ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />MAIN <br />O <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER J <br />NEC 08, 250.94 <br />NEMA1 <br />200 AMP <br />#14 copper to fights & outlets <br />#12 copper to 20 strip clas <br />#10.2 copper to WH <br />#10-3 copper to Dryer <br />or 410 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FFF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />PG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />d <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />} <br />�fO <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />® <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />rD <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />PP7 <br />ELECTRIC PANEL <br />J <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />�7 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />C J <br />OPT. CEILING FAN <br />ET) <br />(1) PHONE LINE, (1) DATA PORT <br />III 3" VTR <br />2" VTR `III <br />I <br />SINK I I KITCHEN <br />I I SINK W/ STUDOR <br />I \� <br />I I 31' III 2" VTR I I <br />rr I WC 3"3 T0J13 3" j <br />SHWR I �� 3' 31r SINK I I <br />1.5" VTR III, 3rr 2rr <br />-I <br />I I I WC <br />3" <br />3" I <br />TUB <br />3" <br />SINK I I <br />I <br />HANSON BOX 3" <br />WC <br />4" TUB <br />4" <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />/ <br />SWITCH FOR <br />DISPOSAL <br />I IAnk <br />' <br />Q <br />FI <br />I <br />2 X 4 FL. <br />GFI <br />UNDER <br />II <br />CNTR TOP <br />I <br />I I® <br />I p <br />II <br />I <br />II <br />I —Fly <br />� <br />/ <br />16 <br />PENDANT <br />2 X 4 FL. <br />GFI <br />LIGHTS OVER <br />ISLAND <br />/ <br />I <br />f <br />I <br />1�7 <br />3 <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />OPTIONAL LIGHTING <br />SCALE: 1/4"=V-0" <br />C/O <br />1 <br />A/C PAD <br />WP <br />DISC. GFI <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />ALT. <br />A/C �I <br />l PAD <br />\ r'KCVVIKC HJ YCK { } <br />SPECS i/Vf <br />ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />0 to <br />Z M <br />— o <br />Z19 <br />z <br />rriqs <br />CL <br />C <br />W N <br />W <br />0 <br />U <br />O LU LU <br />= <br />o <br />Cl) <br />v J F— <br />O <br />m 04 <br />04 <br />U <br />W <br />H <br />— 8 <br />a)M <br />C W cM0 <br />N C <br />O `oo <br />W <br />, <br />LL00 <br />0 <br />Yco <br />CL <br />in 0 tt <br />Q rn <br />4 0 <br />A' <br />B Ds <br />N•C�e D C <br />ti <br />N <br />N <br />io CC) <br />V o <br />Z W � C4 Z <br />Z <br />LL Ci <br />Z <br />/y r iL <br />N <br />IIIV ..LL <br />W i.i_ <br />dUj <br />_ <br />' <br />LU V-0cnco5O <br />CL <br />z <br />Z <br />o 0 <br />022 <br />I= <br />Q � <br />LL <br />LU N Q Cl) 'E <br />Q <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />i <br />O <br />O <br />Z 2V <br />O cur-, <br />t-� a_+ O <br />�>-+HMO <br />M <br />EON <br />Q LL <br />a <br />f— <br />l� U Q 00 <br />Q <br />E <br />Z <br />WJ <br />C:) <br />f <br />oZ <br />ZCe <br />wmZ am <br />U 1— 0 <br />Zr0 U <br />a <br />ZQ<UZ< <br />�S�?WZWFZ <br />UZ0Cdw <br />g <br />a U O p <br />o4o��o <br />U= ow 5 W i V <br />W <br />J <br />O <br />3 <br />L1n <br />N <br />Lrn <br />rl <br />� <br />J <br />LU Q Q <br />uj <br />WiaAY0� <br />Q <br />o <br />-a <br />Z <br />Q Q <br />J <br />�iA-, <br />Uoz�� <br />ED IX <br />oU2:O <br />M <br />N <br />Z <br />^ a <br />g+ <br />fO-z <br />w�pZ—Op <br />~�wa� <br />J <br />J <br />QW <br />$g���a <br />o w Z <br />V� <br />w Q <br />�aQoS <br />A/ <br />Xu_Z <br />Q <br />O <br />-10 W <br />.1 CLYW <br />¢ <br />z <br />�N <br />U <br />< u- <br />w <br />> <br />~ <br />J <br />g <br />Z <br />0 <br />a w <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />106 <br />JOB NO: 17-5179 <br />SHEET NO. <br />3 <br />