r <br />0 <br />Termite Specifications: <br />Structural <br />Notes: <br />Structural Design Criteria: <br />General Notes: <br />FOUNDATIONS <br />CODES: FLORIDA BUILDING CODE, 2001 EDITION <br />�;, <br />w 41 <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />PREFABRICATED WOOD TRUSSES <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />THE FOLLOWING TECHINCAL CODES <br />°'r�`'°.' <br />N, • <br />.±'` <br />O� <br />N w o. <br />AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-89) <br />SHALL APPLY: <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ASTM - 1557 ( MODIFIED PROCTOR) <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />8 z to <br />ELECTRIC PANEL.(FBC 104.2.6) <br />FOUNDATION INSPECTIONS <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />2O01 FLORIDA BUILDING CODE, <br />C3 <br />Lj <br />w 9 <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST V-0" <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED INcc <br />APA PLYWOOD DESIGN SPECIFICATION <br />PLUMBING MECHANICAL FUEL GAS <br />a <br />ig <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />Z <br />g o <br />_ <br />a w 3 <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />DESIGN SPECIFICATION FOR STRESS -GRADE LUMBER AND <br />LIVE LOADS: ROOF <br />AND 2002 NATIONAL ELECTRICAL CODES <br />Of <br />ao <br />a a0 1 <br />z <br />8 o z <br />EXPOSED AND A STRING STRECHED FROM MARKER TO <br />TOP CHORD 20 PSF <br />Ld <br />, <br />co o rn <br />_ e, <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />BOTTOM CHORD (W/O STORAGE) 10 PSF <br />ORDINANCE 92-19 - APPENDIX"? <br />Lv <br />Z <br />"� t° <br />r rn rn N <br />z <br />~ w 00 P <br />Td <br />SHALL NOT BE INSTALLED WITHIN V-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br />CAST IN PLACE CONCRETE <br />FOREST PRODUCTS ASSOCIATION. <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED 40 PSF <br />TO FBC PLUMBING 2001 CODE. <br />C7 <br />X ri..a0 <br />om E!� n • <br />� m � � z <br />w > O <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION BETWEEN WALL <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 6" <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />BALCONIES 40 PSF <br />STAIRS 40 PSF <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />z <br />Lv <br />-:° - m <br />p co <br />'• ,, <br />°' <br />o s 0 <br />z N z z <br />t z y <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br />0 <br />FOR LOAD DURATION OF 25 /o) TO WITHSTAND THE LIVE <br />J <br />o <br />c x <br />o E N c <br />7d <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />DEAD LOADS: ROOF 17 PSF (SHINGLE) <br />FLOOR 15 PSF <br />2. WALL MOUNT WATER CLOSET VOLUME <br />3.5 GALLONS <br />Q <br />[r <br />c <br />r w <br />a <br />_ <br />8 0 <br />N <br />_ <br />W E C B <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />iE <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />3. WATER - FLOW RATE. <br />W <br />H <br />= c �`' o w <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />NOTED ON THE PLANS. <br />WIND LOADS: WIND LOADS BASED ON FBC, SECTION 1606.2. <br />PUBLIC FACILITIES 0.5 G.P.M. <br />Z <br />_ y o <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />GRADE 40. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />(F.B.C.) WIND VELOCITY: 123 M.P.H., USE FACTOR: 1.0 <br />PRIVATE FACILITIES 2.2 G.P.M. <br />IS COMPLETE.(FBC 1816.1.1) <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />CONCRETE ALL CONCRETE UNLESS OTHERWISE INDICATED 2500 PSI <br />SHOWER HEADS 2.5 G.P.M. <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE DESIGN <br />STRENGTH PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY 3000 PSI <br />4. ALL PLUMBING WATER LINES <br />TO BE PVPC <br />INCLUDING SPACES BOXED AND FORMED.(FBC 1816.1.2) <br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />LOADS AS LISTED ON THE STRUCTURAL DESIGN CRITERIA <br />@ 28 DAYS (DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br />ALL TOP BARS OF BEAMS. <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />VTR LOCATIONS ARE APPROXIMATE <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT V-0" <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />REINFORCING: WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 <br />AND MAY CHANGE DUE TO JOBSITE <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />PLATE INSTITUTE TPI LATEST EDITION. <br />ALL REINFORCING BARS ASTM A615-40 40,000 PSI <br />CONDITIONS <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br />LAP PROVIDED <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />ALL STIRRUPS AND TIES ASTM A615-40 40,000 PSI <br />THE FOLLOWING SHALL COMPLY <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />CONCRETE ASTM C90 OR C129, STANDARD WEIGHT UNITS, fm=1500 PSI <br />WITH THE 2001 FBC. <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />7. CONCRETE COVER MIN. 3 WHEN EXPOSED TO EARTH OR <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />MASONRY MORTAR TYPE "S" 1900 PSI <br />UNITS: CONCRETE GROUT 3000 PSI <br />® PORCHES AND BALCONIES <br />REQUIRED.(FBC 1816.1.4) <br />1 1/2" TO FORM <br />SECTION 1014 <br />MASONRY WALL CONST. <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br />❑ HANDRAILS - SECTION 1007.5 <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />STRUCTURAL ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />❑ GUARDRAILS - SECTION 1015, 1019.9 <br />0 <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />STEEL: SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br />❑ STAIRS - SECTION 1007 <br />Ic v <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI (Pm = 1500 PSI) <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />❑ CHIMNEY &FIREPLACE <br />( <br />0 F, cr, a� <br />WITHIN V-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br />2. MORTAR SHALL BE TYPE "M" OR "S", CONFORMING TO <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />WOOD FRAMING: BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O. <br />SSECTION ECTION 2803-2806 (MAR) <br />� o w N 'm <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />ASTM C270. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES ALL <br />NO. 2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D EXTERIOR or OSB <br />® EGRESS WINDOWS <br />�+ � 1 a1 <br />(Un � 0 W <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br />FLOOR SHEATHING: 3/4" PLYWOOD (5 PLIES) OR 3/4" T&G ADVANTECH <br />SECTION 1005.4 <br />+, +. 41 � � y en <br />n n � C5 <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />4. ALL OPENINGS SHALL COMPLY WITH <br />VERSA LAM BEAM Fb = 2900 PSI (2.OE) <br />({ a� 3 <br />01 <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT.(FBC 1816.1.7) <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />2001 FBC WIND LOADS AS STATED <br />U cv U) U '� w 3 <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />WOOD ROOF DESIGN LOADS: <br />BELOW. ATTACHMENTS OF WINDOWS, <br />13. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />UPLIFT CONNECTORS <br />TRUSSES: TOP CHORD LIVE AND DEAD LOAD; 27 PSF <br />DOORS, SLIDING GLASS DOORS <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />BOTTOM CHORD LIVE AND DEAD LOAD: 20 PSF <br />AND O.H. GARAGE DOORS ARE TO DELEGATED <br />-zz <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: 'THE BUILDING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS TRUSS <br />TOTAL: 47 PSF <br />THE MANUFACTURER OF THESE ITEMS. THE <br />o <br />'�' <br />z f <br />o g W O <br />0 S <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MANUFACTURER OF THESE ITEMS <br />W <br />W O W <br />w v� ¢ <br />a 9 z w Z -U z F- <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />OTHERWISE NOTED. <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />NET UPLIFT DESIGN PRESSURE: 20 PSF WITHIN <br />SHALL SUBMIT ATTACHMENTS FOR <br />< Q � <br />Q F- <br />o' � = z u. z z 0 ¢ S a <br />a cn 0 0 �-• w� w 0 a <br />FLORIDA DEPARMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816.1.7) <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />4 FEET OF RIDGES, HIPS, EAVES AND BUILDING <br />MIN <br />SITE INSTALLATION. <br />H <br />O' <br />Z <br />w a <br />o w o Q z g v ¢ <br />~ ~ ¢ a <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />PERIMETER AND 15 PSF FOR ALL OTHER AREAS. <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />O <br />LL <br />¢ a -' 0 <br />¢ �- w (n ►-� w w w <br />HO <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />7. DUR-0-WALL SHALL BE PROVIDED @ EVERY OTHER <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />MANUFACTURERS DESIGN CRITERIA AND <br />O LU Q F- w Q 2 O <br />Q ¢ O 0 H z <br />� <br />BELOW AND WITHIN 1' 0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />COARSE OR 16" O/C <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />INSTALLATION METHODS FOR WINDOWS, <br />o <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />WOOD CONSTRUCTION <br />A MAXIMUM OF 10 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />(FBC 2303.1.3) <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />DEAD LOAD. <br />GARAGE DOORS, AND ROOFING. <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />CONSTRUCTION", 2001 EDITION. <br />WOOD FLOOR DESIGN LOADS: <br />WITHIN 15'-0"; OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />FIELD REPAIR NOTES <br />TRUSSES: DEAD LOAD: 15 PSF <br />5. ALL DOORS INTERIOR &EXTERIOR ARE <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, <br />LIVE LOAD: 40 PSF <br />6'-8" UNLESS OTHERWISE NOTED <br />� <br />( I.E. BLOCKING OR GABLE END BRACING SHALL BE EITHER <br />1. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY <br />TOTAL: 55 PSF <br />ALL SHOWER ENCLOSURES TO BE <br />0 <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />BE SUBSTITUTED W/ (1) "SIMPSON MTSM16 TWIST STRAP W/ <br />TEMPERED GLASS <br />USED REGARDLESS OF SPECIES. <br />3. ANY WOOD FRAME BEARING WALL STUDS THAT ARE CUT <br />(4) 1/4" X 2 1/4" DIA. TITENS TO THE BOND BEAM BLOCK <br />AND (7) 10d TO THE TRUSS FOR UPLIFTS OF 1000 LBS. OR <br />SOIL BEARING ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />6. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR &EXTERIOR) AND WITHIN <br />Z <br />O <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH <br />2 <br />LESS. USE (2) FOR 000 LBS. OR LESS. OTHERS MAY BE <br />VALUE: SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />18" OF FLR TO BE TEMPERED GLASS. <br />1--1 <br />SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br />SUBSTITUTED ON A CASE BY CASE BASIS. <br />SHALL CONTACT <br />(SECTION 2405.2) <br />V) <br />F-1 C) Ln <br />4. ALL STUCCO FINISH OVER EXTERIOR FRAME MUST BE 7/8" THICK <br />2. MISSED "T BOLTS FOR WOOD BEARING WALLS MAY BE SUB- <br />THE GENERAL CONTRACTOR THE ENGINEER PRIOR TO <br />OF <br />CO k <br />PER ASTM C. 926-APPLY 3 LAYERS WITH TOTAL THICKNESS 7/8" <br />STITUTED W/ 1/2" DIA. ANCHOR BOLTS SET IN 3/4" DIA. X 6" <br />FOUNDATION POUR FOR VERIFICATION FOUNDATION DESIGN. <br />1-1 M <br />OVER METAL LATH. <br />DEEP UNITEX "PROPDXY" 300 ADHESIVE BINDER FOLLOWING <br />N ko <br />L M <br />FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8 THICK. <br />ALL MANUFACTURERS RECOMMENDATIONS (OR 1/2" X 6" <br />RAWL STUD EXPANSION ANCHORS.) <br />< 0 <br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH <br />3. REGARDING MISSED REBAR IN VERTICAL FILLED CELLS: <br />CLaC Vi t--� <br />EARTH OR CONCRETE TO BE PRESSURE TREATED. <br />DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF <br />G Q 00 <br />*ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS <br />THE OMITTED REBAR, AND INSTALL A 32" LONG #5 BAR INTO <br />r� <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE <br />THE EPDXY FILLED HOLE. USE A TWO PART EMBEDDEMENT <br />"EPDXY " <br />(CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR <br />GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED <br />EPDXY ( SIMPSON TIE SET', OR HILTI 2 PART' <br />EMBEDDMENT EPDXY), MIXED PER MANUFACTURER'S <br />Building Data: <br />Index Of Drawings <br />z <br />WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. <br />INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM <br />MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS <br />DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND <br />SHT NO: <br />TLE <br />THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S <br />AND USING COMPRESSED AIR PRIOR TO APPLYING THE EPDXY. <br />CONSTRUCTION TYPE -- TYPE VI UNPROTECTED <br />WIND SPEED 123 MPH <br />O <br />A <br />COVER SHEET <br />RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO ALLOW THE EPDXY TO CURE TO MANUFACTURER'S SPECIFICATIONS, <br />(SECTION 608 - FBC 2001) <br />WIND IMPORTANCE FACTOR -- (Iw) = 1.0 <br />SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. <br />THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM <br />WIND EXPOSURE -- "B" (FBC 1606.1.8) <br />Al <br />FLOOR PLAN <br />FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT -DIPPED POUR. <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.55 (PART. ENCLOSED) <br />GALVANIZED OR STAINLESS STEEL FASTENERS. <br />4. HURRICANE STRAPS MAY BE SUBSTITUTED WITH A STRAP OF <br />A2 <br />FOUNDATION PLAN <br />DOT SODIUM BORATE (SBX) DOES NOT. <br />GREATER HOLDOWN VALUE OR GREATER UPLIFT VALUE IN THE <br />A3 <br />ELECTRICAL PLAN <br />FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURERS <br />WIND BORNE DEBRIS AREAS <br />DESIGN WIND PRESSURE: <br />WOOD FRAMING INSPECTION <br />INSTALLATION INSTRUCTIONS ARE FOLLOWED. <br />COMPONENT AND CLADDING) WORST CASE (10 SF -END ZONE) <br />(IN <br />A4.1 <br />ELEVATION I <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />5. FOR MORTAR JOINTS LESS THAN <br />OF PROVIDE (1) <br />IN CONC. FILLED CELL EACH SIDE OF THE JOINT (BARR DOES DOES <br />THE METHOD TO SATISFY PROTECTION OF OPENINGS <br /># END ZONE IS ONLY WITHIN T-0" <br />A4.2 <br />ELEVATION II <br />ROUGH -INS MUST BE COMPLETE, INSPECTED <br />NOT HAVE TO BE CONT. TO FOOTING) <br />THESE AREAS WILL BE THE SOLE RESPONSIBILITY <br />OF ALL EXTERIOR BUILDING CORNERS <br />A4.3 <br />ELEVATION III <br />AND APPROVED BEFORE REQUESTING FRAMING <br />OF THE CONTRACTOR. <br />INSPECTION. <br />WINDOWS AND DOORS <br />A5.1 <br />ROOF FRAMING ELEV I <br />THEIR OPTIONS ARE AS FOLLOWS: <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br />A5.2 <br />ROOF FRAMING ELEV II <br />A. IMPACT RESISTANT GLAZING <br />A5.3 <br />ROOF FRAMING ELEV III <br />B. APPROVED SHUTTERS <br />A6 <br />INTERIOR ELEVATIONS <br />C. SUPPLY WOOD STRUCTURAL PANELS <br />cn <br />PER FBC 1606.1.4 <br />S-1 <br />FOUNDATION DETAILS <br />o <br />S-2 <br />LINTEL DETAILS <br />S-2A <br />LINTEL PLANS <br />O <br />S-3 <br />ROOF FRAMING (I, II, III) <br />O <br />S-4 <br />BRACING DETAILS <br />C/) <br />> <br />Master Revisions: <br />WALL SECTIONS <br />N <br />=_ <br />ALL WORK SHALL COMPLY WITH ALL <br />S-6 <br />STRUCTURAL NOTES & <br />HANGER INFORMATION <br />_ <br />} <br />PREVAILING CODES, FLORIDA BUILDII �� <br />' <br />a W <br />0 <br />DATE <br />DESCRIPTION <br />CODE, NATIONAL ELECTRIC CODE AND <br />S-8 <br />WINDOW &DOOR DETAILS <br />W <br />z z <br />o <br />jT LS ORDINANCES <br />CT OF ZEPHYRHIL <br />S-9 <br />WINDOW & DOOR DETAILS <br />. _ <br />O <br />U <br />1--1 <br />w O <br />U Z <br />S-10 <br />WINDOW & DOOR DETAILS <br />> <br />ED <br />RF-VIE <br />ENGINEERED PLANS <br />S-11 <br />S-12 <br />WINDOW & DOOR DETAILS <br />PRODUCT APPROVAL INFO <br />co <br />_ <br />N <br />L <br />z <br />a <br />MAY 0 9 2005 <br />ON FILE <br />U <br />> E <br />= <br />"ztso <br />w w <br />m = <br />~W <br />_ <br />C: <br />' s <br />�/ <br />UU <br />Z L <br />g w °� <br />Z <br />N Builder oti ce T o <br />C:)a <br />z <br />=X <br />CENTRAL <br />FLORIDA DIVISION, <br />600 N. WESTSHORE BLVD. SUITE 600 <br />o <br />0- <br />F_ <br />IT IS THE INTENT OF THIS DESIGNER THAT <br />TAM PA FLORIDA <br />33609 <br />(813) 769-5277 <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />V <br />SHEET <br />NO. <br />ONAL TO CONSTRUCT THIS PROJECT. <br />IN THE EVENT THAT SOMETHING IS UNCLEAR <br />OR NEEDS CLARIFICATION..STOP..AND CALL <br />o <br />coW <br />A <br />UU <br />u1i <br />O <br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT <br />w <br />= <br />IS THE RESPONSIBILITY OF THE LICENSED <br />, /� <br />M <br />ANDOVER <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />V ♦ <br />O <br />LAST PLOT DATE <br />Mar. 23, 05 <br />In <br />c <br />O <br />.2.005 <br />BEFORE ANY WORK IS DONE. <br />J <br />COVER SHEET <br />N <br />1 <br />4 <br />