My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Walmart 0706
Zephyrhills
>
Building Department
>
Building Plans
>
Walmart 0706
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:11:01 AM
Creation date
2/27/2025 11:30:27 AM
Metadata
Fields
Template:
Building Plans
Location
Walmart 0706
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REFRIGERATION SCHEDULE SYSTEM LTB <br />Refrig. OEM: <br />Hill Phoenix <br />Condenser Type: <br />Air <br />Heat Reclaim Media: <br />Water <br />SG1 Refrig. Liquid Temp (°F): <br />45 <br />SG2 Refrig. Liquid Temp (°F): <br />N/A <br />SG3 Refrig. Liquid Temp (°F): <br />NIA <br />! <br />EXTERIOR DRY BULB (DB) (°F): <br />5 yr. Extreme DB from ASHRAE Pub. <br />96.9 <br />2017 <br />RackBCapacity <br />Total Available Capacity <br />Previous Req'd Capacity <br />215.3 <br />202.3 <br />MBH <br />MBH <br />Format: Walmart <br />Store #: 706 <br />System Type: Compressor House <br />Refrigerant: R407A <br />Refrig. BAS: Novar <br />Sat. Cond. Temp (°F): 112 <br />Heat Reclaim Use: N/A <br />SG1 Comp RGT (°F): 30 <br />SG2 Comp RGT (°F): N/A E SG3 Comp RGT (°F): N/A <br />Proto Size: Cap-X <br />City/State: Zephyrhills, FL <br />Consultant: GPW & Associates <br />Estimated Refrigerant Charge (lbs): <br />N/A <br />System Elec: <br />460V 3Ph 60Hz <br />Cond. Design TD (°F): <br />15 <br />Heat Reclaim Water (GPM): <br />_ <br />EXTERIOR WET BULB (WB) (°F): <br />0.4% Monthly Max WB from ASHRAE Pub. <br />81.7 <br />2017 <br />Removed Capacity <br />Added Capacity <br />13.7 <br />0.0 <br />MBH <br />MBH <br />Proto Cycle Date: 1/31/2022 <br />Elevation (ft): 0 <br />Prepared By: NHA <br />Rack & Cond. Charge (lbs): XX <br />Defrost Elec: 208V 3Ph 60Hz <br />Est. Summer THR (MBH): N/A <br />Evap. Superheat (°F): <br />Date Prepared: 2/11/2022 <br />Design DB (°F) ! WB (°F): 94.4°F ! 81.7°F <br />Intenor Design DB (°F) / RH°k: 75°F / 55°lo <br />Fixture and Field Piping (lbs): <br />N/A <br />Sys. Pilot Elec: <br />280V 1 Ph 60Hz - <br />Cond. Elec. <br />460V 3Ph 60Hz <br />Est. Winter THR Avail (MBH): <br />N/A <br />ASHRAE Design Conditions Weather Station: HERNANDO COUNTY AP, FL <br />New Req'd Capacity <br />188.6 <br />MBH <br />CIRCUIT INFORMATION <br />FIXTURE ELECTRICAL <br />INFORMATION <br />CKT # <br />Case Fixture Length / Quantity <br />Walk-in Box Size <br />Case/Coil Model <br />Case/Coil Manuf. <br />Application <br />LSHX Y or N? <br />& Model # <br />WI Evaps <br />Evaporator <br />Coil TXV ! <br />Distributor Nozzle <br />Sub -Circuit Load <br />(MBH) <br />Circuit <br />Load (MBH) <br />Evap <br />SST <br />Case/ <br />Walk -In <br />Air Temp <br />Circuit Control Valves <br />Defrost <br />Type <br />Defrost Heaters <br />Fans <br />Lights <br />Amps <br />(120v) <br />Anti -Sweat <br />Amps <br />(120v) <br />j <br />Comments <br />Equip Number <br />CKT # <br />FT /# of Doors <br />2 Dr/4' <br />3 Dr/6' <br />4 Dr/8' <br />5 Dr/12' <br />L <br />W <br />H <br />EPR <br />LLSV <br />Amps <br />Voltage <br />Amps <br />Voltage <br />B01 <br />17 DOORS <br />1 <br />1 <br />2 <br />RMZC30 <br />ZERO ZONE <br />M/D REACH -IN I.C. DOORS <br />- <br />27.3 <br />-20 <br />SORIT20 <br />ME6 <br />ELEC <br />35.1 <br />208/3 <br />5.8 <br />115/1 <br />EXISTING CASE <br />B01 <br />B02 <br />17 DOORS <br />1 <br />1 <br />2 <br />RMZC30 <br />ZERO ZONE <br />M/D REACH -IN I.C. DOORS <br />27.3 <br />-20 <br />SORIT20 <br />ME6 <br />ELEC <br />35.1 <br />208/3 <br />5.8 <br />115/1 <br />j <br />EXISTING CASE <br />B02 <br />B03 <br />NEW SPARE <br />-- <br />i <br />-- <br />- -- - <br />---- <br />-B03 - <br />B04 <br />2 ENDS <br />2 <br />NFJE <br />HILL PHOENIX <br />DUAL TEMP END CASES <br />5.2 <br />-27 <br />SORIT12 (DT) <br />ME6 <br />ELEC <br />17.2 <br />208/1 <br />2.0 <br />1 115/1 <br />EXISTING CASE <br />B04 <br />B05 <br />24' <br />3 <br />NFJE <br />HILL PHOENIX <br />DUAL TEMP COFFIN <br />15.0 <br />-27 <br />SORIT15 (DT) <br />ME6 <br />ELEC <br />27.3 <br />208/3 <br />6.0 <br />115/1 <br />EXISTING CASE <br />805 <br />B06 <br />2 DOORS <br />1 <br />RL <br />HUSSMANN <br />FROZEN BAKERY REACH -IN <br />2.7 <br />-22 <br />SORIT12 <br />ME6 <br />ELEC <br />6.7 <br />208/1 <br />3.1 <br />115/1 <br />EXISTING CASE <br />B06 <br />B07 <br />247ENDS <br />2 <br />3 <br />NFJ/NFJE <br />HILL PHOENIX <br />DUAL TEMP COFFIN W/ ENDS <br />20.2 <br />-27 <br />SORIT20 (DT) <br />ME6 <br />ELEC <br />35.7 <br />208/3 <br />8.0 <br />115/1 <br />; <br />EXISTING CASE <br />B07 <br />B08 <br />18 <br />19 <br />12 <br />BME260C <br />BOHN <br />ICE CREAM FREEZER <br />EGVE2Z / E1 1/2 <br />23.1 <br />-20 <br />SORIT15 (DT) <br />ME6 <br />ELEC <br />16.0 <br />208/3 <br />3.6 <br />208/1 <br />EXISTING EVAPORATOR <br />B08 <br />B09 _ <br />18 <br />44 <br />12 <br />(2) BME190C <br />BOHN <br />GROCERY FREEZER <br />EGVE2Z / G 1 <br />37.4 <br />-10 <br />SORIT20 <br />_ ME6 <br />ELEC <br />32.0 <br />208/3 <br />7.2 <br />208/1 <br />EXISTING EVAPORATOR_ <br />J <br />_ - - <br />- - <br />B_09 <br />- <br />B10 <br />247ENDS <br />2 <br />2 <br />FWG/FWEG <br />HILL PHOENIX <br />DUAL TEMP COFFIN W/ENDS <br />12.3 <br />-22 <br />CDST-79 <br />E3 <br />ELEC <br />36.2 <br />20811 <br />0.7 <br />115/1 <br />EXISTING CASE <br />B10 <br />B11 <br />SPARE <br />EXISTING CASE <br />611 <br />B12 <br />167ENDS <br />2 <br />2 <br />NFJ/NFJE <br />HILL PHOENIX <br />DUAL TEMP COFFIN <br />15.2 <br />-27 <br />1 <br />1 SORIT15 <br />ME6 <br />ELEC <br />26.9 <br />208/3 <br />6.0 <br />115/1 <br />; <br />EXISTING CASE <br />B12 <br />B13 <br />8' <br />1 <br />NFN <br />HILL PHOENIX <br />FROEN SEAFOOD COFFIN <br />2.9 <br />-27 <br />SORIT12 <br />ME6 <br />ELEC <br />6.9 <br />208/1 <br />2.8 <br />115/1 <br />EXISTING CASE <br />B13 <br />SUCTION GROUP #1 REQUIRED CAPACITY (MBH): <br />188.6 <br />-27 <br />(°F) Suction Temperature <br />B14 <br />General Notes: <br />1 •) Owner's designated refrigeration equipment manufacturer: Kysor Warren <br />2•) The scheduled data for existing to remain components, circuit loads, and electrical conditions are reproduced from original design documents and may not reflect exact as -built <br />conditions. <br />3•) Contractor shall field verify existing status of data shown for modified racks and notify engineer of any discrepancies. <br />4•) Rack B is subcooled. Refer to OEM submittals for subcooler settings and loads. <br />5•) OEM to ensure adequate size of compressors and condenser to meet 105% NRE at the scheduled ambient temperature conditions above. <br />REFRIG E RAT I O N SCHEDULE SYSTEM RCU -3 <br />Refrig. OEM: <br />Kysor Warren <br />Condenser Type: <br />Air <br />Heat Reclaim Media: <br />Water <br />SG1 Refrig. Liquid Temp (°F): <br />104 <br />SG2 Refrig. Liquid Temp (°F): <br />N/A <br />? SG3 Refrig. Liquid Temp (°F): <br />N/A <br />EXTERIOR DRY BULB (DB) (°F): <br />5 yr. Extreme DB from ASHRAE Pub. <br />96.9 <br />2017 <br />Format: Walmart <br />Store #: 706 <br />System Type: Compressor House <br />Refrigerant: R448a <br />Refrig. BAS: Novar <br />j Sat. Cond. Temp (°F): 112 <br />Heat Reclaim Use: N/A <br />SG1 Comp RGT (°F): 30 <br />SG2 Comp RGT (°F): NIA I SG3 Comp RGT (°F): N/A <br />Proto Size: Cap-X <br />City/State: Zephyrhills, FL <br />Consultant: GPW & Associates <br />Estimated Refrigerant Charge (lbs): N/A <br />System Elec: 208V 3Ph 60Hz <br />Cond. Design TD (°F): 15 <br />Heat Reclaim Water (GPM): _ <br />EXTERIOR WET BULB (WB) (°F): <br />0.4% Monthly Max WB from ASHRAE Pub. <br />81.7 <br />2017 <br />Proto Cycle Date: 1/31/2022 <br />Elevation (ft): p <br />Prepared By: NHA <br />Rack &Cond. Charge (lbs): )p( <br />Defrost Elec: 208V 1 Ph 60Hz <br />Est. Summer THR (MBH): N/A <br />Evap. Superheat (°F): <br />Date Prepared: 2/11/2022 <br />Design DB (°F) / WB (°F): 94.4°F / 81.7°F <br />Interior Design DB (°F) / RH%: <br />75°F / 55% <br />Fixture and Field Piping (lbs): <br />N/A <br />Sys. Pilot Elea <br />208V 1 Ph 60Hz <br />Cond. Elec. <br />208V 1 Ph 6OHz <br />Est. Winter THR Avail (MBH): <br />N/A <br />ASHRAE Design Conditions Weather Station: <br />HERNANDO COUNTY AP, FL <br />CIRCUIT INFORMATION <br />FIXTURE ELECTRICAL <br />INFORMATION <br />CKT # <br />Case Fixture Length / Quantity <br />Walk -In Box Size <br />Case/Coil Model <br />Case/Coil Manuf. <br />Application <br />LSHX Y or N? <br />& Model # <br />WI Evaps <br />Evaporator <br />Coil TXV / <br />Distributor Nozzle <br />Sub -Circuit Load <br />(MBH) <br />Circuit <br />Load (MBH) <br />Evap <br />SST <br />Case/ <br />Walk -In <br />Air Temp <br />Circuit Control Valves <br />Defrost <br />Type <br />Defrost Heaters <br />Fans <br />Lights <br />Amps <br />(120v) <br />Anti -Sweat <br />Amps <br />(120v) <br />Comments <br />Equip Number <br />CKT # <br />FT /# of Doors <br />2 Dr/4' <br />3 Dr/6' <br />4 Dr/8' <br />5 Dr/12' <br />L <br />W <br />H <br />EPR <br />LLSV <br />Amps <br />Voltage <br />Amps Voltage <br />RCU-3 <br />9 <br />18 <br />10 <br />BEL0255BS6EMA <br />BOHN <br />OGP FREEZER <br />SSER-A / L-2 <br />21.7 <br />-18 <br />-10 <br />E5S140 <br />ELEC <br />27.4 <br />208/1 <br />2.5 <br />i 208/1 <br />NEW EVAPORATOR TD 8 DEGREES <br />RCU-3 <br />SUCTION GROUP #1 REQUIRED CAPACITY (MBH): <br />21.7 <br />-21 <br />(°F) Suction Temperature <br />General Notes: <br />1 •) Owner's designated refrigeration equipment manufacturer: Kysor Warren <br />2•) Furnish with oversized receiver. <br />3•) Furnish with time clock for defrost control, installed inside condensing unit. <br />4•) Furnish with thermostat and solenoid for temperature control. <br />5•) OEM to ensure adequate size of compressors and condenser to meet 105% NRE at the scheduled ambient temperature conditions above. <br />PIPING SCHEDULE SYSTEM LTB <br />VERTICAL <br />ESTIMATED <br />i I <br />PIPE <br />HORIZONTAL <br />SUCTION RISER <br />TOTAL <br />DESIGNATION <br />SUCTION <br />AS REQUIRED <br />LIQUID <br />LENGTH AA <br />B 1 <br />1 5/8 <br />1 3/8 <br />1/2 <br />156 <br />B2 <br />1 5/8 <br />1 3/8 <br />1/2 <br />182 <br />B3 <br />t- ---1 <br />--- <br />- <br />- -?---- <br />- <br />64 <br />7/8 <br />5/8 <br />1 1/2 <br />72 <br />B5 <br />j 1 1/8 <br />7/8 <br />1/2 <br />72 <br />B6 <br />' 5/8 <br />1/2 <br />1/2 <br />160 <br />B7 <br />1 1/8 <br />7/8 <br />1/2 <br />} 71 <br />68 <br />1 3/8 <br />1 1/8 <br />1/2 <br />j 120 <br />B9 <br />1 5/8 <br />1 1/8 <br />5/8 <br />j 153 <br />B10 <br />1 3/8 <br />i 7/8 <br />1/2 <br />337 <br />� -- B11 <br />7/8 � <br />- --- <br />---1/2 <br />XXX ----� <br />' B12 <br />1 1/8 <br />7/8 <br />1/2 <br />158 j <br />B13 <br />5/8 <br />112 <br />1/2 <br />180 <br />j <br />{ <br />; <br />! ^ RISER SIZE IS SHOWN EVEN WHERE A RISER IS NOT EXPECTED. THIS IS FOR <br />REFERENCE ONLY AND TO BE USED IN THE EVENT THAT A PIPING CONFLICT CAUSES <br />THE NEED FOR A RISER. IF RISER LENGTH EXCEEDS 4 FEET, IT MUST BE APPROVED <br />I BY ENGINEER OF RECORD. <br />AA ESTIMATED TOTAL LENGTH INCLUDES HORIZONTAL AND VERTICAL PIPE SECTIONS. <br />THIS IS ONLY AN ESTIMATE AND ACTUAL LENGTH WILL VARY. <br />Updated: 02/11/2022 <br />PIPING SCHEDULE SYSTEM RCU-3 <br />VERTICAL <br />ESTIMATED <br />PIPE <br />HORIZONTAL <br />SUCTION RISER <br />TOTAL <br />DESIGNATION <br />SUCTION <br />AS REQUIRED <br />LIQUID <br />LENGTH AA <br />RCU-3 <br />1 3/8 <br />1 3/8 <br />1/2 <br />30 <br />A RISER SIZE IS SHOWN EVEN WHERE A RISER IS NOT EXPECTED. THIS IS FOR <br />REFERENCE ONLY AND TO BE USED IN THE EVENT THAT A PIPING CONFLICT CAUSES <br />THE NEED FOR A RISER. IF RISER LENGTH EXCEEDS 4 FEET, IT MUST BE APPROVED <br />BY ENGINEER OF RECORD. <br />AA ESTIMATED TOTAL LENGTH INCLUDES HORIZONTAL AND VERTICAL PIPE SECTIONS. <br />THIS IS ONLY AN ESTIMATE AND ACTUAL LENGTH WILL VARY. <br />Updated: 03/07/22 <br />U) 11;r <br />� }W p <br />./ - (0 c(V <br />M <br />U00 <br />L0 <br />w LLJ co <br />C) <br />o <br />CO p zwD0 WW <br />W �Zz <br />m az <br />0 li W-WMZF-OOZWm <br />W O <br />ar t- OWPWwUa2acF <br />W=ZU.1rULLLL00 <br />at - AZ <br />.< g-O:51O- <br />wW -< WMwaViZow- <br />] <br />a!2Z<WWOPI>- <br />LL _ �W�arv0a0w0M <br />Z OWitwLLw< <br />O3-aWV50ZZWiz'--Z <br />ZOW29 ,off<zFWF_Za <br />¢<=(L Wt_OLLI <br />O� li <br />d in >. W wTa�yOwOg <br />2 F W a�: M W W O W 0 <br />rnwp,z�H0 OWaMrW <br />��NL)Oria.08W WwaF <br />H <br />Z <br />H <br />J <br />Z <br />O <br />U <br />X <br />a <br />Q <br />U <br />00 <br />CO C_D1L <br />00 <br />U)mj p O <br />J o it <br />0 O <br />n/ Z <br />W <br />O <br />0 � H <br />v �J <br />W <br />N W <br />m <br />D <br />Z <br />I en <br />ISSUE BLOCK <br />CHECKED BY: <br />JKH <br />DRAWN BY: <br />NHA <br />PROTO CYCLE: <br />01/28/22 <br />DOCUMENT DATE: <br />03/17/22 <br />KA Y <br />�p�': ��C•E NSF •�9,y%: <br />No. t4910 j,% <br />STATE OF <br />0 R 11D ' �� <br />I <br />In n F t t 11 WO`04107/2022 <br />by Joanne Hoban <br />'ales LLC, <br />Joannelb E � � 'ng, CN=Joanne <br />n <br />- : t � � ro the accuracy <br />and integ this document. <br />713:10:55-05'00' <br />REFRIGERATION <br />SCHEDULES <br />SHEET: <br />R2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.