <br />z <br />Z® <br />d <br />oa¢ <br />to <br />g`°1 <br />oZ <br />OE <br /><Z <br />C14ZL <br />o <br />¢ o <br />m <br />� � <br />:n <br />�a <br />0 U <br />O <br />o� <br />Z <br />Z <br />J <br />m'aw <br />a ° <br />Ez <br />n <br />o� <br />Z <br />o <br />a <br />W <br />wLL <br />�z <br />x 3 <br />J <br />O <br />J� <br />aQ <br />-o <br />o <br />v <br />zla <br />'a= <br />° 3 <br />> Ln <br />rn <br />0 <br />W <br />O <br />d) <br />� <br />N <br />Q <br />' <br />O <br />O <br />U <br />O <br />m <br />c <br />T <br />`o o <br />r <br />c <br />CV Lo <br />00 <br />LO <br />T <br />m <br />T <br />C) <br />cn <br />E <br />w <br />= <br />co <br />o <br />Z <br />Z <br />E O <br />a <br />) _j <br />¢ o <br />JOB <br />NO: <br />21-5012 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />