c <br />a <br />Lf <br />2'-0" <br />16'-0" <br />20'-0" <br />9a,-.q" <br />29'-8" <br />2'-0" 11'-4" <br />FOUNDATION PLAN <br />SCALE: 1/4 = 1'-0" <br />7'-0" 11'-4" <br />mi <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +-0'-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION +4-0", SEE SURVEY PLOT FOR NGVD. <br />5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11.0INDICATED #5 BAR, ElINDICATES #6 BAR,OINDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 900 <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30", #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, USING: F'm = <br />1,500 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN <br />RUNNING BOND. <br />16, WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER 3 OF SLAB SUPPORTED <br />3'-0" O/C MAX. SEE PLAN FOR WWM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 6th EDITION <br />SLAB SCHEDULE <br />SLAB <br />THICKNESS <br />REINF. <br />REMARKS <br />6x6 W1.4xW1.4 OVER <br />GENERAL <br />3 1/2" <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS, SAME SIZE QUANTITY AS BARS IN FOUNDATION, WITH 30" LEG EACH WAY. <br />MARK <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />FM-12x18 <br />12" <br />CONTINUOUS <br />18" <br />- <br />(2) #5's <br />- <br />(+)0'-0" <br />FM-16x18 <br />16" <br />CONTINUOUS <br />18" <br />- <br />(2) #5's <br />_ <br />(+)0"-0" <br />FMC-16x18 <br />16" <br />CONTINUOUS <br />18" <br />- <br />(2) #5's <br />VARIES <br />CW-12x12 <br />12" <br />SEE PLAN <br />12" <br />- <br />(2) #5's <br />- <br />(+)0"-0" <br />CWC-12x12 <br />12" <br />SEE PLAN <br />12" <br />- <br />(2) #5's <br />VARIES <br />TE-2 <br />12" <br />SEE PLAN <br />8" <br />- <br />(2) #5's <br />_ <br />(+)0"-0" <br />F-24x24 <br />24" <br />24" <br />12" <br />(2) #5's <br />(2) #5's <br />_ <br />(+)0"-0" <br />TE-1 <br />8" <br />SEE PLAN <br />8" <br />- <br />(2) #5's <br />_ <br />(_)0.4 <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />w <br />v <br />J <br />CA <br />O <br />ui <br />` <br />w <br />°L <br />r <br />o <br />(L <br />i <br />a <br />( <br />e <br />`p <br />oc <br />4 <br />ry <br />-I <br />Lu <br />d <br />Ll <br />Lu <br />cl <br />a <br />i <br />EW <br />C <br />0 <br />0 <br />v <br />0 <br />C <br />lop <br />SUBDIV. & LOT: <br />ABBOTT <br />PARK <br />LOT #38 <br />BLK #9 <br />PROJECT# <br />04181.000— 38091 <br />MODEL: <br />3EFB <br />"2447— ROBIE" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />FOUNDATION <br />PLAN <br />60 MPH EXP. C <br />PRINT <br />DATE: 05/26/20 1 <br />' SCALE: 1/411 = 1'-01' 1 <br />SHEET <br />sl <br />