W W <br />118"CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU -MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT Al - <br />SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOW BUCK <br />\ <br />2) SEALART JOINT <br />\ <br />5) SEALANT FR Om <br />INSIDE EDGE OF <br />WINDOW FRAME <br />N INDOWSLICK <br />W <br />ACROSS WINDOW BUCK <br />X�DIEXTEND TO <br />INDOW FRAME <br />MASONRY— <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUICK ALL THF"�,VAY <br />AROUND, INCLUDINGSILL <br />SCS 06 05 CMU INSTALLATION 6 POINTBUCK AND <br />E <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEVI <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4'CEMENT PLASTER <br />12 MlL (min) DRYLOK EXTREME <br />APPROVED FlASHING 'APE <br />-V` SEALANT SOCKET WIT H <br />TOOLED APPROVED SEALANT <br />WEATHER <br />r— RESISITIVE <br />A. BARRIER <br />WEA <br />HER <br />VE BARRIER & <br />�ARIIL Y SECURE <br />WOOD FRAME CWON5TR. <br />EXTERIOR SELF -ADHERED FLllI <br />SHEATHING BY LAPPING DOWN <br />OVER RIM J(DIS T AND UP <br />I BY 6 IN- <br />IlVEATHER <br />RESISITIVE <br />BARRIER <br />SEALTOI�:15 OFJOP <br />UN DEIR, [')ECK, �N(3 <br />(SEE DETAIL. INIT'07) <br />ED FLASHING <br />1. Cut. fold up & ternpoorarily secure Weather <br />1 r=_! <br />HEAD FLASHING IE-UN INSTRUXTIONS: <br />resistive barrier above header to allmw for <br />flashing Installation <br />2, _Self= -adhered flashing plus head ffash�ng under <br />weather resistive ba mer <br />3. Fofd weather resistive barrier back over head <br />2 <br />flashing and seal with tape <br />SELF -ADHERED !FLASHING Scale: NTS <br />FLANGED WINDOW 1WP01 <br />RLASHING INST ALLATION AFTER 10-fEATHER REQ13imATIVE BARRIER <br />DO NO- <br />BOTTO <br />F <br />L <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instruictions <br />Refer to the number marked as 0#) in each detail that corresponds to the <br />numbered! iterns in the list of instructions, below- <br />1 . Install self -adhered flashing in order as shown by numbers <br />2- Instal! flashing and weather resistive barrier to form water shedding <br />laps <br />1 Self -adhered flashing can be subStitUted for building paper <br />4� Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to SUbstrate using a square piece, of flashing material (6" x 6" <br />Minimum) <br />& Fold as shown by arrows <br />7. Angle of comer may vary, adjust folding of the flashing acccrdingly to <br />fit tight to cornef <br />Mechanically fasten as necessary <br />A <br />SM0,110, <br />2x FRAMEWALL <br />TILE FINISH <br />1/2" DUROCIII <br />8" CMU <br />4" OR 8" CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED — <br />VINYL SHOWER PAN <br />-A <br />kSHING <br />2 <br />E <br />AM <br />WP07 <br />1'4'PER PLAN <br />1"-0" PER PLAN <br />A <br />4 <br />2" <br />WEATHER RE-13TIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHF-ATHING <br />34%1" BEAD OF CO?I*TR� <br />ADHESIVE TO BE APPLIED UNDER <br />T HIRESHOLD OF DOOR AND R.-I URN <br />UP JAMB 6" USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECT"nA,.1;EE DETAIL. <br />----------- <br />SELF-ADHERED IFLASH,ING J <br />C2) <br />SEAL TO%1' OF JOISTS <br />UNDER DECKING <br />(SEE RETAIL WP07) <br />SELF-ADHER <br />< <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />z z <br />15 <br />CL <br />Cr cr_ <br />LU <br />UJ <br />U) <br />0 <br />W W <br />W <br />U) 3: <br />0 <br />A <br />WINDOW UNIT FLASHING REQUIREMENTS <br />DOOR RlI OPENING <br />—SLOPE <br />R703.1 General, Exterior walls shall. provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />-3 in: 12.0 in <br />_114". 1" BEAD OF CONST R, (0 6 cm : 30. 5 c m) include flashing as described in Section R703.4- <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />REI IJRN UP JAMB 6"'. USE L10IJ1131 R7031 -1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />NAiL BRAND OR EUUAL VVLA � HEIR A EXTERIOR <br />PROOF CAD -- I CEIVIT. FIN, within wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />draining to the exte water that penetrates the exterior cladding- <br />SELF-AiDHaRIED FLASHING B'UILDING PAPER <br />L WIRE 'LATH R703.2 Water -resistive barrier. One layer of No, 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />SUBFI OOR! approved water resistive barrier snail be applied over studs or sheathing of all exterior walls No <br />15 asphaftfelt shall be applied horizontally <br />-ER <br />CONTINUOUS RACTIC <br />ROD & SEALANT <br />. <br />, <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt <br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and terrninated at penetrations and building <br />RIM <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703,1 <br />J <br />Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where appliedover wood -based <br />R703_7_3 <br />�2e­_ I A. A 1 rr__ sheathing. shall include a water -resistive vapor -permeable barrier with a performance at Ifeast equivalent to two layers of Grade D paper- The <br />J <br />2 <br />individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers, <br />SELF -ADHERED FLASHING <br />WPO12 CEMT.FINISH SILL/ POTSHELF/CHIMNEY SHOULDER WP03 Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-mmute Grade D paper and is separated from the stucco by an interv6ning, <br />substantiall-ff nonwater-absorbing layer or designed drainage space- <br />MECHA ICALILY FASTEN IF RUBBERIZED ASPHALT y <br />NEEDED IN CORNERS ADHESIVE <br />INSTALL SE1 F-ADHE-PED THRCIUP�H SELF -ADHERED ASPHALT ADHESIVE <br />R703.4 'Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied <br />ra <br />FLASHING, SEE LASHINI I SEILF-ADHERED FLASHING�_ <br />FLANGED VONDOW shing.e-fashion or in accordance with the manufacturees instructiors, Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />CSFE UF-TAIL WPGI� <br />used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />CORED entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered !,Membranes used as flashing shall comply with XAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />FOLONG =ORF <br />ADHH1F:0I FLAS -­G the building wall with a sealant complying with AAMA 80D or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />SEI " i __ art EA'SE PAPER TO EfPOSE <br />EXTEND A MINIPAW, W <br />1; yr contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERT� _N L FWAO ADHESIVE AS SHOWN6 <br />BOTT&L. OF flashing in exterior walls shall comply with AAMA 714- The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD <br />shall be installed at the following locations: <br />1 Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703-2 for subsequent drainage, Mechanically attached flexible flashings <br />shall compF r With AAMA 712- Flashing at exterior Window and door openings shall be installed in accordance with one or more of the <br />y <br />(1 2 following: <br />or for applications not addressed in the fenestration <br />1.1 The fenestration manufacturers installation and flashing I <br />manufacturers instructions, in accordance! with the flashing manufacturers instructions, Where flashing instructions or details are <br />4 ') <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings- Pan flashing shall be sealed or <br />> (6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />--I drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1,2 1 .2, In accordance with the flashing design or method of a registered design !,Professional. <br />1.3 1.3. In accordance with other approved methods, <br />SELF-ADHERIED FLASHING <br />INSIDE CORNER 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDIVIA35100 or �FMA/AAMA/WDMA 400, <br />WP05 WP06 2- 2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />3.3.Under and at the ends of masonry, wood or rnetall copings and sills. <br />Ground -I <br />4- 4-Continuously above all projecting wood trim. <br />5. 5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6- 6-At wall and roof intersections. <br />W <br />t <br />Resi <br />t <br />t �B <br />r <br />i <br />7� -17.At built-in autters. <br />ITCH <br />HERED FLA's1I <br />(2 � F <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />��D_IND BRE-41 WRB <br />sF� L.dt-rt�t <br />WRAP D P WR 8 ON T 0 <br />Tf-JE VERTICAL <br />S <br />,LJRFACE TO TOP OF <br />PLANGE ASANI AIR <br />BARRIER <br />1-1,Q'INCH FLANGE <br />THIS GAP IS A RESH T -I <br />NATURAL SHRIN�A-_--_ <br />DO NOT SEAL. <br />R3P SCREED PLA$T1 <br />SOFFITItICANTILEVER <br />LEGEIN' D <br />SELF ADHERED FLASHING (SAF) <br />DRAINAGE PLANE (OP.) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BRL:�AK WFAT'HER RESISTANT BARRIER <br />SELF FUR'f'!UN(,, LATH <br />PLASTER 4CCESSCRY — <br />OD DEN a -CI <br />'099% PLYWOt <br />`ZSTER STOP <br />\ITINUOUS BACKER ROD <br />EALANT <br />t,1ENTI"Tlc)US FINISH <br />r <br />Lath <br />Sheathing <br />Stucco <br />STRUCTURAL FRAIJINC'� <br />T <br />S R _LK�TURAL SHEATHING <br />PIP OF SAF <br />DRAINAGE PLANE %V <br />BOND BREAK WP5 <br />LATH <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Centent Plaster <br />in acrordinci- with <br />ASTMC-926 <br />Felt backed <br />V <br />metal <br />lathe in accordance <br />with ASTMC1063 <br />.,N <br />Building Paper <br />-7/16" O.S.B. <br />% <br />sheathing <br />Metal <br />Flashing <br />N <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />%: <br />a <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Cement Plaster <br />I.. accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />EEP SCREED DETAIL <br />W <br />SCALE: NOT TO SCALE <br />4 <br />4 <br />All <br />4 <br />40 <br />4 <br />40 <br />40 <br />Virtual Revi Assist, Inc. <br />Plans Review com leted and approved <br />for compliance with t e 2020 FBC 7th Edition <br />by Debra An Klahr PX2300 <br />Ite <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16"O,S.& <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per, <br />Manufact. Specs. <br />112" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />40 <br />40 <br />40 <br />