My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6653 Wagon Trail St
Zephyrhills
>
Building Department
>
Building Plans
>
6653 Wagon Trail St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:03:14 PM
Creation date
2/27/2025 11:27:59 AM
Metadata
Fields
Template:
Building Plans
Street #
6653
Location
Wagon Trail St
Contractor
Lennar Homes
Building Plans - Permit #
19685
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />PE�FW.P. <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />�� JJ <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 #1 <br />200 AMP 2 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MO v <br />2!0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />"WWI EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) FO SYSTEM <br />0 PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />C1MI ELECTRIC METER <br />NP71_ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />G�) <br />(1) PHONE LINE, (1) DATA PORT <br />I 1 <br />L <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />r—� <br />I I <br />UPPER ELECTRICAL PLAN <br />SCALE: Y4"=V-0" <br />z o <br />U) <br />Lnn' U <br />� <br />LU <br />O <br />LU~ <br />0 C2—, <br />0 <br />= <br />Cn <br />�V) I— <br />o0 <br />m � <br />a co Cl) <br />F <br />amp <br />C N CM <br />O _O N <br />_ <br />�i <br />U. 00 <br />oo <br />U)Qo <br />L� Y <br />< rn <br />l�!{) O <br />CL <br />Oi Q O <br />NCBDC]. <br />OQ <br />N <br />co <br />�j N <br />O m <br />42 U) NZ <br />U) N IIiNO <br />toNJA0 <br />zIU <br />- <br />� <br />.W <br />LL <br />W <br />} Q <br />W O v rn <br />10 <br />U z <br />cn <br />yy <br />._ww <br />V� m nZ-) <br />m m <br />1j. Z <br />N Wa� <br />o � <br />= o <br />U F- <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z N <br />O a) n <br />r-4 4-+ p <br />I>-tp <br />0 h <br />Q U_ <br />V a00 <br />a <br />E <br />Z <br />WJ <br />0 <br />J <br />oZ <br />o <br />�2 <br />za <br />fa <br />F <br />z <br />a�� <br />Q <br />oW0o <br />CL <br />w <br />tEgZw <br />w <br />Q <br />8LU <br />s �8 <br />c) <br />U uj <br />ZZ <br />o <br />Z <br />-0 <br />Lr) <br />W <br />4 3 <br />f <br />1 ` <br />LJ <br />F_ <br />o <br />0 <br />> <br />Ln <br />rr <br />o <br />O <br />U <br />Ln <br />N <br />�a <br />O <br />I, <br />U <br />uj <br />o <br />pz <br />a <br />Q <br />J- <br />_ <br />Z <br />Y P <br />QQ <br />LUU <br />�0.C, <br />A <br />Z <br /><C <br />$�Z� <br />Z <br />Z <br />N <br />u_ g o! <br />a 5 <br />a 1 0'Z <br />Jri <br />Lr)di <br />H-`1`:,:, <br />W <br />izz� <br />Q <br />Z <br />dl0- <br />W , Z <br />Z <br />OZ <br />t <br />�N <br />�Z <br />Z <br />-2 <br />` Z <br />0 <br />oo <br />g <br />= <br />Uj <br />,--'I <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.1 <br />