ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />i <br />----------------------------------------- I <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide ProtecUon: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination AJarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I - ELECTRICAL KEY I <br />KD-: <br />DUPLEX CONVENIENCE OUTLET <br />I ±, <br />P_P_ <br />DUPLEX OUTLET ABOVE COUNTER <br />K#W:.P. <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />nQ ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />7TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />t THERMOSTAT <br />0 ELECTRIC METER <br />PP7 ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />09 (1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 -/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />)pper to ilghts & outlets <br />)pper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />LANT <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. I <br />----------------------------------------------------------------------------------- <br />L--------------------------------- <br />L------------------------------------------ J <br />2nd FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />La <br />Z co <br />-0 <br />Z <br />L/) (D <br />Q) <br />C—/) <br />11M <br />4—J LLJ <br />U <br />0 Uj <br />I, E <br />(/) <br />un <br />0 <br />0 CO, <br />0 <br />0 <br />C14 <br />IJ_j <br />E <br />8 <br />(D Cl) <br />a M <br />C C', C', <br />1�0 :2 cl) <br />0 Ccq <br />0) <br />.20 <br />U_ co <br />1 CD <br />C) 0) <br />(D <br />Q) <br />:3 <br />0 .2 i::- <br />05 <br />g <br />< 0 <br />U.) 0 <br />'r CL <br />0) < <br />8 Do <br />�Rco <br />C" <br />CN LO <br />ce) <br />C 14 <br />(0 L0 <br />U, r­ <br />C,4 <br />C-4 <br />CS <br />0 0 <br />�E Z <br />M Z <br />0? C14 <br />U) r.- — <br />U- <br />r N 0 <br />LLI , 7� <br />(L CL <br />< LL <br />LLI U L� - -so <br />Z0 -0, 0 :3 <br />Z r1j <br />A 9 Z-) <br />M 04 <br />Z I Z <br />LL <br />W <br />(50 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />C) <br />Z N <br />0 o) <br />�-4 4-J C) <br />ILI) <br />C) <br />C:) <br />fy) <br />4-J <br />U) <br />U) ON <br />— <br />LL <br />rL fy) <br />6- 0. 00 <br />Z 3i E <br />Z <br />LU C:) <br />0 <br />ED LL 0 <br />LLJ Z W <br />F- <br />LU CO Z Z <br />U LU <br />1,- V) 0 <br />0 <br />z z L) <br />0 zofLw <br />Z >- < U X < <br />Act <br />Z Z Z <br />LU Z <br />wo L-9 <br />C"4 <br />S 0 <br />LLj 04 <br />C:) <br />0 Z <br />Uj = Z <br />(y) <br />LU <br />C:) <br />Lr) <br />1714 <br />117�4 <br />Ln <br />LU o <br />Lu F- 3: <br />Z <br />LU 0 0 <br />0 <br />< <br />< <br />U LFU- V1 <br />E 0 Z <br />-0 <br />Z <br />_j <br />Z :5 LZU 0� <br />- CY-- Z <br />0 :::) <br />Z <br />LU <br />0 0 <br />(DW ZO <br />< U <br />2: <br />0 LU <br />2 > 0 <br />LLJ 0 LL Z <br />C<' F- '0 8 <br />C'4 <br />T-11 <br />Z) < W In <br />CyZ LL Z <br />(n X Z < <br />0 <br />C:) <br />M <br />r F— <br />_j LL, <br /><,L <br />a <br />rt) C) <br />Z <br />. . <br />. . Lij <br />LU <br />> <br />Z <br />Z <br />0 <br />:5 W <br />SCALE AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: FFLORES <br />VERSION NO. <br />1122 <br />J013 NO: 16-6649 <br />SHEET NO. <br />6 <br />