I I I III I I I I I t- 1 _ 1 14111111-_ I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSYI <br />BON <br />TERMINATION <br />NEC 14, 250.94 --/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to lights & outlets <br />tipper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />2 Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />w P WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />0 DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ WALL SWITCH <br />�3 THREE-WAY SWITCH <br />�?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />P.C. <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;ry EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />O PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />owl_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />GFI <br />WP <br />GFI <br />DISC. 4 <br />DPA <br />\ \ 11 11 11 <br />\ <br />\ <br />\ <br />\ <br />\ <br />\\\\ FAMILY ROOM CAFE <br />\ 12 PENDANT AS <br />1 ` PER SPECS r <br />6/ �— — ------------------------------------ <br />\ ROUGH -IN FbR `\ 7-0" <br />\ OPT. CLG. F�N/ LIGHT \ <br />\ PRE -WIRE \ <br />I IN, <br />' =E <br />I C.M <br />Fl <br />M Ak I — <br />/OYNER'S <br />SUITE <br />� G � <br />ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />ra". <br />W. I.C. — — <br />ENTRY <br />-- WP <br />GFI <br />!- <br />111SINK <br />�.I�• ��, <br />•. A <br />w <br />111 •I• i <br />O DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE G <br />HOOD PER SPECS <br />___ _ -! l __ -- <br />/ <br />ROUGH-IN11FOR� <br />OPT. CLG. IlAN/ <br />LIGHT PRE}WIT <br />BEDROOM 2 <br />S. <br />��HALL <br />(� IRRIGATION <br />GFI @ 44" A.F.F. <br />--� <br />I IF------------ <br />II 11 <br />I <br />II <br />I I <br />I <br />i <br />� <br />i <br />L_ YI -J <br />I <br />I <br />'GARAGE <br />GARAGE <br />I DOOR <br />\ <br />LIGHT AS <br />I GFI <br />\ <br />PER SPEC <br />GFI @err <br />\ IL <br />2 CAR- <br />' <br />A <br />A65' <br />J <br />oQ <br />QCL <br />O Q <br />■ <br />� U <br />I <br />W J <br />GFI @ 44" <br />A A.F.F. <br />S.D <br />I EDROOM 4 <br />�12 I I �12 <br />ROUGH -IN FOR ROUGH -IN FOR <br />LIGHT PRE WIREB E D �OO M OPT. CLG. FAN/ <br />\ LIGHT PRE -WIRE <br />3 <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN ELECTRICAL PLANT <br />SCALE: %4'=1'-0" <br />!P <br />Z M <br />O <br />CO <br />Z <br />Q <br />E3 <br />C.L_ <br />0 <br />^^V)' <br />� <br />w <br />w <br />~ <br />E <br />Cl) <br />T[ ~ <br />) <br />m � <br />V C� <br />4M M <br />E <br />— c0i <br />1�0 <br />O o 0 <br />_ <br />L LL 00 <br />U� <br />0Co <br />Q� <br />I <br />C 0 <br />Q'M <br />& <br />MQ O <br />CO <br />'s <br />� N <br />N_ <br />N_ <br />CV <br />O <br />Y�z <br />9A ZW N1 8 �MN <br />z o <br />z <br />_ °' _� <br />W O O <br />ILL <br />rn N <br />lL <br />a� <br />jaWa'�LL� <br />Q <br />z <br />Z <br />LLZ 2 <br />W N Q M <br />—' (=1 <br />O <br />O U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />Z <br />0 n <br />> <br />V) <br />M <br />a�-v�' <br />Z <br />HQ ^ <br />V Q00 <br />a <br />Z Ev <br />Z <br />W <br />�� <br />d' <br />�Z <br />W0 <br />Z d <br />aCL <br />W Q of cr <br />VZOp <br />ce <br />zt"jz� <br />Z� <br />(� <br />gJ Z <br />�gJ <br />z <br />UW <br />Z�© <br />o <br />z� <br />A <br />LL. <br />Q <br />2:Z <br />Z <br />-a <br />of <br />Q <br />CC <br />~ <br />O <br />V <br />U0 <br />�< <br />fQ <br />LU <br />J <br />W <br />0LLZ <br />tD <br />%.P! <br />O <br />Z <br />[V <br />Q <br />-,!a <br />Z, zWza <br />Q <br />g <br />Z <br />Z <br />N <br />u gooW <br />a <br />Wf <br />J <br />Lr) <br />t-4 <br />Lij <br />diQ�o0Z <br />Q� Z o <br />Y <br />Cr' <br />Q <br />W~Z <br />Ln <br />Z t � <br />m <br />OZ <br />Q <br />= <br />JO <br />a 9 <br />O <br />00 <br />_i <br />,-11 <br />a <br />U0 <br />SCALE : AS NOTED <br />DATE : 12/28/2017 <br />TECH: ERAND <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />