Laserfiche WebLink
STRUGTURAL MOTES <br />I. SPEG I F I GATI ONS <br />I. I. GONSTRUGTION <br />I. I. I. AGI 318-02 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. I. 2. AGI 530/A5GE 5/TM5 402-qq ff AGI 550, I/A5GE 6/TM5 ro02-qq <br />SPE6IFIGATION5 FOR MASONRY STRUCTURES. <br />I. 1. 3. A5TM G2-10-c12, G4-76-q1, AND G90-QO SPECIFICATIONS FOR MASONRY STRUCTURES <br />1. I. 4. NATIONAL DESIGN SPECIFICATIONS (ND5) FOR WOOD CONSTRUCTION, 2001 EDITION, AND ALL <br />r AGCOMPANYING SUPPLEMENTS. <br />1. I. 5. FLORIDA BUILDING CODE (FBG), 2001 EDITION <br />1. 1.6. "MANUAL OF STEEL CONSTRUCTION, ALLOWABLE STRESS DESIGN", BY THE AMERICAN <br />INSTITUTE OF STEEL CONSTRUCTION, (AISG) CITH EDITION. <br />I. I. 7. "DE516N SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />TRU55 PLATE INSTITUTE (TPU Igg5 EDITION. <br />1. 2 . DES I ON : <br />I. 2. I. AGI 318-02 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />I. 2. 2. AGI 530/A5GE 5/TM5 402-qq t AGI 550, I/A5GE 6/TM5 602-qq <br />SPECIFICATIONS FOR MASONRY STRUCTURES. <br />I. 2. 3. ASTM G270-q2, G476-q1, AND G110-qO SPECIFICATIONS FOR MASONRY STRUCTURES <br />1. 2. 4. NATIONAL DESIGN SPECIFICATIONS (ND5) FOR WOOD CONSTRUCTION, 2001 EDITION, AND ALL <br />ACCOMPANYING SUPPLEMENTS. <br />I. 2. 5. PLYWOOD DESIGN SPECIFICATIONS (APA) <br />I. 2. 6. FLORIDA BUILDING CODE (FBG), 2001 EDITION <br />I. 3. SHOP <br />DRANINOS : <br />I. 3. I. <br />THERE SHALL NOT BE ANY DEVIATIONS FROM THESE DESIGN PLANS BY OTHERS <br />DURING THE PREPARATION OF SHOP DRAWINGS <br />WITHOUT WRITTEN APPROVAL FROM <br />THE ENGINEER OF RECORD. <br />I. 3. 2. <br />ALL SHOP DRANIN65 ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO <br />THE COMMENCEMENT OF CONSTRUCTION. <br />I. 3. 3. <br />ALL ROOF AND FLOOR TRUSS SHOP DRAHIN05 <br />ARE TO BE SIGNED AND SEALED BY A <br />FLA. RE6. PE. AND SHALL INCLUDE : DRAWINGS AND CALCULATIONS, REACTIONS AND <br />BEARING POINTS, BRACING REOUIREMENT5, AND CONNECTIONS TO <br />SUPPORTING TRU55 MEMBERS. <br />2. DES I C-7N LOADS <br />2.1. DEAD <br />LOADS <br />2. i. I. <br />UNIT HEIGHT OF SOIL, COMPAGTED : <br />120 PGF <br />2. 1. 2. <br />UNIT I^EIGHT OF REINFORCED CONCRETE <br />150 PGF <br />2. 1. 3. <br />UNIT HEIGHT OF 8" G.M.U. BLOCK : <br />40 PSF <br />2. 1. 4. <br />IST FLOOR SUPERIMPOSED LOAD <br />20 P5F <br />2. 1. 5. <br />UNIT HEIGHT OF 2x4 PARTITION HALLS : <br />II PSF <br />2. I. 6. <br />UNIT HEIGHT OF 2x6 BEARING HALLS : <br />12 PSF <br />2. 1. 7. <br />BALCONIES 8 PECKS: <br />15 PSF <br />2. 1. 8. <br />TILE ROOF <br />TOP CHORD <br />15 PSF <br />BOTTOM GHORD <br />10 PSF <br />2. I. q. <br />SHINGLE ROOF <br />TOP CHORD <br />7 PSF <br />BOTTOM CHORD <br />10 P5F <br />2. I. 10. <br />FLOOR TRUSSES <br />15 <br />2.2. LIVE LOADS : <br />2. 2. 1. <br />SIDEHALK AND DRIVEWAY LOAD <br />200 P5F <br />2.2.2. <br />GARAGE LOADS: <br />50 P5F <br />2.2.5. <br />CORRIDORS AND BATHROOMS: <br />80 P5F <br />2.2.4. <br />PARTITIONED ROOMS: <br />40 P5F <br />2.2.5. <br />BALCONY AND DECKS : <br />40 PSF <br />2. 2. 6. <br />STAIRHAYS AND LANDING-5: <br />40 P5F <br />2.2.7. <br />ROOF: <br />20 PSF <br />2. 2. 8. <br />FLOOR TRU55 <br />TOP CHORD MINIMUM: <br />40 P5F <br />2. 2. q. <br />ROOF TRUSS <br />TOP CHORD MINIMUM: <br />20 PSF <br />i <br />F. <br />a <br />a <br />2. 3. RAILING LOADS : <br />2. 3. I. <br />ALL RAILING AND GUARD RAIL 5Y5TEM'S ARE TO BE DESIGNED TO WITHSTAND A <br />CONCENTRATED LOAD OF 200 POUNDS APPLIED AT ANY POINT AND IN ANY <br />DIRECTION ON THE RAILING. <br />2.3.2. <br />ALL RAILING AND GUARD RAIL 5Y5TEM'S ARE TO BE DESIGNED TO NITH5TAND A <br />HORIZONTAL LOAD OF 50 PLF ON THE GUARDRAIL AND A SIMULTANEOUS LOAD <br />OF 100 PLF APPLIED VERTICALLY DONNHARD AT THE TOP OF THE GUARDRAIL <br />2.5.3. <br />GUARDRAIL SYSTEM SHALL BE DESIGNED TO HIT145TAND 200lb CONCENTRATED <br />HORIZONTAL LOAD APPLIED ON 1 50. FT. AT ANY POINT IN THE 5Y5TEM. <br />2.3.4. <br />2.3.1., 2.5.2 4 2.53. ARE NOT REQUIRED TO BE APPLIED SIMULTANEOUSLY, BUT EACH <br />SHALL BE APPLIED TO PRODUCE THE MAXIMUM STRESSES IN THE MEMBER COMPONENTS. <br />2. 4. WIND <br />LOADS : <br />2. 4. I. NINO DE51ON TO BE GONDUCTED IN ACCORDANCE HITH SECT. 1606 OF THE <br />FBG, 2001 EDITION, AND CONDUCTED BASED ON A 120 MPH, 3 SECOND 67U5T, <br />EXPOSURE "B", IMPORTANCE FACTOR "I" = I.O. ENCLOSED BUILDING. <br />2.4.2. NET UPLIFT DEAD LOADS - 10 PSF SHINGLE, 15 PSF TILE <br />2.5. DEFLEGTIONS <br />2. 6. I. FLOOR TRUSSES SHALL LIMIT DEFLECTION TO 1/360 TIMES THE SPAN FOR LIVE LOADS <br />AND 1/240 TIMES THE SPAN FOR TOTAL LOAD. <br />STRUGTURAL NOTES <br />DESIGN METHOD <br />3 I LOPED FACTOR DESIGN <br />3. I. I. THE LOAD FACTOR DE51GN METHOD WAS USED TO PE516N <br />GA5T-IN-PLACE CONCRETE SLABS AND FOOTINGS <br />5. 2. SERV I GE LOAD DES ON <br />3. 2. I. THE SERVICE LOAD DESIGN METHOD WAS USED TO DESIGN <br />MASONRY WALLS AND LINTELS <br />INTERIOR AND EXTERIOR WOOD FRAMING AND SHEATHING <br />STAIRS AND FLOOR FRAMING <br />ROOF FRAMING, SHEATHING AND UPLIFT <br />3. S. LOPED COMBINATIONS FOR LFRO DESIGNS <br />THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED FOR: <br />TOTAL OL + FLOOR LL + ROOF LL <br />TOTAL DL + FLOOR LL + HL <br />TOTAL DL + WL <br />5.3.2. ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED TO RE515T THE WORST LOAD <br />GOM13INATION RESULTING IN THE MAXIMUM STRESSES PLACED ON THAT COMPONENT. <br />BOTH PARTIAL, FULL; AND ALTERNATING SPAN LOADING ARE TO BE CONSIDERED. <br />3. 4. DESON ASSUMPTIONS : <br />3. 4. I. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALL5 UNLESS <br />5HOHN OTHERWI5E IN THE DESIGN PLANS. <br />4. MATERIALS <br />4.1. RE I NFORG I NO STEEL : <br />4. I. I. <br />REINFORGIN6 STEEL SHALL BE A5TM A615-q4 GRADE 40, f'y = 40 Ksl <br />4. I. 2. <br />LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 BAR 20", #3 BAR 15". <br />4. I. 3. <br />ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORGING ARE TO THE <br />GENTERLINE OF EACH BAR EXCEPT WHERE THE COVER DIMENSION 15 5HOHN TO THE <br />FACE OF THE CONCRETE. <br />4. I. 4. <br />REINFORCING DETAIL DIMEN51ON5 ARE OUT TO OUT OF BARS. <br />4. I. 5. <br />REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP 125 % OF THE REQUIRED <br />YIELD 5TRENOTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF <br />RECORD. <br />4. I. 6. <br />OE51ON COVER REQUIREMENT5 <br />0-1-P CONCRETE FORMED AGAINST EARTH; 3" <br />G-I-P GONCRETE EXPOSED TO EXTERIOR: 2" <br />G-I-P CONCRETE NOT EXPOSED : 1 1/2" <br />GROUT FILLED MASONRY: 3/4" <br />PRE 5TRE55ED CONCRETE LINTELS (ADD. REBAR IN) : 1 1/2" <br />PRE CAST GROUT FILLED LINTELS (ADD. REBAR IN) : 1 1/2" <br />4. 1. 7. <br />MELDED HIRE FABRIC (WHF): ASTM A185-clOa. <br />4. I. 8. <br />DETAIL REINFORCEMENT IN ACCORDANCE WITH AGI 315-LATE5T EDITION. <br />4. 2. GONGRETE <br />4. 2. I. <br />CONCRETE TYPE <br />MIN. 28 DAY <br />DESIGN (f'c) <br />MODULES OF <br />ELASTICITY <br />DESIGN (E) <br />6-1-P CONCRETE (NORMAL HEIGHT) <br />2,500 Psi <br />2,850 K51 <br />G-I-P GROUT <br />2,500 Psi <br />2,850 K51 <br />PRE CAST CONCRETE LINTELS <br />5,000 Psi <br />5,122 Ksi <br />PRE 5TRE55ED CONCRETE LINTELS <br />5,000 Psi <br />4,030 Ksl <br />4.2.2. CONCRETE SHALL CONSIST OF I" MAXIMUM AGGREGATE CONCRETE MIX HITH SLUMP <br />BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />4.2.5. GROUT SHALL GON515T OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX <br />HITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR <br />ADDITIONAL CRITERIA. <br />4.2.4. CONSTRUCTION JOINTS HILL BE PERMITTED <br />4.2.5. METHOD OF CONCRETE FORMING, PLACEMENT AND GURING SHALL BE CONDUCTED IN <br />ACGORPANGE HITH THE SPECIFICATIONS AS STATED. <br />4. 2. 6. EARTH SUPPORTED SLAB5 (EXCLUDING EXTERIOR WALKWAYS s DRIVEWAYS) <br />3 1/2" MIN. THICKNE-55 H/ MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 HWF <br />MID -DEPTH OF 5LA8. FIBER MESH MAY BE USED I.L.O. HHF @ CONTRACTORS DISCRETION. <br />4. 2.1. CONCRETE PLACEMENT PRACTIGES SHALL BE IN ACCORDANCE W/ ALL <br />AGI- MCP Iggq STANDARDS. <br />4. 3. CONCRETE MA50NRY : <br />4. 3. I. FILLED GELLS H/ (1) #5 BAR SHALL BE LOCATED @ 8'-0" O.G. MAX, @ BOTH SIDES <br />OF OPENIN65 6-0" NIOE OR MORE, 0 THE HIGH SIDE OF ALL MASONRY HALL <br />STEPS, 8 ® ALL GHANGE5 IN DIRECTION OF THE MASONRY NALL5. <br />4.3.2. LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE ASTM G90- 10, TYPE II <br />NON -MOISTURE CONTROLLED. <br />4.3.5. ALL CELLS � CAVITIES BELOW GRADE HILL BE FILLED N/ CONCRETE IN ALL <br />STEM HALLS. <br />4.3.4. THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI <br />MINIMUM. <br />4.3.5. METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE <br />CONDUCTED IN ACCORDANCE HITH THE SPECIFICATIONS A5 STATED. <br />4.3.6. MORTAR SHALL BE TYPE "S" FOR ALL MASONRY CONSTRUCTION. <br />4. 3. 7. LINTELS SUPPLIED 13Y APPROVED MANUFACTURER: <br />1) FEGP/GAST-GRETE CORPORATION <br />2) POWER CONCRETE <br />3) ALLIED PRECAST <br />4) LOTT <br />5) MARION MASONRY <br />6) HIEKHA <br />STRUGTURAL MOTES <br />4.4. STRUGTURAL LUMBER : <br />4. 4. I.I. INTERIOR LOAD BEARING WALL5 S.P.F., fb = 675 P51, E = 1200 K51 <br />ALL EXTERIOR FRAMING 5.P.F., fb = 615 PSI, E = 1200 Ksi <br />4. 4. 1.2. ALL FRAME WALLS TO BE CONSTRUCTED U51NG S.P.F. , <br />STUD QUALITY OR BETTER <br />4.4.2. ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS <br />SHALL BE APA RATED SHEATHING EXP l U.N.O. <br />4.4.5. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND <br />SHEAR HALL5 SHALL BE APA RATED SHEATHING EXP I U.N.O. <br />4.4.4. IF OSB BOARD 15 TO BE USED IN PLACE OF PLYWOOD 15 TO HAVE 51MILAR OR <br />GREATER SECTION PROPERTIES. <br />4.4.5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN <br />CONTACT WITH CONCRETE 15 TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />4.4.6. WHEN PRE ENGINEERED TRU55E5 ARE GALLED FOR ON THE PLANS THE <br />MANUFACTURER 15 TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. <br />4.4.7. DESIGN, FABRICATE AND ERECT WOOD TRU55E5 IN ACCORDANCE WITH THE "DESIGN <br />SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRU55E5" BY THE <br />AN51/TPI I-Igg5, HIB-ql AND 05T-88. <br />4. 4. 8. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES <br />SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />4. 4. q. ALL EXTERIOR FRAME WALLS SHALL HAVE 7/8" STUGGO FIN15H PER A5TM G. q26. <br />APPLY 3 LAYERS W/ THICKNESS OF 7/8" OVER METAL LATH. FIRST 2 LAYERS 3/8" THICK. <br />EACH, AND 3RD LAYER I/8" THICK. <br />4. 5. FASTENERS AND TIE DOWNS : <br />4. 5. I. <br />FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, CHANNELS : A5TM A36-361-1 q4 Fy = 36 K51 <br />ROUND METAL PIPE : A5TM A53-q4, GRADE B Fy = 35 K51 <br />SQUARE METAL TUBING : ASTM A500-614, GRADE B Fy = 46Ksi <br />HIGH 5TRENGTH BOLTS : A5TM A325- 14 <br />MACHINE BOLTS: GALVANIZED A5TM A307-q4 <br />4.5.2. <br />SHEET METAL ACCESSORIES SHALL CONFORM TO : Fy = 33KsINITH Gq0 <br />GALVANIZED COATING IN AGGORDANGE KITH ASTM A525-87. <br />4.5.3. <br />NAILS SHALL CONSIST OF : COMMON HIRE NAILS KITH MINIMUM DIAMETER AS <br />FOLLOH5 : Sd = 0.115", IOd = 0.128", 12d = 0.125", 16d = 0.135". <br />4.5.4. <br />ALL FASTENERS AND TIE DOHN5 EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE GOATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DOHN5 ARE TO PROVIDE THE UPLIFT CAPACITY GALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />4.5.6. <br />ALL FASTENER TIE DOWN5, BEAM HANGER5, JOI5T HANGER5, AND FLOOR TRUSS <br />STRAPPING ARE TO BE INSTALLED IN ACCORDANCE KITH THE PLANS AND <br />SPECIFICATIONS. <br />4.5.1. <br />CONCRETE EMBEDDED 'J' BOLT5 USED FOR UPLIFT ARE TO BE NET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, 5PAGIN6 AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />HITH THE DESIGN PLANS, U.N.O. ALTERNATE-5 TO "J" BOLTS ARE NOTED ON PLANS. <br />4.5.8. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRU55 AND HALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRIOR TO PLACING GROUT. <br />4. 6. MICRO <br />-LAM LUMBER: <br />4. 6. 1. <br />MIGRO-LAM 5TRE55 GRADE5 SHALL PROVIDE THE FOLLOWIN6 MINIMUM PROPERTIES: <br />E = 2,000,000 P51 <br />Flo = 2,6150 P51 <br />Ft = 1850 PSI <br />Fc = 500 P51 (PERPENDICULAR) <br />Fc = 2300 (PARALLEL) <br />Fv = 285 P51 <br />4. -T. STEEL: <br />4. 7. I. INSTALLATION OF ALL STEEL TO BE PERFORMED BY AN EXPERIENCED, QUALIFIED <br />STEEL ERECTOR. <br />4.1.2. FABRICATE AND ERECT ALL 5TRUGTURAL STEEL IN ACCORDANCE HITH A.I.S.G. <br />"SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS". <br />5TRUGTURAL STEEL: ASTM A36-36M c14. <br />4. 7. 4. STEEL TUBING: A5TM A500-q4, GRADE B. <br />4. 7• 5.. WELDED CONNECTIONS: E70XX ELECTRODES, MINIMUM 51ZE FILLET HELPS 3/16", AN5 <br />CERTIFIED HELPERS. CERTIFICATION PAPERS TO BE SUBMITTED UPON REQUEST. <br />4. 7. 6. WHERE STEEL BEAMS ARE CONTINUOUS OVER COLUMNS, PROVIDE NEB STIFFENER <br />PLATES ON EACH SIDE OF THE HEB, OF A THIGKNE55 EQUAL TO BEAM FLANGE <br />THICKNESS, LOCATED AT THE CENTER LINE OF THE TUBE COLUMN. <br />4.1.1. THE 5TEEL FRAME 15 "NON -SELF SUPPORTING". ADEQUATE TEMPORARY SUPPORT <br />SHALL BE PROVIDED BY THE CONTRACTOR UNTIL REQUIRED CONNECTIONS OR <br />ELEMENTS ARE IN PLACE. <br />STRUGTURAL DOTES <br />4. 8. SOIL: <br />4. 8. I. MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. <br />4. 8. 2. ALL SOIL 15 TO BE GLEAN S POISONED FOR TERMITES PER FBG 2001 SECTIONS <br />104.2.6, 104.2.7, 1403.1.6, 1503.4.4, 1816, Ici167.5, 2303.1.4, ff 2304. <br />TERMITE PROTEGTI ON - <br />PLANS MUST SPEG I FY TYPE OF TERMITE TREATMENT <br />0 Soil Chemical Barrier Method <br />a Other treatment - Must specify proposed method and submit documentation, which <br />substantiates the proposed method, 15 an approved termite protection system or method. <br />IF GHEM I GAL SOIL TERMITE TREATMENT 15 USED <br />1. FBG 104.2.E - "A permanent sign which Identifies the termite treatment provider <br />and need for re -inspection and treatment contract renewal shall be provided. <br />The sign Shall be posted near the water heater or electric panel" <br />2. FBG 1503.4.4 - Condensate and roof downspouts shall discharge at least <br />1'-0" away from the building 51de walls. <br />3. FBG 1503.4.4 - Irrigation/sprinkler systems including all risers and <br />spray heads shall not be installed within 1'-0" of the building side wall. <br />4. FBG 1403.1.E - To provide for inspection for termite infestation, between <br />wall covering and final earth grade shall not be less than 6 Inches. <br />Exception: Paint or decorative cementitious finish less than 5/8" <br />thick adhered directly to the foundation wall. <br />5. FBG 1816.1.1 - initial treatment shall be done after all excavation <br />and backfill is complete. <br />6. FBG 1816.1.2 - Soil disturbed after the initial treatment shall be retreated <br />including spaces boxed or formed. <br />7. FBG I816.1.3 - Boxed areas in concrete floors for subsequent installation of traps, <br />etc., shall be made with permanent metal or plastic forms. Permanent forms must be <br />of a size and depth that will eliminate the disturbance of soil after the initial treatment. <br />8. FBG 1816.1.4 - Minimum 6 mil vapor retarder must be installed to protect against <br />rainfall dilution. If rainfall occurs before vapor retarder placement, <br />retreatment 15 required. <br />q. FBG 1816.1.5 - Concrete overpour and mortar along the foundation perimeter <br />must be removed before exterior roil treatment. <br />10. FBG 1816.1.6 - Soil treatment must be applied under all exterior concrete <br />or grade within 1'-0" of the structure sidewalls. <br />IL FBG 1816.1.6 - An exterior vertical chemical barrier must be installed after <br />construction Is complete, including landscaping and irrigation. Any soil disturbed <br />after the vertical barrier 15 applied, shall be retreated, <br />12. FBG 1816.1.-T - All buildings are required to have pre -construction treatment.. <br />13. FBG 1816.1.7 - A certificate of compliance must be issued to the building department <br />byy a licensed pert control company before a certificate of occupancy will be 155ued. <br />T P, certificate of compliance shall state: "The building has received a complete <br />treatment for the prevention of subterranean termites. The treatment is in <br />accordance with the rules and laws of the Florida Department of Agriculture <br />and Consumer Services". <br />14. FBG 2503.1.5 - After all work is completed, loose wood and fill must be removed <br />from below and within 1'-0" of the building. This includes all grade stakes, <br />tub trap boxes, forms, shoring or other cellulose containing material. <br />15. FBG 2305.1.4 - No wood, vegetation, stumps, cardboard, trash, etc., <br />shall be buried within 15'-0" of any building or proposed building. <br />4. 8. 3. SOIL 15 TO BE COMPACTED TO q5% MODIFIED PROCTOR AS DEFINED BY <br />ASTM D 1557-qI <br />ATTENTION: CHEMICAL CHANGES iN PRESSURE TREATEO WOODS <br />AS OF DECEMSER 318T, 2003, CHROMATED COPPER ARSENATE (CCA-C) <br />WILL NO LONGER SE PRODUCED FOR RESIDENTiAL OR GENERAL <br />CONSUMER USE. SEVERAL NEW PRESSURE TREATED WOOD ALTERNATIVES <br />HAVE $EEN CREATED TO REPLACE CCA-C. MANY OF THE NEW PRESSURE <br />TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. iT IS <br />THE CONTRACTOR'S RESPONS181LITY TO VERIFY THE TYPE OF WOOD <br />TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST <br />CORROSION, FOR EXAMPLE, ACQ-C, ACQ-D, CSA-A, OR CA-5 REQUIRE <br />HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM <br />BORATE (SSX) DOES NOT, <br />A1RE\ASED 08-15-03 <br />AoCREATED 01-02-02 <br />120 MPH <br />3 SEC. GUST <br />❑ SAMUEL A. GcREEN5ERG, P.E. *34245 <br />❑ THUY H. HUYNH, P.E. %0122 <br />❑ IRWIN J. SENSON, P.E. 049156 <br />❑ AL I A55AS HAKIM, P.E. S6186 <br />TO THE BEST OF THE ENGINEER'S 1040U-EDW AND BELIEF, THE <br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE <br />FLORIDA BUILDING CODE, SECTION 160E FOR 120 MPH 3 SECOND <br />GUST, EXPOSURE 15' WIND ZONE (2001 EDITION). <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IT IS SIGNED AND SEALED. <br />Sr*m AND SEALED FOR THE STRUCTURAL. PORTION OF THIS <br />DRAWING ONLY. <br />-�- h I I TT 71 � i JiT II I I. i l!Tl� ill &:L➢T1 Li 9i U l l Al � i s l i71�Mil A l TT i, l Lr; r ri - T r - <br />