Laserfiche WebLink
a <br />e <br />SEE SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN REFER TO PLANS <br />_ - FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />- LATH OVER BARRICADE PLUS WRB <br />- = (OR APPROVED EQUAL) <br />- BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />UN <br />�Y(REFER TO ELEV.) <br />INSULATION AS <br />2X ALUM WRAPPED FASCIA <br />PER SPECS. <br />----- <br />BD. WALUM DRIP EDGE <br />PRE-ENGINEERED <br />SOFFIT INSTALLED PER <br />GABLE END ROOF <br />MANUF. SPECS <br />TRUSS - REFER TO <br />2X PT BLOCKING <br />STRUCTURALS <br />HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. <br />MASONRY LINTEL - REFER TO <br />STRUCTURALS <br />TYP. HIPPED PENT ROOF DETAIL <br />SCALE: 1/2" = V-0" 1-STORY - MASONRY WALL <br />S•T•1;��:u.r��•PL <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />12 <br />R905.1.1.1 (SEE SHEET CS2) 12 <br />SEE ROOF <br />PRE-ENGINEERED ROOF SEE ROOF <br />PLAN <br />TRUSSES AT TYP. 24" O.C. PLAN <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OIL TOP OF C.M.U. <br />'IF(REFER TO ELEV.) <br />INSULATION PER ! <br />COMMUNITY SPEC. I <br />2x6 ALUM WRAPPED FASCIA <br />EE <br />SEE ENERGY CALCS. _. _.. <br />BD. w/ALUM DRIP EDGE <br />1/2" (MIN.) CLG. BD. ----J 1/2" (MIN.) J <br />SOFFIT INSTALLED PER CLG. BD. <br />1x PT DRAPE BLKG MANUF. SPECS (J" TYPE'X' GYP. BD. <br />ABOVE WINDOWS 1/2" 2X PT BLOCKING TO BE PROVIDED <br />G.W.B. WHEN LIVING SPACE <br />SEE STRUCTURAL IS ABOVE GARAGE) <br />WINDOW PER PLAN / III I PLAN <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT PRECAST WIN. SILL <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @ 24" O.C. SLOPE GRADE AWAY <br />BASE BOARD FROM HOUSE GARAGE SLAB, <br />SEE STRUCTURAL 4 <br />0'-0" PLANS <br />FIN. FL. SLOPE <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL WINDOW <br />SCALE: 1/2" = V-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4 <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />J" GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GRADE <br />_. <br />BOARD <br />all <br />ELECTRICAL <br />PANEL <br />I!co <br />EllCOETE <br />NCR <br />. B REFER <br />TO PLANS <br />v <br />GYPSUM — <br />BOARD <br />J" GYPSUM <br />BOARD <br />NICHE FOR <br />ELECTRICA <br />PANEL & <br />WIRING <br />ELECTRIC <br />PANEL <br />EXTERIOR- <br />CMU BLOCI <br />WALL <br />CONCRETE <br />CURB REFS <br />TO PLANS <br />DONCRETE- <br />SLAB ON <br />GRADE AT <br />GARAGE <br />FLOOR <br />o <br />v <br />M <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />06 TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. WALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />DRIVEWAY PER COMMUNITY <br />SPECS <br />0'-0" <br />SLOPE FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />WALL SECTION @) GARAGE DOOR <br />SCALE: 1/2" = V-0" <br />ATTIC <br />FLOOR <br />REFER <br />OR SECOND <br />LIVING SPACE <br />TO PLANS <br />• <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = V-0" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />cc <br />W <br />WZO= <br />O �- F- <br />> cr a 0 <br />W Z) 0 F- <br />U) 0 W W <br />Q = W F- <br />(n <br />J W W <br />cc cc cr <br />YQF-Z <br />,du-00C/) <br />ZZZI- <br />Z <br />cc. 15 < <br />w 0- CL <br />�cnp0U <br />= Z U- U) <br />�F-Qz0 <br />cz <br />CZ � C <br />O Zd� <br />a o <br />H <br />0 <br />O <br />Q <br />O <br />w <br />a <br />w <br />x <br />cn <br />O <br />R <br />U) <br />W <br />z <br />Z <br />Od <br />U <br />�Z <br />G <br />aaaaa <br />JAN 2 0 2022 <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 1/19/22 <br />SHEET <br />A5•2 <br />