My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6608 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6608 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:11:14 PM
Creation date
2/27/2025 11:26:45 AM
Metadata
Fields
Template:
Building Plans
Street #
6608
Location
Wagon Trail St
Contractor
Lennar Homes
Building Plans - Permit #
19503
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CORNER OF <br />HOME <br />GARAGE SIDE <br />J <br />Cam' <br />w <br />J <br />m <br />0 <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIfX;F I INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + O <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + . + + + + + + p <br />+ + + + + + + + + -I- + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ '-0" (TYP.) <br />60 <br />++ <br />+ + <br />60° <br />+ <br />+ <br />+ <br />+ <br />++ <br />++ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ + <br />+ + <br />++ <br />++ <br />+ <br />+ <br />+ + + + +++ + <br />+ <br />+ + + + + ++++++ <br />+ <br />+ + <br />+ + + + + + <br />+ + <br />+ + + + + + + + + <br />+ <br />+ <br />++++++ + + <br />+ <br />+ + + + + + + + + <br />+ + <br />++ <br />++ <br />++ <br />+ <br />Uj <br />— 15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />BRIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAYBE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER, <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCIOJoist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood anels or 2 x <br />P — <br />1-1 /8" or two 1 /2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1 /2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap <br />/ <br />FILL CELL STD. 90° HOOK BOND BEAM <br />CO <br />w <br />`t <br />CONT. #5 <br />STD. 90° <br />CONT. #5 <br />BAR <br />HOOK <br />BAR <br />,7 � <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. ) Small gap 2" min. <br />2" <br />max. � 4 max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />2x4/Plyght fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. SB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />----- - - Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* over squash=20 blocks and <br />Non -stacking walls <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate 1l16" <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK -LESS W/H <br />H C G <br />00 O <br />5'-0" a - <br />STUB OUT FOR 1'-0" 0 9 0 <br />LO <br />GAS METER O 0 <br />1 � O <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-V <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />I Ice 3" /1ndl nails nt 6" n r. <br />Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRIG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />11 <br />Web Stiffener Fastener Schedule <br />Joist B aring Location <br />Series I Depth I End Intermediate <br />BCI 5000s® <br />9-1/2" <br />1 2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />1 2-8d <br />5-8 <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />1 2-8d <br />2-Sd <br />2-8d <br />3-8d <br />14" <br />12-8d <br />5-8d <br />16" <br />i 2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />1 3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />U, <br />M <br />5/8"1 <br />THF <br />BOL <br />R TRUSS <br />"OP PLATE <br />LC <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF <br />SECOND RT16 <br />a <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d A 1/2" NAILS <br />UPLIFT = 1030# <br />TYPICAL RT16 INSTALLATION <br />higher than 15001b. <br />TYPICAL HTA 20-18 / HTA 20 <br />BLOCKING PANEL, INTERIOR INSTALLATION TYPICAL MTW INSTALLATION <br />Vertical load transfer =1900 plf max, along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoidfl PLUMBING LINE <br />vertical plumbing TOP (2) #5's x 4' 0" <br />3" max CENETERED @ PIPE PVC OR SCH40 SLEEVE <br />JOISTS OFFSET A/C CHASE 4" PVC PENETRATION <br />N.T.S. SLEEVE THRU STEM ° <br />WALL a . <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.— <br />an <br />C.0 t <br />6„ A 1Yz" ROUND HOLE MAY 6. 6" —DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1%" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Joist hanger <br />Backer block (12" wide min.) III 1 III — II 11-11 I � = I I —4 <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM <br />SEE PLAN FOR °. a .. <br />FOUNDATION INFO 4 <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1l4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />t-vl, unmoC 4 rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />BELOW <br />GRADE PIPE VERTICAL THRU FND. <br />G <br />PVC OR SCH40 SLEEVE <br />TOP (2) #5's x 4' 0" <br />CENETERED @PIPE <br />PENETRATION PLUMBING LINE <br />a 4 4 / <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d ° 4 4° ° Qo G <br />a <br />=1 El <br />° <br />I �L�° I�,Ijlll <br />SEE FND. PLN. <br />SIZE & REINF. <br />cD V <br />zM <br />0 <br />e o <br />z N <br />Q <br />El- <br />Cn (D <br />� W <br />C6 p <br />W <br />O <br />T <br />~ <br />o <br />i� V) k— <br />o 0 <br />ap cN <br />C)Ql <br />Cl) <br />W s <br />~ $ <br />MIN00 <br />mtoc) <br />O O N <br />C:,s <br />= <br />�I �IU <br />LL eo <br />Unoo <br />Q CM <br />u7 v <br />rn ¢ o <br />N c 9 D c <br />v <br />aCa m �: 1J <br />a <br />N <br />00 <br />o R <br />Cq <br />U) <br />Z <br />441110 ln, 2 ✓ <br />W"V' -C1 <br />Zb.`�cr <br />aaa� <br />�.. <br />UMz <br />O t°i <br />�. <br />To the best of the Engineer:'q,�nowlLdgeanforfi tion <br />belief, the structural plans anVipaepifcations coaqt <br />within these drawings comply with Ykiii.kOF j jm id <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />11 <br />0 <br />O <br />Z N <br />O W N <br />��o <br />k>1 M O <br />M <br />aU-) M`" <br />L_ 0 Ln <br />Q P J.- <br />Q e- , <br />QU a OC) <br />Z c0 <br />CD <br />WLU <br />Ct <br />MJ <br />oz <br />ce0 <br />wo <br />za <br />a� <br />fF <br />�z080 <br />Z OW W K <br />z <br />zz <br />��w <br />a ow, <br />O aV <br />W N <br />C1) <br />W <br />Z Z <br />;o <br />fz <br />Ln <br />0 <br />O <br />5 <br />ro <br />� <br />o <br />> <br />N <br />Iiz <br />o <br />U <br />U <br />a <br />Lu <br />W <br />oW <br />oZ <br />tV <br />A <br />'ate` <br />�/) <br />V <br />Z¢0< <br />W O J <br />(D z <br />Q <br />v <br />O g <br />z <br />(V <br />a <br />u_oto <br />Z <br />J <br />Ifs <br />LU <br />W z z l- <br />W _ <br />ri <br />w <br />la- U.0 <br />2 Qu <br />00 <br />ro <br />Q <br />Z <br />aWz <br />Ln <br />Z <br />Ln <br />g <br />Z <br />J <br />` z <br />o <br />06 <br />= <br />Lu <br />r7l <br />,-I <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: MJAMES <br />VERSION N0. 10 <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.