My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6645 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6645 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:10:49 PM
Creation date
2/27/2025 11:27:35 AM
Metadata
Fields
Template:
Building Plans
Street #
6645
Location
Wagon Trail St
Contractor
Lennar Homes
Building Plans - Permit #
19690
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES, <br />200A INDOOR PANEL <br />MO <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />NEMA1 <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped With an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />�—_ < <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />P TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F <br />O THERMOSTAT <br />Irl ELECTRIC METER <br />_a ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br /><\7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />C J <br />OPT. CEILING FAN <br />w <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. <br />GFI H <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn nrn c+nr_rna <br />SYSTEM <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />Z M <br />'— O <br />Q <br />J <br />a <br />(D <br />^Lo'' <br />�W w <br />Ow <br />~ <br />ct <br />0 <br />r— <br />i� C%i = <br />o r- <br />pp t` <br />V <br />0M M <br />t— <br />8 <br />C N <br />O <br />— <br />= <br />I U00 <br />oa <br />L L.L 30 <br />CL <br />�o <br />< <br />�0 <br />OL <br />0) <br />< <br />N <br />1 <br />� CV <br />1 <br />co <br />U5 <br />.w O ' a � <br />V p� Q Q SV <br />'Lou <br />co <br />O 00 <br />Z 0 <br />ZM m Z <br />� " U: o O <br />L . Z <br />LL <br />ii to N <br />W ; �� g <br />L.0 <br />a <br />W ••♦♦ <br />5 <br />Q <br />Ti. Oa rn rn <br />¢r5 <br />CD <br />to <br />m <br />� �ECP <br />Z d <br />¢ o <br />W Nam'`-e <br />J o <br />�d o <br />U U <br />U H <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />11 <br />0 <br />CD <br />Z N <br />O r\ <br />M <br />Q U-) f0 V) <br />LA <br />Q W IO Ln <br />CL <br />f— <br />U Q ,0 <br />Q00 <br />Z (D <br />Lu C:) <br />W <br />J <br />d- <br />J <br />�Z <br />Za <br /><a <br />N <br />L,Z80 <br />Q <br />J <br />zUJz¢ <br />tmwZ <br />J <br />�ir�w <br />Q <br />a o <br />UMWto <br />CU <br />� <br />W <br />°Z <br />aZo <br />g Z <br />O <br />W <br />3 <br />Ln <br />M <br />o <br />U <br />O <br />a <br />W <br />r <br />_ <br />O <br />J <br />o� <br />�0o <br />0 <br />V- <br />N <br /><[ <br />a o. <br />o¢oa <br />C <br />wiz¢ <br />�aa3 <br />�.1.. <br />.0 <br />z <br />N <br />uu_ia�LLo <br />w_I <br />Nr <br />-WEQO <br />l <br />di <br />Q <br />8 <br />ulpo <br />ZU <br />W U <br />Lu <br />I.n <br />Q Lu Z <br />�l <br />Ln <br />Z <br />a <br />Q <br />Z <br />Q o <br />0 <br />rn <br />00 <br />_I <br />= <br />?--1 <br />0- <br />U0 <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAND <br />VERSION N0, 10 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.