Laserfiche WebLink
- - - - - - - - - -° GENERAL CONCRETE LINTEL SCHEDULE ALTERNATE POWERS DISCLAIMER <br />• OPENING PRESSURES L ti m o <br />o - - APPROVED LINTEL MANUFACTURERS CASTE-CRETE, ENCLOSED - EXPOSURE "C" M 00 N N <br />O O O O '' '' •' ' QUALITY STEEL LINTEL IT IS THE CONTRACTOR/SUB-CONTRACTORS RESPONSIBILITY TO REVIEW ALL rn <br />8F8-1B/1T 8F8-0B/1T A +29.7 / -37.2 B +29.7 / -39.6 . r <br />O INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF L °O 0 <br />CONSTRUCTION. B&A DESIGN STUDIO, INC. & FLORIDA DESIGN SOLUTIONS INC. o <br />TYPE DESIGNATION 11 REBARATTOP #5REBARATTOP IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR X <br />F =FILLED WITH MIN. (1) REQ'D MIN. (1) REQ'D d © +28.4 / -30.9 O +28.4 / -37.0 r` o <br />Q 1-1/2" CLEAR CL X <br />O CUSTOM CHANGES MISSED AND NOT REPORTED TO B&A DESIGN STUDIO, INC. & <br />GROUT / U = UNFILLED c 1/z' p M <br />8RF14-1B/1T 8RF14-OB/1T R RECESSED CLEAR O +26.6 / -29.1 OF +26.6 / -33.5 FLORIDA DESIGN SOLUTIONS INC. PRIOR TO CONSTRUCTION. / U <br />Zoo' a ' QTY. OF #5 e o NO EXCEPTIONS. <br />• ' • • REBAR @ BOTTOM p Q <br />OF LINTEL CAVITY M� Q © SEE SN SHT. O SEE SN SHT. .� <br />U e W �� R <br />a e d C.M.U. 140 MPH ??J <br />•, '• '' Q U c N. <br />�U u) • <br />6- BM T Lo <br />� e a � ��; ' .4 - NOTE: WIND SPEED INDICATED ABOVE` <br />';,' Z GROUT 0 0 ,� IS AN "ULTIMATE" WIND SPEED. THE <br />L <br />o°. LNOMIN tQUANTITY OF 5REBARAT ��aN = = WIND PRESSURES LISTED ABOVE ARE <br />O O O r O O O WIDTH #5 REBAR AT a O ¢, <br />BOTTOM OF Q O D D <br />TOP LINTEL CAVITY o w O u 5 REBAR AT BOTTOM ALLOWABLE PRESSURES <br />8F20-0B/1T 8F20-1B/1T 8F16-OB/1T 8F16-1B/1T NOMINAL o aa?= <1 Q AS INDICATED <br />OTTOM � w 00 A 0 a <br />---------------J © © O O HEIGHT REINFORCING -~w Q 6-6 1/2" n ' <br />7-5/8"ACTUAL PROVIDED IN <br />8" NOMINAL WIDTH LINTEL <br />::.° . ° °. O . ;: a., . O •(VARIES)STEEL BOXED LINTEL <br />16 GAUGE POWERS O <br />, <br />• r . <br />• �,, •,, •,, � MATERIALS1. precast ntels = 3500 psi. POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />O O 2. fc prestressed lintels = 6000 psi. s O I r i <br />3. grouted per ASTM C476 fg = 3000 psi w/ 1. Refer to manufacturer's specifications for installation. <br />8RF6-OB/1T .. e <br />4. maximum 3/8" aggregate and 8" to 11" slump. 2 I <br />- . Contractor to provide proper protection of lintel to prevent rusting. <br />O •: • 5. Concrete masonry units (CMU) perASTM C90w/ Po eel for u <br />P P <br />L• • = .. • . , . : Refer to manufacturer's specifications. I <br />• minimum net area compressive strength 1900 psi.3. If lintel is scratched or damaged refer to Powers St repair. <br />s t <br />• ' • , , , ; . , , ; ; . , ,•; 6. Rebar per ASTM A615 Grade 60. 4. Lintel depth to match precast depth. One #5 Bar required at top <br />Prestressing strand per ASTM A416 grade see lintel plan/details for bottom steel required. ? E z <br />7. 270 low relaxation. I i O <br />5. A bonding agent must be applied to the Steel Box lintels prior to € a, <br />Q , . O O % .. : 8 32 wire per ASTM A5 0. applying the cemenfitiuos coating. See contractor specifications 7'-0" 5'-8 7/8" a � 0 <br />r . : . Mortariper ASTM C2701type M or S. IL o, <br />8F20-1 B-2T I <br />GENERAL INSTALLATION NOTES i s <br />O O O O <br />• %' © 8F24-OB/1 T 8F24-1 B/1 T Provide full mortar head and bed joints. <br />8 R 1 T 1 t <br />• 2. Shore filled lintels as required. <br />• ' . • ,. • , . , ,, • � , , � O O 3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate t € -------- <br />' vertical cell reinforcing and grouting. <br />' • • ' . • . • . . • . • 5. All lintels meet or exceed U360 vertical deflection exceptlintels 17'-4" and I I ' r <br />�', longer with a nominal height of 8" meet or exceed U180. I O - <br />' . • 6. Bottom field added rebar to be located at the bottom of the lintel cavity. - <br />' • ' . • • ' • ' �: • • 7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete Iw I O <br />' ' ' ` ',' ,'. ' ` '• ' ' • ' ' ' • ' ' . • . Safe d ratings based on rational design analysis per ACI 318 and ACI 530 "'�`" - "'"" i <br />r .. • r . r , . r r , , r _ <br />, <br />• , � � • � .� •,• � : Product Approvals MiamiDade County, Florida Nos 03-0605 05 and 03 0605 04 <br />„ 4 <br />II <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have m <br />` ' a coating of stucco applied in accordance with ASTM C-926 or other approved O t 8 cw`a <br />%- coating. O o @•C✓ 3y. rI <br />' . • , , ' •, •, • , 12. All lintel dimensions shown are "overall" lintel lengths. <br />t •, N <br />% • • =� • % . • =� % . • :� ; .. ' ; .. :� 13. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) r O i z N� c'z <br />loads shoud be checked for combine loading with the following equation: (� •, <br />'' ' ' - ' • ' . •, ' . • Applied vertical load Applied horizontal load w �' <br />Safe vertical load + Safe horizontal load I F $ o o W <br /><1.0 g I _ 2 Z U9�_Z <br />,`O•' , , ,O• '�••, Q°,, I I � t °'m� 14 <br />� d��W G�'SP�v � <br />O O O O O O O O O O O O O O O O <br />l� C: o �.` <br />OF441B/1T8F400B/1T 8RF400B/1T 8F321B/1T 8F320B/1T 8RF301B/1T 8F28OB/1T 8F281B/1T s d Z o ,�W 9F..SS. <br />® © ® 0 ® 0 0 ZQ <br />90 W, �- <br />I o gH a o <br />' �LL C) Uw <br />t I Iw U ❑ <br />s I <br />OO I � j ' N InIOJ'rJN3SQ3'MMM <br />Am- <br />I� <br />sl D <br />D o <br />0 <br />I i 0 <br />I <br />€ I I _ LU <br />® L_ _J I a <br />c z <br />1 LU <br />z <br />z <br />LPL <br />I € o <br />' I I 0 LU <br />Q J <br />0 <br />L <br />I I - _ I o Q CV F t i s I 0 <br />I ll a <br />� � CV <br />o <br />Q LLJ <br />f3 3 lid € 3 W <br />I M <br />_- - w 00 <br />k / O _ < OI <br />I <br />Z <br />I - P p <br />i L <br />4_ x U w Q <br />�I € <br />.W I J <br />I <br />of <br />m <br />1 J W <br />( _:� _ w� <br />- I I N <br />0 <br />af <br />J <br />Lu <br />z <br />g�I I It r 1 3 O I LU <br />LU <br />I w <br />0 <br />w <br />LINTEL PLAN NOTES: E <br />z <br />U <br />_ <br />I I <br />I O 1- THIS PLAN IS TO BE USED FOR STRUCTURAL INFORMATION I <br />I O O co <br />ONLY. co <br />} �wW 2- UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE TO BE 0 <br />ASSUMED TO BE 16" MINIMUM DEPTH. I w <br />3- THE NUMBER OF COURSES OF MASONRY REQUIRED BETWEEN <br />- THE LINTEL & THE BOND BEAM SHOULD BE COORDINATED WITH I _ <br />1 THE ELEVATION DRAWINGS I I Iof <br />0 <br />4- THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING <br />THE PROPER LINTEL HEIGHT. I z I > title: <br />t 5- LINTELS AT GARAGE DOOR OPENING ARE MINIMUM DEPTH II Its LINTEL PLAN W/ LANAI <br />i I REQUIRED FOR THE DESIGN LOADS. THE DEPTH MAY BE I E OC Ohl T Z <br />INCREASED IF REQUIRED FOR PROPER LINTEL HEIGHT,G.C. I, o <br />l I COORDINATE. If III Z <br />I project no. 2017556 <br />0° 5'-2 1/8" 3'-6" I g 9'-3° 6'-7° w checked: AB/MC <br />r <br />POWER STEEL LINTEL IS AN ADEQUATE I I14 m drawn: <br />I I .. W_ l <br />I SUBSTITUTION @ALL LOCATIONS UNLESS � LO date: 10-09-17 <br />o <br />NOTED OTHERWISE AT OPENING LOCATION a scale: AS SHOWN <br />C�) no <br />SECOND FLOOR PLAN FIRST FLOOR PLAN <br />3/16"=1'-0" LINTEL & COMPONENT DESIGN PRESSURE PLAN 1/4"= 1'-0" a <br />U <br />S4ml <br />The structural design of this building is in accordance with the FLORIDA BUILDING CODE 5TH EDITION (2014) RESIDENTIAL and is certified as such. <br />TF i I - TI-Ti- - - - <br />