Laserfiche WebLink
NOTE: <br />APPROVED BUILDING WRAP 6 u <br />SHALL BE LAPPED A MINIMUM OF 4'x4' SELF -ADHERING MEMBRANE <br />6VERTICAL LAPS (ROLL FLASHING (COMPATIBLE W/ HOUSE �a <br />ENDS) 4 W * HORIZONTAL LAPS. WRAP MATERIAL) OVER <br />LATH VERTICAL LAP TO BE I' APPROVED HOUSE WRAP.'' <br />ALL SEAMS NEED TO HI: GAPED FLASHING TO EXTEND ONTO PIPE <br />WITH FORTIBER SHEATHING TAPE �....................,;;........... <br />/ I' OR LESS PIPE `:' 4' <br />6 xb SELF -ADHERING MEMBRANE <br />PREFORMED CONTROL JOINT i �' THICK, 3 COAT CEMENT PENETRATION FLASHING (COMPATIBLE W/ HOUSE <br />\ l <br />WRAP MATERIAL) OVER 41x4' <br />PLASTER <br />FLANGE OF CONTROL JOINTS T / \:: ;.:.: ,:,:, SELF -ADHERING MEMBRANE <br />BE WIRED TIED t0 LATH 0 9' � WRB LAYER 02, FORTIFIBER '' <br />FLASHING OVER APPROVED <br />> : HOUSE WRAP. <br />O.C. MAX (VERT.). NOTE: DO BUILDING PAPER 1' MIN. LAP METAL LATH NOT FASTEN CONTROL JOINT TO FLASHING t0 EXTEND ONTO PIPE <br />/ \ <br />WALL EVEN IF STUD EXISTS <br />BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH <br />3/a' LEG MAY BE USED t0 TEMP. FASTENED *�' (VERT.) O.G. MAX X X X <br />SECURE CONTROL JOINT AT SUPPORTS X X X — <br />DURING INSTALLATION CUT AND OVERLAP ONE SIDE OF <br />WRB LAYER 01, r— SELF -ADHERING MEMBRANE <br />METAL LATH CUT AND OVERLAP ONE SIDE OF <br />� O.G. MAX VERTICALLY <br />FASTENERS TO BE SPACED STUCCO WRAP ( FLASHING SELF -ADHERING MEMBRANE <br />* WOOD SHEATHING <br />WRB LAYER "I, �' THICK, 3 COAT CEMENT CJ� STEP *2 FLASHING <br />STUCCO WRAP I PLASTER STUCCO Y�P <br />r• <br />METAL ATH <br />6' MIN PAPER LAP BELOW ONL <br />WRB LAYER 02 FORTIFI le <br />BERY TIF15ER AY �'2 FOR WRB LAYER <br />BUIL ING PAPER <br />R <br />\ WRB LAYER 02, FORTIFIBER, I BUILDING PAPER <br />BUILDING PAPER METAL LATH <br />STUCCOWRAP6'x6' SELF -ADHERING MEMBRANE <br />FLASHING OVER 4'x4' <br />SELF -ADHERING MEMBRANE <br />TO I INSTALL FASTENERS (CLIPS, FLASHING OVER APPROVED <br />LATH SHALL NOT GAP MIN. WOOD SHEATHING HOUSE WRAP. <br />BE CONTINUOUS 6' TO s' 6' TO a' IRE D O SECURE <br />FLASHING TO EXTEND ONTO PIPE <br />THROUGH CONTROL <br />MIN. MIN. PIPE/ WIRE TO FRAMING <br />• �� ., � 4'x4' SELF -ADHERING MEMBRANE <br />JOINTS BUT SHALL \ ,, .. -...: . u''V x'.i k,swhtr ash _, I. n s ,c <br />FLASHING OVER APPROVED <br />BE STOPPED AND HOUSE WRAP. <br />TIED AT EACH SIDE. —PROVIDE 2X4 BLOCKING I' MIN LATH FLASHING TO EXTEND ONTO PIPE <br />PER ASTM C1063 LAP, 4' OVER <br />i 1014 PLACED FLAT MAX. 6' TO 8' ALL LAP <br />FROM CONTROL JOINT WHEN <br />CONTROL JOINT FALLS ON AP E R LAP %8 CONT. BEAD OF SEALANT <br />NOTE:SCALE: I I/Z' ■ I'-0' <br />STRUCTURAL STUD <br />I. FASTENERS FOR LATH TO BE NAILS OR � � i � INSTALL APPROVED HOUSEWRAP AIR <br />STAPLES IN COMPLIANCE W/ ASTM CI063 <br />INFILTRATION BARRIER OVER <br />2. WIRE TIES TO BE (NO. 18) 0.0415' WIRE / <br />SHEATHING <br />3. BLOCKING SHOWN MAY BE IN ADDITION \ <br />/ ELASTOMERIC COATING OVER STUCCO/ <br />TO WALL SCUDS REQUIRED PER PLAN <br />C.V. FINISH (SEE TYP WALL SECTION) <br />VERTICAL LATH <br />& PAPER DETAIL <br />\ / WOOD STUDS SECTION PER SECTION R703.7 <br />Exterior lathing and plastering <br />NOTE SHEATHING r Exterior use of portland cement plaster <br />SIDE LAPS OF METAL shall comply with the application <br />PLASTER BASES SHALL a requirements of ASTM C 926-12A. <br />BE SECURED TO BUILDING 6' MIN• Installation of exterior lathing and framing <br />„ „ FRAMING MEMBERS. PAPER LAP <br />1 M TYPE CONTROL JOINT THEY SHALL BE TIED shall comply with ASTM C 1063-12A. <br />BETWEEN SUPPORTS <br />WITH 0.0415-IN. (1.21-MM) STUCCO V LAP * LATH <br />WIRE At INTERVALS NOT <br /># 3' LAP ® PAPER <br />MORE THAN S' (22cJ-MM). w <br />AS PER ASTM CI063 a O f I f I ) I. FOLD INWARD * PT. A I. FOLD INWARD * PT. A 7 8.1• FIFE F I `� E T fRA T I O I � IDE T A � � (� � � / <br />®FOLD �^J 2• CREASE • PT. 8 4 K I C K O U T 3 <br />® O FOR REPAIR OF TEARS HORIZONTAL LATH N.T.&. <br />IN DETAIL MAY PATCHED ARs & PAPER DETAIL <br />W/HOUSE WRAP TAPE <br />PER MANUR SPEC. OR <br />FOLD PEEL 4 STICK <br />N7�.4y <br />O3 1. FOLD INWARD 4 1. FOLD INWARD • PT. A WOOD SHEATHING OR CMU <br />PT. A O 2. CREASE * PT. B WRB # LAYER 1, <br />2. CREASE a PT. ° 3. CREASE PT. c' ` STUCCO WRAP (FRAME ONLY) <br />3. CREASE * PT. C <br />4. FOLD PT. C OVER PT. <br />B TILL PT. C TOUCHES <br />BOOM`ANSsE <br />®" THICK, 3 COAT CEMENT <br />PLASTER (FRAME), 1/2" 2 COAT <br />CEMENT PLASTER (CMU)E N D <br />at A :. <br />LE(� <br />METAL LATH (FRAME ONLY) <br />LAP UJRB TAPE OVER DRAINAGE FL AN E (W 5 <br />® FOLD <br />© ROOF/UJALL SCREED <br />• „' BOTTOM G'� <br />FLANGE WATER TIGHTL A Y E fR 1* 1/ `•/ T U G G O WRAF) <br />SEAL. FOLD, 120- <br />HQI CUT. .� <br />THICK, 3 COAT CEMENT Z 5 "X5 a V TYPE CONTINUOUS WIR5 L A Y E fR 1*2 (F O RT F 15 E FR <br />PLASTER (FRAME), 1/2' 2 COAT -. GsALV. METAL FLASHING <br />CEMENT PLASTER (CMU) ? (NAIL TO ROOF DECK, NOT 5 U I L D I NG P A P E R <br />WRB LAYER 02, FORTIFIBER WALL SHEATHING)BUILDING PAPER (FRAME ONLY) <br />WRB LAYER 01, N CAP SHINGLE — DO NOT NAIL, METAL LATH X X X X <br />� ~''�" STUCCO WRAP(FRAME ONLY) <br />i y=�1,it. ' h <br />r-. INSTALL WITH ROOF CEMENT Q <br />LAP LAYERS OF BUILDING WRAP <br />:a4��i'r"ri.`" e7 OVER NAILING FLANGE, STOP <br />WRB APPROX. I yt' ABOVE • ='�•t� y SHINGLES (FRAME ONLY) V C� It <br />U C C O ° <br />FRAME OR CMU i <br />' EXTERIOR \ <br />'ROOFAUALL SCREED ROOF CEMENT <br />..... >= ROOF PER ELEVATIONS WOOD &HEATH INCH <br />U14UP <br />15x8 WALL FLASHING ;p <br />KICK -OUT FLASHING (SEE �r1 <br />DETAIL) •j•� \ &ELF-AF_.)HE&I it E FLA` HIND <br />NOT <br />t�-ITAL LATH: LATH TO 5E FER SECTION <br />FELTAYMENT t <br />WATER TIGHT SEAL (BEND OR <br />� 0 v' NOTE: INSTALL KICKOUT SOLDER DO NOT CUT) R 1 0 3.7 .1 / A & T �l C — a 4 l — O J / �1 (N . 25 L55, <br />SHINGLE ROOFING (6 FLASHING AT BOTTOM OF ROOF 4 F E R & VG . A � \ U T (Ls I T � OR N O � (N A L. <br />WALL INTERSECTIONS <br />DRIP EDGE: OVERLAP 3', <br />EXTEND I/2'BELOW LATH FDOE& NOT-1"IEET SPECIFICATIONS) <br />SHEATHING, MECHANICALLY FASCIA WRAP <br />FASTEN 4' O.G. MAX " L" F LAS H I N G <br />5 <br />N,T.S, <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngro'up.com <br />AA #: 0003325 <br />h <br />W <br />x <br />ID <br />� <br />U <br />� <br />0 <br />W <br />O <br />Lu <br />U <br />W <br />W <br />L; <br />tot <br />Ll <br />C1 <br />pLU <br />e <br />o <br />> <br />A <br />+n <br />0 <br />61 <br />dl <br />0 <br />0 <br />C <br />A <br />0 <br />A <br />V <br />Cn <br />SUBDIV. & LOT: <br />ABBOTT <br />PARK <br />LOT #38 <br />BLK #9 <br />PROJECT# <br />04181.000— 38091 <br />MODEL: <br />3EFB <br />"2447— ROBIE" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />60 MPH EXP. C <br />PRINT 05 26 20 <br />DATE.• <br />SCALE: 1/4" = 1'-0" <br />SHEET <br />WAI <br />„ice 6 is,u,,: ,i _...ti _ �I I � I �� i I i � � � I _ � - _ � � I I:� 4,.,1 i il�.r � I�il -�i i�a�� s•.���'�`:.�Vll��.i I <br />