A/C <br />DISC <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATIONS A & B) <br />1 /4" = 1'-0„ <br />R <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN <br />Q <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�---- 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />Virtual Review Assist, Inc.V <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH- <br />0 <br />4 1/2" <br />DOORJAMB DUPLEX 19 <br />OUTLET M <br />TRIM--- <br />BASE--- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />DETECTOR <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTAC <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--� DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />-{14} CLG MNT LT FIXTURE <br />{- CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />0 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY <br />0 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />0 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYE <br />V CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />°U-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />.-- D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24� 24" VANITY LIGHTING <br />� 36 � 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />L� 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />03 CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />� ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />� A/C REGISTER <br />Q THERMOSTAT <br />l2 SECURITY PAD <br />LES <br />AL <br />BE <br />BY <br />BALLI <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />- <br />4 ,r _ <br />e <br />,y <br />I,-)E <br />c(y)� ti <br />5 <br />to <br />� D � � u rn <br />=a <br />1 O 2 o <br />0 <br />O Eo 9 Q <br />�Cq <br />•� <br />}4t <br />w <br />C <br />cQc'N <br />L O C M <br />r\ O �0 @ <br />w <br />LwF w _j Lq 0 <br />I- Q - Z d' <br />Q z <br />� Q <br />♦— <br />U <br />F- <br />aCyXJzW�LL LLoz2°0'Qa <br />oWa°W�zoWO°�00zzZ)�L) <br />Z <br />d CO W W z 2 Q <br />Q~wpg<-zwO��OpQ <br />W J <br />LL <br />oox � <br />o oQQ�¢Q <br />LLQ o LL <br />O <br />O <br />N <br />Z <br />OF- <br />U) Z) ti <br />z <br />cM O <br />Q U) (M Lo <br />0- (/) <br />LL <br />2 U) <br />z <br />< W Ln <br />F- of o- M <br />�0-2- <br />Z U F- <br />z 3: <br />WW <br />J0 <br />(fl <br />I <br />1, <br />I <br />I <br />I <br />I <br />r <br />O <br />O <br />d <br />O <br />O <br />O <br />N <br />O <br />O <br />N <br />O <br />` <br />, <br />N <br />O <br />C) <br />O <br />a <br />O <br />r <br />N <br />O <br />N <br />O <br />Z <br />O <br />W <br />N <br />Lo <br />W <br />> <br />o <br />0 <br />N <br />0 <br />M <br />0 <br />d' <br />0 <br />6 <br />'^ <br />ZI- <br />W <br />v, <br />Q z <br />w <br />O <br />W <br />coo <br />}� <br />O <br />U <br />U � <br />Lo <br />O <br />0wo <br />Z <br />a -a <br />Ln <br />Ln <br />C7 <br />mF-2 <br />N <br />Z = <br />°o0 <br />W <br /><F-D <br />. . <br />N <br />Q <br />O <br />ZWO <br />r <br />U <br />wx <br />zU_ <br />Z <br />az <br />QF� <br />� <br />OU <br />a. <br />_p <br />W <br />ZA6.11 <br />W <br />ti <br />� <br />Co <br />>A.-i <br />LAST PLOT DATE <br />• <br />May 2, 2022 <br />z <br />O <br />1 6T FLOOR <br />_..I <br />ELECTRICAL PLAN <br />