My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7795 Davie Ray Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7795 Davie Ray Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:05:43 AM
Creation date
2/27/2025 11:29:14 AM
Metadata
Fields
Template:
Building Plans
Street #
7795
Location
Davie Ray Dr
Contractor
DR Horton
Building Plans - Permit #
386
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />f" <br />r-. <br />• STATE OF <br />CERTIFIED <br />FLORIDA DESIGN CRITERIA: <br />BUILDING CONTRACTOR: • FLORIDA BUILDING CODE, RESIDENTIAL, <br />6TH EDITION (2017) <br />• AIL LOCAL AND STATE CODES <br />DR HORTON HOMES <br />12602 TELECOM DRIVE <br />TAMPA, FL 33637 <br />TEL: (813) 740-9720 <br />FAX: (813) 740-9715 <br />• STATE OF FLORIDA <br />PROFESSIONAL ARCHITECT: <br />ROLAND A. ABOUCHACRA <br />AR No. 93723 <br />A.B. DESIGN GROUP, LLC. <br />1441 NORTH RONALD REAGAN BLVD. <br />LONGWOOD, FLORIDA 32750 <br />Tel: (407) 774-6078 <br />Fax: (407) 774-4078 <br />DRAWING / CONTRACT DOCUMENT <br />REVIEW BY BUILDER <br />THE BUILDER ASSUMES ALL LIABILITY FOR <br />INTERPRETATION OF THE CONTRACT DOCUMENTS. <br />IF ANY ASPECT OF THE CONSTRUCTION (AS <br />DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND <br />IN NEED OF FURTHER DETAILING OR EXPLANATION IN <br />ORDER TO BUILD THIS PROJECT BASED ON THIS <br />DRAWING SET, THE CORRECT PROCEDURE IS FOR THE <br />BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR <br />INFORMATION) TO THE ARCHITECT OR ENGINEER FOR <br />CLARIFICATION. <br />AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN <br />RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY <br />MANNER. AB DESIGN GROUP TAKES NO <br />RESPONSIBILITY FOR INTERPRETATIONS OF <br />CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE <br />BEEN GENERATED FOR UNCLEAR ASPECTS OF THE <br />CONSTRUCTION BASED ON THE DRAWING SET. <br />*OCCUPANCY <br />• CONSTRUCTION TYPE <br />• MIN. INTERIOR FINISH <br />• BASIC WIND SPEED <br />•EXPOSURE <br />*I —STORY RESIDENCE <br />• 2—STORY RESIDENCE <br />— RESIDENTIAL, GROUP R3 <br />— VB <br />— CLASS B <br />— Vult=160 MPH <br />Vasd=124 MPH <br />—C <br />— MAX. HEIGHT AS PER LOCAL <br />AND STATE CODES <br />SQ.FT. <br />IST FLR LIVING <br />2ND FLR LIVING <br />CALL .' S <br />1046 SQ. FT. <br />139g SQ. FT. <br />TOTAL LIVING <br />2441 <br />SQ. FT. <br />GARAGE <br />403 <br />SQ. FT. <br />ENTRY <br />32 <br />SQ. FT. <br />TOTAL <br />2882 <br />SQ. FT. <br />8X10 PATIO <br />80 <br />SQ. FT. <br />12602 TELECOM DRIVE, TAMPA, FL. 33637 <br />Tel: (813) 740-9720 <br />Fax: (813) 740-9715 <br />ABBREVIATIONS <br />REVISIONS <br />ABV. <br />ABOVE <br />LAV. <br />LAVATORY <br />DATE <br />DESCRIPTION <br />08/08/11 <br />2-STORY BLOCK CONVERSION <br />A/C <br />ADJ. <br />AIR CONDITIONING <br />ADJUSTABLE <br />LUM. <br />M.C. <br />LUMINOUS <br />MEDICINE CABINET <br />01/16/18 <br />BID SET ISSUED <br />ALT. <br />AMP. <br />ALTERNATE <br />AMPERAGE <br />MFR. <br />MIN. <br />MANUFACTURER <br />MINIMUM <br />01/22/IS <br />2011 FBC UPDATE <br />BD. BOARD M.T. METAL THRESHOLD <br />CL <br />CAB. <br />CENTER LINE <br />CABINET <br />MTD. <br />MTL. <br />MOUNTED <br />METAL <br />02/12/16 <br />STONE ELEVATIONS ADDED <br />CLG, <br />CLR. <br />CEILING <br />CLEAR <br />N.T.S. <br />O.C. <br />NOT TO SCALE <br />ON CENTER <br />02115AO <br />I 51D SET RE -ISSUED <br />04/16/I8 <br />FOOTING REVISION PER M. BOUIES <br />CONC. <br />CPT. <br />CONCRETE <br />CARPET <br />PL <br />P.B. <br />PROPERTY LINE <br />PUSH BUTTON <br />05/14/I6 <br />INCORPORATE I -JOIST DETAILS t FRAMING PLANS PER M. 50WES <br />C.T. CERAMIC TILE PH, PHONE <br />D. <br />DRYER <br />PLT. <br />PLATE <br />01/12/18 <br />CONSTRUCTION DOCUMENTS RE -ISSUED <br />DBL. DOUBLE PLYWD. PLYWOOD <br />D.G. <br />DIA. <br />DUAL GLAZED <br />DIAMETER <br />PR. <br />P.T. <br />PAIR <br />PRESSURE TREATED <br />08/20/18 <br />50LLARD DETAIL REVISED <br />DIM. <br />DISP. <br />DIMENSION <br />DISPOSAL <br />R. <br />RAD. <br />RISER <br />RADIUS01/26/15 <br />DETAIL- 'ADDING BAR TO BOND BEAM" ADDED TO SI2A <br />02/15AS <br />TRUSS ID'S ADDED TO FRAMING SHEET <br />DP. <br />DR. <br />DEEP <br />DOOR <br />R.A.. <br />REF• <br />RETURN AIR <br />REFRIGERATOR GRILL <br />02/26/1S <br />PLAN MAINTENANCE <br />D.S. <br />DTL. <br />DOWNSPOUT <br />DETAIL <br />RM. <br />R.O. <br />ROOM <br />ROUGH OPENING <br />D.W. <br />DISHWASHER <br />S.C. <br />SOLID CORE EXT DR <br />04/01/1S <br />REVISED LINTEL SIZE Q ENTRY <br />EA. <br />ELEV. <br />EACH <br />ELEVATION <br />S.D. <br />S.H. <br />SMOKE DETECTOR <br />SINGLE HUNG <br />04/26/115 <br />UPDATED LEDGER BOLT SIZE t SPACING <br />EQ. <br />EXH. <br />EQUAL <br />EXHAUST <br />SHT. <br />SHTHG. <br />SHEET <br />SHEATHING <br />06/21/19 <br />ADDED LED LIGHTS * KITCHEN t BATHROOMS PER MARK 501JUES <br />08/21AS <br />REVISED I -JOIST LAYOUT <br />EXT. <br />F.G./FX . <br />EXTERIOR <br />FIXED GLASS <br />SHWR. <br />SIM. <br />SHOWER <br />SIMILAR <br />09/13/IS <br />LEDGER BOLT SPACING REVISED <br />F.G. <br />FIN. <br />FUEL GAS <br />FINISH <br />SL. <br />SL. GL. <br />SLIDING <br />SLIDING GLASS <br />01/01/20 <br />REPLACE USP CONNECTORS WITH SIMPSON CONNECTORS <br />FLR. FLOOR STD. STANDARD <br />FLUOR. <br />FR. DR. <br />FLUORESCENT <br />FRENCH DOOR <br />SWS <br />SHEAR WALL <br />SECTION <br />05/01/20 <br />REVISED STAIRCASE AND STAIR SECTION DETAIL <br />FTG. <br />FOOTING <br />TEMP. <br />TEMPERED GLASS <br />GA. <br />GAUGE <br />THK. <br />THICK <br />GAR. DISP. GARBAGE DISPOSAL T.O.C. TOP OF CURB <br />G.F.I. <br />GROUND —FAULT CIRCUIT <br />T.O.P. <br />TOP OF PLATE <br />INTERRUPTER T.O.S. TOP OF SLAB <br />GL. <br />GLASS <br />TYP. <br />TYPICAL <br />GYP. BD. <br />GYPSUM BOARD <br />U.N.O. <br />UNLESS NOTED <br />H.B. <br />HOSE BIB <br />OTHERWISE <br />H.C. <br />HOLLOW CORE <br />V.P. <br />VAPOR PROOF <br />HDR. <br />HEADER <br />W. <br />WASHER <br />HGT. OR HT <br />HEIGHT <br />W/ <br />WITH <br />INSUL. INSULATION WD. WOOD <br />INT. <br />INTERIOR <br />WDW. <br />WINDOW <br />W/H WATER HEATER <br />W.I. <br />WROUGHT IRON <br />CODES .el.. 1 ?s� trx. �,7 E. <br />NATiC N <br />AND T►'1 s ,`Ra1LL <br />ORDINANCE <br />Cr 1 n -, I — <br />INDEX CF DRAWINGS <br />ARCHITECTURAL SKIT . ET <br />PG CS -COVER PAGE <br />PG GN- GENERAL NOTES <br />PG Al -FIRST FLOOR PLAN <br />PG A1A-DETAILS <br />PG A2-SECOND FLOOR PLAN <br />PG A3G-FRONT & REAR ELEVATION "G" <br />PG A4G-LEFT & RIGHT ELEVATION "G" <br />PG El -FIRST FLOOR ELECTRICAL PLAN <br />PG E2-SECOND FLOOR ELECTRICAL PLAN <br />PG P1-PLUMBING PLAN <br />PG M1-FIRST FLOOR MECHANICAL PLAN <br />PG M2-SECOND FLOOR MECHANICAL PLAN <br />PG D1-DETAILS <br />PG D2-DETAILS <br />PG D3-DETAILS <br />PG D4-PRODUCT APPROVAL <br />PG WA1-WALL ASSEMBLY DETAILS <br />PG WA2-WALL ASSEMBLY DETAILS <br />PG WA3-WALL ASSEMBLY DETAILS <br />PG WA4-WALL ASSEMBLY DETAILS <br />PG WA5-NOT USED <br />PG WA6-WALL ASSEMBLY DETAILS <br />STRUCTURAL SHEET # <br />PG S1—FOUNDATION PLAN <br />PG S1.1A—DETAILS <br />PG S1.1B—DETAILS <br />PG S1.2—FIRST FLOOR DOWEL PLAN <br />PG S1.2A—DETAILS <br />PG S2—FIRST FLOOR LIFT BEAM PLAN AND NOTES <br />PG S2.1A—DETAILS <br />PG S3—FIRST FLOOR FRAMING PLAN <br />PG S3.1A—DETAILS <br />PG S3.1B—DETAILS <br />PG S4—SECOND FLOOR DECK PLAN <br />PG S4.1A—DETAILS <br />PG S4.2—SECOND FLOOR DOWEL PLAN <br />PG S5—SECOND FLOOR LIFT BEAM PLAN AND NOTES <br />PG S6-ROOF FRAMING PLAN <br />PG S6.1A—DETAILS <br />PG SN1—DETAILS <br />DESCRIPTION <br />DESCRIPTION <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />F <br />w <br />� <br />J <br />w <br />% <br />Lu <br />O <br />Lu <br />Lu <br />O <br />J <br />Ll <br />C�.1 <br />LU <br />W <br />W <br />cn <br />c <br />QEQ <br />4 <br />Q <br />0 <br />0 <br />ti <br />co <br />ISUBDIV. &LOT: <br />ABBOTT <br />PARK <br />LOT #38 <br />BLK 9 <br />PROJECT# <br />04181.000- 38091 <br />MODEL: <br />3EFB <br />2447- ROBIE" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />COVER <br />SHEET <br />60 MPH EXP. C <br />PRINT 05 26 20 <br />DATE: <br />SCALE: <br />SHEET <br />c s <br />
The URL can be used to link to this page
Your browser does not support the video tag.