My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6671 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6671 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:39:14 PM
Creation date
2/27/2025 11:28:23 AM
Metadata
Fields
Template:
Building Plans
Street #
6671
Location
Paden Wheel St
Contractor
Lennar Homes
Building Plans - Permit #
19501
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br />12 <br />PITCH AS <br />PER <br />ELEV. <br />50# FELT OVER <br />METAL FLASHING <br />SHINGLE ROOF, U.N.O PER <br />CONTRACT <br />TYPICAL VALLEY FLASHING DETAIL <br />N.T.S. <br />3 TAB 25 YR SHINGLE ON APPROVED <br />UNDERLAYMENT ASTM D 226 OVER <br />ROOF SHEATHING SPECIFIED ON <br />NAILING SCHEDULE ROOF OVER <br />PRE-ENGINEERED ROOF TRUSSES @ <br />24" O.C. <br />HURRICANE STRAP PER <br />ROOF FRAMING PLAN <br />BRG. HGT. <br />ALUM. DRIP EDGE <br />2x6. FASCIA <br />VENTED ALUM. SOFFIT <br />SHEATHING & EXTERIOR FINISH <br />WINDOW FLASHING AS REQ'D <br />1x4 WINDOW TRIM <br />DBL.HEADER <br />TYPICAL WINDOW & SLIDING GLASS <br />DOOR Z FLASHING DETAIL. <br />N.T.S. <br />OPTION - A <br />FLASHING <br />WOODEN <br />SHIM <br />r- SILL PLATE <br />SEE NOTE #2 <br />WALL SHEATHING <br />NOTES: <br />1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) <br />2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW SILL PLATE <br />3. INSTALL SILL FLASHING AS SHOWN ABOVE <br />4. INSTALL FLASHING AROUND REMAINING WINDOW UNIT <br />5. WEATHER RESISTIVE BARRIER TO FORM WATER SHEDDING LAPS <br />I TYPICAL FLASHING DETAIL AT SILL PLATE <br />N.T.S. <br />TIE-IN WITH WEATHER RESISTIVE BARRIER: <br />1. INTEGRATE INSTALLATION OF WEATHER RESISTIVE BARRIER WITH <br />FLASHING TO FORM WATER SHEDDING LAPS <br />2. SCORE & FOLD WEATHER RESISTIVE BARRIER ABOVE HEADER TO <br />ALLOW FOR FLASHING INSTALLATION <br />4. INSTALL HEAD FLASHING UNDER WEATHER RESISTIVE BARRIER <br />5. FOLD WEATHER RESISTIVE BARRIER BACK OVER HEAD FLASHING <br />AND SEAL WITH WEATHER RESISTIVE BARRIER TAPE <br />FLASHING <br />TYPICA <br />N.T.S. <br />MECHANICALLY FASTEN AS <br />NECESSARY IN CORNERS <br />THROUGH FLASHING <br />WEATHER <br />RESISTIVE <br />BARRIER <br />TAPE <br />(ASSEMBLED <br />DWINDOW) <br />D <br />= <br />x <br />G) <br />G) <br />FLASHING <br />WALL PER PLAN <br />6" <br />RUN KICKOUT FLASHING 6" - <br />PAST EDGE OF ROOF <br />TYPICAL ROOF TO WALL FLASHING DETAIL <br />N.T.S. PLAN VIEW <br />EXTERIOR SHEATHING <br />��ThF FOLD UP WEATHER <br />R RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />RFs�s <br />�i WEATHER RESISTIVE <br />BARRIER <br />\S <br />SILL PLATE <br />(SEE DETAIL B' <br />O O FOR OPTIONS) <br />P� <br />CORNER PATCH <br />FLASHING <br />NOTES: <br />1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE <br />(MIN. 6" WIDE) <br />2. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS <br />3. MECHANICALLY FASTEN AS NECESSARY <br />OR FLASHING DETAIL_ <br />CEMENT <br />WEATHER FOLD UP WEATHER PLASTER FINISH <br />RESISTIVE RESISTIVE BARRIER & <br />BARRIER TEMPORARILY SECURE WIRE LATHE- <br />HOUSE WRAP - <br />TO OVERLAP <br />FLASHING <br />EXTERIOR <br />SHEATHING <br />SILL PLATE <br />2 <br />DO NOT FLASH - <br />OVER BOTTOM <br />NAILING FLANGE <br />HEAD FLASHING TIE-IN <br />INSTRUCTIONS: <br />1. CUT, FOLD UP & TEMPORARILY <br />SECURE WEATHER RESISTIVE <br />BARRIER ABOVE HEADER TO <br />ALLOW FOR FLASHING <br />INSTALLATION <br />2. INSTALL HEAD FLASHING UNDER <br />WEATHER RESISTIVE BARRIER <br />3. FOLD WEATHER RESISTIVE <br />BARRIER BACK OVER HEAD <br />FLASHING AND SEAL WITH TAPE <br />1 <br />FLASHING HOUSE WRAP - <br />WIRE LATHE - <br />CEMENT <br />PLASTER FINISH <br />NOTES: <br />1. FLASHING TO BE FLEXIBLE SELF-ADHESIVE TYPE (MIN. 6" WIDE) <br />2. REMOVE WEATHER RESISTIVE BARRIER FROM TOP OF WINDOW <br />SILL PLATE <br />3. INSTALL FLASHING IN ORDER AS SHOWN BY NUMBERS <br />4. INSTALL FLASHING AND WEATHER RESISTIVE <br />BARRIER TO FORM WATER SHEDDING LAPS <br />TYPICAL WINDOW FLASHING DETAIL <br />N.T.S. <br />3-HEAO <br />I FLASHING <br />SLOPE <br />SHIM TO <br />-- <br />PROVIDE SLOPE <br />HOUSE WRAP <br />WIRE LATHE <br />el <br />CEMENT <br />_ <br />PLASTER FINISH <br />5"x5" METAL FLASHING <br />w/TAR BETWEEN <br />FLASHING AND SHINGLES U.N.O. <br />SHINGLE, <br />U.N.O. PER <br />CONTRACT <br />TYPICAL ROOF TO WALL <br />FLASHING DETAIL <br />N.T.S. <br />FLASHING <br />FORMED CAP <br />HOUSE WRAP <br />WIRE LATHE <br />CEMENT <br />PLASTER FINISH <br />CAP a@ LOW WALL <br />N.T.S. <br />WALL COVERING <br />2014 FBRC SECTION R703 EXTERIOR COVERING <br />EXTERIOR WALLS SHALL PROVIDE THE BUILIDNG WITH A WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE <br />EXTERIOR WALL ENVELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.8. THE EXTERIOR WALL <br />ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER -RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER AS <br />REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO THE EXTERIOR WALL THAT ENTERS THE ASSEMBLY. <br />PROTECTION AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY SHALL BE PROVIDED IN ACCORDANCE <br />WITH SECTION R702.7 OF THE CODE. <br />R703.2 WATER -RESISTIVE BARRIER <br />ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM HOLES AND BREAKS, COMPLYING WITH ASTM D 226 FOR TYPE 1 <br />FELT OR OTHER APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />EXTERIOR WALLS. SUCH FELT OR MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED <br />OVER THE LOWER LAYER NOT LESS THAN 2 INCHES (51 MM). WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT <br />LESS THAN 6 INCHES (152 MM). THE FELT OR OTHER APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF <br />WALLS AND TERMINATED AT PENETRATIONS AND BUILDING APPENDAGES IN A MANNER TO MEET THE <br />REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />R703.8 FLASHING <br />APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT <br />ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING <br />COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR <br />FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT <br />COMPLYING WITH AAMA 800 OR ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND <br />CONTRACTION, ASTM C 1281, AAMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF <br />SEALANT. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED <br />CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: <br />1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENT <br />DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE <br />OR MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT <br />ADDRESSED IN THE FENESTRATION MANUFACTURER'S, IN ACCORDANCE WITH THE FLASHING MANUFACTURER'S <br />INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE <br />SILL OF EXTERIOR WINDOWS AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A <br />WIRE LATHE <br />MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE <br />CEMENT <br />BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OR <br />PLASTER FINISH <br />PROTECTION AT THE HEAD AND SIDES. <br />FLASHING <br />CEMENT <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL. <br />PLASTER FINISH <br />HOUSE WRAP <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA 250„ OR FMA/AAMA/WDMA 300. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. <br />M 00 N <br />� � <br />1J� 1 <br />N 2 <br />yJcoN v <br />a r{LL <br />r- <br />'r O. X <br />Wi <br />a M � <br />S <br />td$ <br />3 <br />7 <br />~ <br />s <br />M W <br />�z <br />DA�OON <br />R1-+ <br />S <br />W� <br />to <br />V1� Arc <br />W <br />9�0 <br />�- <br />U S <br />❑ <br />W <br />� <br />N <br />r <br />gym Z <br />Z �2la�o <br />W �,� <br />O SON w <br />Paz <br />` <br />as <br />0 <br />Z <br />z{p <br />4rn 0 o <br />�N <br />�] <br />o <br />UJ W LLI ix <br />U <br />U El <br />I�IO�'iJ1VSSQrI'/1A4AM <br />n <br />CY) Q <br />Q N 0) <br />c� <br />G w N <br />Z I <br />00 <br />N� r <br />I..L <br />Q o <br />z <br />z Z 0 <br />L.U� <br />� W <br />VJ <br />FOLD UP WEATHER 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />BARRIER AND 8 <br />TEMPORARILY 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME to <br />� title: <br />CONSTRUCTION. FLASHING DETAILS <br />U <br />WEATHER BARRIER 6. AT WALL AND ROOF INTERSECTIONS. o <br />project no. 2017556 <br />7. AT BUILT-IN GUTTERS. S <br />FLASHING <br />WALL OPENING <br />N.T.S. <br />9 checked: AB/MC <br />mg drawn: <br />LO date: 10-09-17 <br />r, <br />N scale: AS NOTED <br />0 <br />H <br />a WP1 <br />0 <br />0 <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />a-c ran k.. , m W yin: -Tre"r, ;1116,1--r:r-- rr i i I i ---- 7� <br />
The URL can be used to link to this page
Your browser does not support the video tag.