Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND <br />FLUSH TO THE OUTSIDE <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />CONNECTION <br />2x DEAD WOOD @ MID <br />POINT w/ (3)12d <br />TONEAILS SPACED <br />DOUBLE 2x TOP <br />EVENLY <br />PLATE <br />J <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />W/lz/ (2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />VARIES O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL <br />SCALE: N.T.S. SL� <br />12 <br />SEE TYPICAL WALL SECTION <br />(TYp) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />USP SPT24 @ EA. STUD <br />(3) 10d TOENAILS T&B <br />AS REQ'D <br />2x BLOCKING @ MID <br />POINT EVERY OTHER <br />F.AILS <br />'��STTUD W/ (3) Od N <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />USP SPT22 @ EA. STUD <br />2x P.T. PLATE — I \\ <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD, 90A HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />\—ROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />ZSEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />1/2" MINIMUM CEMENT FINISH <br />STANDARD 3" DIA. TEE <br />THREADED 3" DIA. EXTENSION <br />SCREW OFF CAP (3" DIA.) <br />FOR CLEAN -OUT <br />MIN. EXTENSION FROM <br />EXTERIOR FACE OF BLOCK <br />WALL IS 1 1/2" MAXIMUM <br />EXTENSION FROM EXTERIOR <br />FACE OF BLOCK WALL IS 21/4" <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />WALL CLEAN -OUT rA <br />SCALE: N.T.S. S4 <br />REFER TO WINDOW PRODUCT APPROVAL <br />SHEETS FOR INSTALLATION INFORMATION BY <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT 7 <br />° <br />g" STD. 90 HOOK g <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6'-0" WIDE (U.N.O.ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />10 FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />2� VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY, <br />g SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO 6'-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" <br />FORM CONCRETE INSET TO <br />1/2"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR <br />BLOCK WALL ABOVE. <br />SCRAP MATERIAL <br />MOUNTING BASE SHOWN <br />IN POSITION <br />—2x6 MOUNTING BASE <br />J <br />CC <br />Uj <br />0 <br />FORM CREATES CONCRETE RECESS TO <br />2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />�8x8x16 C.M.U. GARAGE DOOR----_ <br />GARAGE DOOR ROLLER <br />CONNECTION ASSEMBLY <br />.., GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />-TRACK MOUNTING BRACKET <br />GARAGE DOOR TRACK <br />SCALE: N.T.S. d <br />a o POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />q <br />SOLID AREAS ARE ❑ <br />❑ STEEL AND GROUT ❑ . <br />INTERIOR <br />WALL ❑ ❑ ❑ <br />CL DOOR OPENING DOOR OPENING <br />EXTERIOR ❑ ❑ <br />WALL ❑ ❑ ❑ <br />❑FIJI <br />❑ <br />1ST COARSE 2ND COARSE 3RD COARSE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />MASONRY LAYOUT D <br />SCALE: N.T.S. S4 <br />VERTICAL JAM <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />EBLOCKING <br />USS BOTTOM CHORD OR 2x4 TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />W/ 2-16d TOE NAILS NOT TRANSFER LOAD. <br />EACH END WALL <br />a d ° <br />° DOOR STOP <br />w ° a <br />0 ° MOLDING <br />�za ° <br />2x TOP PLATE GARAGE <br />V2-16d <br />NAILS @ 24" O.C. OR ZI DOOR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING 2 x 6 P.T. <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE EQUAL @ 12" O.C. <br />SEE A/S3 FOR STAGGERED FROM BOT. <br />PLATE TO CONCRETE <br />REINF. INFO. W/MOUNTING ANGLE <br />° NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 SCALE: N.T.S. S4 <br />T <br />S��IA <br />2x CRIPPLES @ <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />USP SPT4 w/ (6) <br />10dx1'/2"@24" <br />O.C. <br />10d NAILS @ 8"— <br />O/C TYP. <br />DOUBLE 2x—� <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />HEADER SUPPORT <br />NO, OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) USP LSTA30 <br />4' - 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) USP LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) USP LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE "'" HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />1� GREATER HEADER <br />1 (2) 2x HEADER SEE PLAN <br />S4 INTERIOR HEADER <br />BOX HEADER (1) 2x SILL PLATE W/ (2) <br />ONLY 12d TOENAILS. <br />EXTERIOR HEADERS <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS. OPENING <br />LARGER THAN 4 ft (2) 2x <br />SILL PLATE W/ MP3 CLIPS <br />EACH SIDE <br />'--2x STUDS TYP. <br />USP HTT16 TYP. U.N.O. SEE N/S <br />** HOLD DOWN CONNECTIONS <br />Op��O,Q NOT REQUIRED @ BEARING <br />F�ViyC WALLS NOTED WITHOUT UPLIFT <br />P.T. BOT. PLATE <br />WALL HEADER DETAIL Q <br />SCALE: N,T.S. SL� <br />-USP SPT4 SPT24 <br />lisp 111" <br />2X STUDS @ 24" O.C. <br />P.T. <br />ATE <br />SEE TYPICAL WALL SECTION <br />12 PRE-ENGINEERED WOOD TRUSSES @ 24" O/C <br />(TYP.) SEE ELEV. UPLIFT CONNECTOR (SEE SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS <br />7/8" OVER METAL LATH. FIRST 2 <br />LAYERS 3/8" THICK EACH. 3RD LAYER <br />1/8" THICK. <br />i—CRICKET AS REQUIRED <br />USP SPT24 @ EA. STUD <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING7(.) <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />USP HTA20 @ EA. STUD <br />MAIN SPAN <br />MOISTURE BARRIER <br />ROOF TRUSS <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90° HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY <br />WALL DETAIL / <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12) 16d NAILS <br />TOP SPLICE <br />2 ROWS 10d @ 3" O.C. (14 <br />NAILS TOTAL) EA. SIDE OF <br />48„ SPLICE STAGGERED <br />. ' 10d @ 8" O/C <br />ATTACH ALL <br />EXTERIOR STUDS <br />W! 4 16d TOENAILS <br />TO'fbP PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL �Ai <br />L <br />SCALE: N.T.S. S4 <br />F= 2240 LBS �7 <br />USP SPT4—i USP C USP SPT4 <br />SCALE: N.T.S. <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 <br />AND BB/S1 FOR <br />ADDITIONAL DETAILS <br />/RECESS <br />/ LINTEL <br />INTO <br />TRANSOM <br />FRAMING <br />rUSP SPT22 <br />P SPT4 I USP SPT4 <br />10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />A ° 2X8 P.T. BOTTOM P ATE <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />USP <br />USP SPT4 <br />SPT24 <br />USP S <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />USP <br />SPT22 <br />RECESS <br />SP <br />LINTEL <br />SPT4 <br />U <br />S <br />° d <br />° <br />° 2X8 P.T. BOTTOM <br />PLATE <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />ROOF TRUSS ABOVE <br />2X BLOCKING <br />0 <br />-(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />MASONRY WALL <br />PT4 <br />10d NAILS @ 4" A 10d NAILS @ 6" O.C. <br />STAGGERED STAGGERED <br />TRANSOM FRAMING <br />0 o BEYOND. <br />LPLYWOOD <br />o E SHEATHING <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" S4 <br />O/C BOUNDARIES 6" O/C EDGES B <br />& 8" O/C FIELD <br />PLYWOOD <br />SHEATHING <br />MASONRY <br />— <br />WALL WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />PT4 MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY R <br />SCALE: N.T.S. S4 <br />120 <br />z� <br />0 <br />Z <br />z <br />Q <br />J <br />a <br />U, z <br />V) (D <br />cn <br />LU <br />p <br />0 "J <br />E <br />tip '— <br />o I� <br />C <br />w <br />pp <br />— U <br />N cc ) <br />cmM <br />NUCM <br />O 0 N <br />2 <br />U <br />wc u-coo <br />ca <br />ao <br />Q� <br />��o <br />N C B D C <br />�� <br />cs <br />!N <br />co N <br />o <br />ZN ��'s14Stt <br />" <br />�, <br />C•��� <br />m <br />ag ut <br />�N <br />To the best of � Engi eer's°kpo le e, infpinati an <br />belief, the strut I pl nd sp�tif"itsti8 ns co %Wned \ <br />within these dra co i 0 a <br />!� <br />Building Code - Res Poo6th E Yq�-9�n ne e{\� <br />signature and seal is orSlystructu ra($��1��Ying <br />portions of the drawing pag �AtiftI lk s signature <br />and seal. <br />O <br />O <br />z c11 <br />O a) N <br />> V) m O <br />M <br />Q M Ln <br />Ln <br />Q �' U_ <br />z <br />M <br />Q U CL 00 <br />a <br />z E <br />W <br />z <br />JkD <br />R <br />W0 <br />zaa <br /><a <br />Wa�-e-W <br />�zgo <br />2 W � l Y <br />_ So w z <br />��E� <br />}a�Eo <br />SmoU <br />T <br />oZ <br />Z O <br />1 <br />QU <br />� Z <br />0 <br />z <br />Lo <br />N <br />O <br />� <br />L <br />a <br />V <br />[V <br />U) <br />J <br />W� <br />ou <br />l- o <br />I- <br />0 <br />Q <br />2: 2 <br />Wo8 9 <br />LJ.1 <br />21 <br />N <br />N. <br />C) <br />zgoa <br />W � J <br />;aZ� <br />a <br />V_ <br />o��g <br />Z <br />Z <br />N <br />uuaio <br />J <br />' <br />LLJ <br />2 <br />U Q o <br />spa <br />d" <br />¢ <br />Z <br />W <br />yu <br />Lin <br />Z <br />=z <br />a <br />Ln <br />co <br />O <br />co <br />Z <br />LU <br />J o <br />T-I <br />a <br />(n <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: MJAMES <br />VERSION N0. 2 . C <br />SHEET NO. <br />S4 <br />