My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6671 Paden Wheel St (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6671 Paden Wheel St (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:55:34 PM
Creation date
2/27/2025 11:28:37 AM
Metadata
Fields
Template:
Building Plans
Street #
6671
Location
Paden Wheel St
Contractor
Lennar Homes
Building Plans - Permit #
19501
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />10 M14 copper to lights 8 outlets <br />NEMA 1 <br />200 AMP <br />10 p 12 copper to 20 amp ckts <br />00 A 10-2 copper to WH <br />a 10-3 copper to Dryer <br />METER <br />MAIN <br />O <br />2/0 or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />------------------------------------------------ <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />KG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />} <br />'O <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />—� <br />FLOURESCENT LIGHT FIXTURE <br />DISCONNECT <br />Q <br />EXHAUST FAN <br />GFI <br />url <br />rl <br />_Vill <br />;O <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />DEDICATED RECEPTACLE VERIFY METER <br />FOR MICROWAVE RANGE <br />CH 1 <br />CHIMES (OPTIONAL) <br />LOCATION WITH <br />HOOD PER SPECS BUILDER <br />O <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />—Elk=L <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />6D <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %41=11-0" <br />CD <br />Z th <br />— O <br />z� <br />Q <br />a <br />C1 <br />W c.i'.� <br />Ora <br />'_j W <br />Q <br />�U — <br />O W <br />C <br />.12 <br />E <br />o 0 <br />FM <br />U <br />4 c', <br />W <br />1—c� <br />M <br />c W rM <br />OoN <br />U <br />LL <br />0 0 <br />ao <br />Q cm <br />A __L <br />D. <br />'I* <br />-*§ <br />N <br />in N <br />a, a N <br />Z 0 ifl <br />Z <br />z o <br />j <br />Z W „Mrn <br />/y � N wg G <br />IiY <br />� z <br />(n <br />- ONCD LLL 11 <br />W S <br />LL, <br />O 5 <br />d <br />6 z <br />Z O tJ (n <br />m <br />W <br />Z EI2 <br />mZ <br />�g <br />aN <br />J�W <br />2E O <br />U <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z fV <br />0 <br />M 0 <br />I/ -'I U) <br />Z <br />41 <br />Q O L0 <br />0 N <br />Q �LL� <br />Z <br />M <br />Q�UCL 0 <br />Q <br />Z E <br />Z <br />W <br />J <br />d' <br />cc <br />LU <br />Za <br />fa <br />yaa <br />Q <br />�ZOOU <br />a— <br />Z w Z <br />Q)a�Z <br />a Oro <br />�0o <br />g'o <br />V <br />T <br />� <br />go <br />O <br />J <br />W <br />�Z <br />Z <br />03 <br />Imo\ <br />W <br />g <br />o <br />U <br />r <br />^' <br />O <br />U.)\ <br />v^' <br />�j <br />O <br />J <br />U_ <br />o�z <br /><�P <br />0 � <br />J <br />0 <br />Moe <br />N <br />S <br />Zw¢ <br />1<3< <br />Z <br />N <br />LL� <br />a�o <br />u_ <br />aQ'W'.7 <br />LU <br />Ln Ln <br />LLJ <br />6i <br />Z <br />0 <br />� H <br />w�F <br />u�. Z <br />I <br />Z�f) <br />t <br />Rz <br />0 <br />p <br />06 <br />Z <br />g <br />= <br />a w <br />Z <br />rn <br />.--1 <br />a- <br />Ul) <br />SCALE : AS NOTED <br />DATE : 1 /5/2018 <br />TECH: M]AMES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.