Laserfiche WebLink
ELECTRICAL SYMBOLS <br />GENERAL NOTES <br />LEGEND <br />04.24.20 <br />08.28.20 <br />(SYMBOLS APPLY <br />ONLY WHEN USED ON DRAWINGS) <br />1. PERFORM ALL WORK PER NEC AND LOCAL CODES. <br />2. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND <br />LABOR, FOR A COMPLETE INSTALLATION IN ALL RESPECTS, <br />SYMBOL <br />DESCRIPTION <br />LIGHT FIXTURE <br />FO 1/O ❑ <br />(WALL MOUNTED/CEILING MOUNTED) <br />READY FOR INTENDED USE AND IN STRICT ACCORDANCE <br />WITH NEC, NESC, STATE, AND LOCAL CODES, AND <br />O <br />LIGHT FIXTURE <br />MANUFACTURER'S RECOMMENDATIONS. PAY ALL <br />NECESSARY FEES AND PERMITS. <br />A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED <br />ACROSS THE ROOF OR THE EXTERIOR SIDE OF THE <br />LIGHT FIXTURE, <br />NIGHT LIGHT <br />® <br />VOLUMETRIC LIGHT FIXTURE <br />EXTERIOR WALLS. <br />B. ALL EQUIPMENT SHALL BE UL LISTED WHERE <br />APPLICABLE. <br />C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO <br />TRACK LIGHTING <br />STORE OPERATIONS. COORDINATE ALL DISRUPTIONS <br />EXIT FIXTURE <br />/ ® <br />WITH WALMART CONSTRUCTION MANAGER AND STORE <br />(WALL MOUNTED/CEILING MOUNTED) <br />MANAGER. <br />D. CONTRACTOR SHALL VERIFY ALL WALL FINISH <br />/ <br />EMERGENCY LIGHT <br />004 <br />(WALL MOUNTED/CEILING MOUNTED) <br />THICKNESS BEFORE INSTALLING BOXES. FURNISH AND <br />INSTALL EXTENDED BOXES OR BOX EXTENDERS WHERE <br />EMERGENCY LIGHT REMOTE HEADS <br />/ <br />(WALL MOUNTED/CEILING MOUNTED) <br />REQUIRED. <br />E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED <br />PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS <br />$ <br />SINGLE POLE SWITCH <br />PROPERLY COVERED ANDTHAT ALL TRIM IS IN GOOD <br />CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. <br />3. PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: <br />$3 <br />3-WAY SWITCH <br />$4 <br />4-WAY SWITCH <br />A. FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE <br />STOPPING. <br />$K <br />KEYED SWITCH <br />B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. <br />C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM <br />$ D <br />DIMMER SWITCH <br />SEALANT. <br />D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR <br />$ VS <br />VARIABLE SPEED SWITCH <br />SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED <br />DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY <br />$M <br />MANUAL MOTOR SWITCH <br />PENETRATIONS. <br />SINGLE POLE OCCUPANCY <br />OS <br />SENSOR SWITCH <br />4. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR <br />(SIZE PER NEC) IN PVC TYPE CONDUIT, POWER AND LIGHTING <br />$OS2 <br />DOUBLE POLE OCCUPANCY <br />CIRCUITS, ISOLATED GROUND CIRCUITS, OR AS SHOWN ON <br />SENSOR SWITCH <br />PLANS. CONDUIT SHALL BE SIZED PER NEC BASED ON THWN <br />600 VOLT COPPER SINGLE CONDUCTORS, PLUS THE <br />CEILING MOUNTED OCCUPANCY <br />(66S 4 <br />SENSOR SWITCH, FOUR -DIRECTION <br />EQUIPMENT GROUNDING CONDUCTOR. <br />SENSING <br />5. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM <br />WALL MOUNTED OCCUPANCY SENSOR <br />FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS <br />OS <br />SWITCH, ONE -DIRECTION SENSING <br />NOTED OTHERWISE ON PLANS. COORDINATE THE <br />STANDARD MOUNTING HEIGHTS WITH MASONRY: <br />A. SWITCHES +44" <br />RECEPTACLE, DUPLEX <br />B. RECEPTACLES +20" <br />C. VOICE/DATA +20" <br />RECEPTACLE, DUPLEX, <br />MOUNTED HORIZONTALLY <br />6. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL <br />EQUIPMENT IN CONFORMANCE WITH EQUIPMENT SUPPLIER <br />RECEPTACLE, GFI <br />WIRING DIAGRAMS. <br />7. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AN UPDATED <br />RECEPTACLE, DUPLEX FLUSH FLOOR <br />AND COMPLETE TYPEWRITTEN CIRCUIT IDENTIFICATION <br />RECEPTACLE, DUPLEX ISOLATED <br />SCHEDULE FOR EVERY PANELBOARD AFFECTED BY THIS <br />GROUND FLUSH FLOOR <br />PROJECT. <br />8. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN <br />RECEPTACLE, DOUBLE DUPLEX <br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL <br />x <br />RECEPTACLE, DUPLEX <br />MATCH THE TYPE AND AIC RATING OF EXISTING <br />ll <br />ISOLATED GROUND <br />OVERCURRENT PROTECTIVE DEVICES. <br />9. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG <br />RECEPTACLE, DOUBLE DUPLEX, <br />ISOLATED GROUND <br />UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A <br />BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, # <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />L5-15R, LINO <br />10 AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION <br />(15-FT MAXIMUM). <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />ISOLATED GROUND, L5-15R, LINO <br />10. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />AND DERATE CURRENT CARRYING CONDUCTORS PER NEC. <br />L5-15R, LINO <br />11. PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />ISOLATED GROUND, L5-15R, UNO <br />BRANCH CIRCUITS PER NEC REQUIREMENTS. <br />12. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY <br />& <br />RECEPTACLE, SPECIAL <br />TYPE SHALL BE MADE TO BRIDGING OR JOIST WEB <br />MEMBERS. UTILIZE ONLY THE TOP AND BOTTOM CHORDS <br />RECEPTACLE, SIMPLEX <br />FOR SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. <br />13. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE <br />RECEPTACLE, PLUG -MOLD <br />SURFACE MOUNTED UNLESS NOTED OTHERWISE. SEAL <br />DEVICES TO COOLER/FREEZER PANELS WITH SILICONE <br />O <br />JUNCTION BOX <br />(WALL MOUNTED/CEILING MOUNTED) <br />SEALANT. <br />14. SURFACE MOUNTED CONDUIT ON COOLER/FREEZER PANELS <br />O <br />THERMOSTAT <br />(WALL MOUNTED/CEILING MOUNTED) <br />OR IN FOOD PREP AREAS SHALL BE INSTALLED WITH <br />GALVANIZED 1/2" STANDOFF CONDUIT HANGERS TO ALLOW <br />O <br />ALARM JUNCTION BOX, <br />(WALL MOUNTED/CEILING MOUNTED) <br />FOR CLEANING. <br />15. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM <br />ALARM JUNCTION BOX, <br />® <br />FOR REMOTE TEST/RESET <br />AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE <br />(WALL MOUNTED/CEILING MOUNTED) <br />INSTALLED UNDER SLAB, PROVIDE EXTERIOR COATED GRC <br />BENDS ON ALL CONDUIT RUNS THAT HAVE 45 DEGREE <br />SMOKE DETECTOR <br />BENDS OR GREATER. REFER TO SPECIFICATION SECTION <br />16.100 FOR UNDER SLAB. <br />Eh <br />NON -FUSED DISCONNECT <br />16. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION <br />COUPLINGS AND BRACING FOR ELECTRICAL EQUIPMENT AS <br />01 <br />FUSED DISCONNECT <br />REQUIRED BY LOCAL CODES. <br />17. EXISTING ELECTRICAL AND ALARM: <br />O <br />EQUIPMENT CONNECTION POINT <br />(PROVIDED WITH EQUIPMENT) <br />A. WHERE DEMOLITION OR NEW CONSTRUCTION <br />INTERRUPTS EXISTING ELECTRICAL CIRCUITS FEEDING <br />CIRCUIT, CONCEALED IN WALLS OR <br />CEILING, E INDICATES EXISTING WIRING <br />EXISTING EQUIPMENT, DEVICES, OR LIGHTING TO <br />REMAIN, BUT NOT SHOWN ON DRAWINGS, PROVIDE <br />�- <br />CIRCUIT, CONCEALED IN SLAB FLOOR, <br />LABOR AND MATERIALS TO REWORK CIRCUITRY, AS <br />E INDICATES EXISTING WIRING <br />REQUIRED, TO MAINTAIN EXISTING OPERATION. <br />B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT <br />CIRCUIT, EXPOSED, <br />E INDICATES EXISTING WIRING <br />EXISTING UNDERGROUND SERVICES (ELECTRICAL, <br />TELEPHONE, PARKING LOTLIGHTING CIRCUITRY, ETC.) <br />-�----------- <br />LOW VOLTAGE WIRING <br />PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO <br />REROUTE, SLEEVE, OR OTHERWISE REWORK THESE <br />SERVICES TO MAINTAIN THEIR EXISTING OPERATION. <br />I -I <br />CONDUIT SLEEVE <br />C. EXERCISE CAUTION AROUND ALARM AND SECURITY <br />CABLES DURING DEMOLITION AND CONSTRUCTION. <br />= <br />FLUSH MOUNTED PANELBOARD <br />PROTECT ALARM AND SECURITY CABLES FROM <br />ACCIDENTAL DAMAGE SO THAT SYSTEMS REMAIN <br />OPERATIONAL AT ALL TIMES. <br />SURFACE MOUNTED PANELBOARD <br />D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS <br />OTHERWISE NOTED. <br />- <br />TELEPHONE /DATA BOX FOR ISD <br />18. EXISTING ELECTRICAL DEMOLITION: <br />17 <br />LOW VOLTAGE CABLE <br />A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL <br />BOX FOR OTHER <br />EQUIPMENT, CONDUIT AND CONDUCTORS AS INDICATED <br />ON THE DRAWINGS, OR ONLY AS REQUIRED BY <br />It <br />TELEPHONE, FLUSH FLOOR <br />DEMOLITION. REMOVE ALL PANELBOARDS, DISCONNECT <br />SWITCHES, BOXES, RELAYS, TIME SWITCHES, LIGHTS, <br />DEVICES, ETC., WHICH WILL NOT BE REUSED. <br />MOTOR <br />000/// <br />B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, <br />CONDUCTORS AND RELATED DEVICES SERVING SALES <br />TELEPOWER POLE <br />AREA GONDOLAS BEING RELOCATED OR REMOVED. <br />EXISTING CONDUIT AND CONDUCTORS MAY BE REUSED <br />Y <br />PUSH BUTTON <br />FOR NEW POWER DROPS WHERE SIZE, RATING, AND <br />CONDITION MEET REQUIREMENTS INDICATED ON PLANS <br />AND ALL U.L. RATINGS. REMOVE ALL UNUSED CONDUIT <br />B� <br />BUZZER <br />AND CONDUCTORS BACK TO POINT OF ORIGIN <br />WHENEVER FEASIBLE. IF CIRCUIT IS NOT REUSED, <br />REMOVE CIRCUIT BREAKER AND REPLACE WITH FILLER <br />SS <br />SAIL SWITCH <br />JUNCTION BOX <br />PLATE. EXCEPTION: DISTRIBUTION AND POWER SWITCH <br />BREAKERS SHALL BE ETR AS "SPARE". PROVIDE HANDLE <br />t`�JK�I <br />HORN/STROBE <br />LOCK OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN <br />THE "OFF" POSITION. UPDATE TYPEWRITTEN CIRCUIT <br />DH <br />DOOR HOLD OPEN <br />IDENTIFICATION SCHEDULE AS "SPACE" OR "SPARE". <br />C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING <br />SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH <br />FTC] <br />TIME CLOCK <br />STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE <br />FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE. <br />ABBREVIATIONS <br />CONDUIT TO BE ABANDONED IN WALLS OR FLOORS <br />SHALL BE REMOVED BACK TO FINISHED SURFACE AND <br />a, b, c LOWER CASE <br />LETTERS INDICATE <br />CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH <br />SWITCHING <br />CONFIGURATION <br />ADJACENT. <br />AFF ABOVE FINISHED <br />FLOOR <br />D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO <br />AFG ABOVE FINISHED <br />GRADE <br />BE REMOVED SHALL ALSO BE REMOVED. REMOVE <br />C CONDUIT <br />CIRCUIT BREAKER AND REPLACE WITH FILLER PLATE. <br />CCT CIRCUIT <br />EXCEPTION: DISTRIBUTION AND POWER SWITCH <br />CF COIL FAN <br />BREAKERS SHALL BE ETR AS "SPARE". PROVIDE HANDLE <br />CW CASH WRAP <br />LOCK OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN <br />EC ELECTRICAL <br />CONTRACTOR <br />THE "OFF" POSITION. UPDATE TYPEWRITTEN CIRCUIT <br />ED ELECTRIC <br />DEFROST <br />IDENTIFICATION SCHEDULE AS "SPACE" OR "SPARE". <br />EF EXHAUST <br />FAN <br />E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO <br />ETR EXISTING <br />TO REMAIN <br />SELECTIVE SITE DEMOLITION SPECIFICATION FOR <br />EWC ELECTRIC <br />WATER COOLER <br />DISPOSAL OF LIGHT FIXTURE. <br />G GROUND <br />F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF <br />GC GENERAL <br />CONTRACTOR <br />WORK SHALL BE SECURED TO PREVENT FALLING, <br />GFEP GROUND FAULT <br />EQUIPMENT PROTECTION <br />LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE <br />GFI GROUND FAULT <br />CIRCUIT INTERRUPTER <br />FUTURE. <br />HD HAND DRYER <br />IG ISOLATED <br />GROUND <br />19. DATA AND PHONE CONDUIT INSTALLATION MILESTONE DATE: <br />LCU LIGHTING <br />CONTROL UNIT <br />ALL RACEWAY AND CONDUIT SLEEVES FOR DATA AND <br />MCB MAIN CIRCUIT <br />BREAKER <br />PHONE CABLING TO BE INSTALLED 3 WEEKS PRIOR TO <br />MLO MAIN LUG <br />ONLY <br />CONTRACT SUBSTANTIAL COMPLETION DATE. <br />NTS NOT TO SCALE <br />RC REFRIGERATION <br />CONTRACTOR <br />20. ETHERNET CABLE: <br />RH RADIANT HEATER <br />A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON <br />SC SECURITY <br />CAMERA <br />PLANS. PROVIDE CONDUIT AS REQUIRED BY LOCAL <br />TYP TYPICAL <br />CODES AND/OR ORDINANCES. <br />UH UNIT HEATER <br />B. ETHERNET CABLE IS FURNISHED BY OTHERS. <br />UNO UNLESS NOTED <br />OTHERWISE <br />C. ELECTRICAL CONTRACTOR SHALL INSTALL CABLE IN <br />WH WATER HEATER <br />POWER POLES. <br />WP(I) WEATHER <br />PROOF (1) WHILE -IN -USE <br />D. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE <br />WR WEATHER <br />RESISTANT <br />AS DIRECTED BY WALMART CONSTRUCTION MANAGER. <br />H 1 131 PA N E L B OA R D 277/480 V, 30, 4W <br />800 A, MLO <br />FED FROM MSB1: 800A SW EXISTING <br />LOCATION: EDC1 <br />SERVES: 480V DISTRIBUTION SURFACE <br />CKT <br />DESCRIPTION <br />WIRE <br />BRKR <br />PL <br />[KVA] <br />[KVA] <br />[C <br />PL <br />BRKR <br />WIRE <br />DESCRIPTION <br />CKT <br />1 <br />28.24 20.06 <br />2 <br />3 <br />AHU-2 (2,23) ## <br />1 <br />125 <br />3 <br />28.24 1 17.68 <br />3 <br />125 <br />-- <br />transformer tl d (13) <br />4 <br />5 <br />1 28.24 1 20.98 <br />28.24 38.04 <br />6 <br />7 <br />8 <br />9 <br />AHU-3 (2,23) ## <br />1 <br />125 <br />3 <br />1 28.24 39.77 <br />3 <br />200 <br />- <br />panel h1 pl (13) <br />10 <br />11 <br />1 28.24 39.33 <br />2.22 32.92 1 <br />12 <br />13 <br />14 <br />15 <br />mg3 battery chargers (13) <br />-- <br />20 <br />3 <br />1 2.22 32.81 <br />3 <br />200 <br />-- <br />panel hlp2 (13) <br />16 <br />17 <br />L 2.22 29.61 <br />3.88 36.34 <br />18 <br />19 <br />20 <br />21 <br />mg5 compactor (13) <br />-- <br />30 <br />3 <br />L3.88 37.34 1 <br />3 <br />200 <br />- <br />panel h2b (13) <br />22 <br />23 <br />1 3.88 1 33.47 <br />3.88 8.87 <br />3.88 9.03 -- <br />24 <br />25 <br />27 <br />mg4 baler (13) <br />-- <br />30 <br />3 <br />2 <br />70 <br />-- <br />transformer tpl (13) <br />26 <br />28 <br />29 <br />1 3.88 1 0.00 <br />3-88 0.00 1 <br />30 <br />-- <br />-- <br />-- <br />space <br />31 <br />space <br />32 <br />-- <br />-- <br />- <br />space <br />33 <br />mg4 baler (13) <br />-- <br />30 <br />3 <br />1 3.88 0.00 <br />34 <br />-- <br />-- <br />- <br />space <br />35 <br />1 3.88 1 0.00 <br />0.00 1 <br />36 <br />37 <br />space <br />38 <br />-- <br />-- <br />-- <br />space <br />39 <br />0.00 <br />40 <br />-- <br />-- <br />-- <br />space <br />41 <br />1 0.00 <br />42 <br />TOTAL CONNECTED 206.57 206.97 193.73 KVA <br />TOTAL CONNECTED 763 754 699 AMPS <br />TOTAL LOAD 607.26 KVA 730 AMPS <br />PER NEC ARTICLE 220: FEEDER LOAD 519.70 KVA 625 AMPS <br />## FIELD VERIFY WIRE SIZE. IF #1 AWG PROVIDE HACR BREAKER AS SHOWN. IF #1/0 OR GREATER THEN EXISTING 150A BREAKER TO REMAIN. <br />1­14 B PANELBOARD 277/480 V, 30, 4W <br />600 A, MLO <br />EXISTING <br />LOCATION: EDC4 <br />SERVES: 480V DISTRIBUTION SURFACE <br />CKT <br />DESCRIPTION <br />WIRE <br />BRKR <br />PL <br />[KVA] <br />[KVA] <br />(KVAJ <br />PL <br />BRKR <br />WIRE <br />DESCRIPTION <br />CKT <br />1 <br />45.85 2.49 <br />2 <br />3 <br />xfmr t4d (13) <br />-- <br />225 <br />3 <br />49.24 2.49 <br />3 <br />20 <br />-- <br />b123 wash sink (13) <br />4 <br />5 <br />1 1 50.62 1 2.49 <br />24.13 9.72 <br />1 <br />6 <br />7 <br />8 <br />9 <br />xfmr tfs (13) <br />- <br />125 <br />3 <br />27.48 9.72 <br />3 <br />50 <br />-- <br />air door #1 (13) <br />10 <br />11 <br />1 30.25 1 .72 <br />28.24 9.17 <br />1 <br />12 <br />13 <br />14 <br />15 <br />AHU-1 (2,23) ## <br />1 <br />125 <br />3 <br />28.24 9.17 <br />3 <br />40 <br />- <br />fryer <br />16 <br />shun <br />shunt trip breaker <br />17 <br />28.24 9.17 <br />3.88 1 9.17 1 <br />18 <br />19 <br />20 <br />21 <br />mg5 compactor (13) <br />-- <br />30 <br />3 <br />0.00 9.17 <br />3 <br />60 <br />- <br />fryer <br />22 <br />shun <br />shunt trip breaker <br />23 <br />0.00 9.17 <br />0.00 J9.17 <br />24 <br />25 <br />space <br />-- <br />- <br />-- <br />fryer <br />26 <br />space <br />-- <br />-- <br />- <br />27 <br />0.00 9.17 <br />3 <br />60 <br />- <br />shunt <br />shunt trip breaker <br />s <br />28 <br />space <br />-- <br />-- <br />-- <br />29 <br />0.00 9.17 <br />3.60 7.69 <br />30 <br />31 <br />32 <br />33 <br />PU FRZR HAC DOOR (2) <br />12 <br />20 <br />3 <br />L 3.60 1 9.05 <br />3 <br />60 <br />-- <br />pnlbd h4c (13) <br />34 <br />35 <br />3.60 6.84 <br />36 <br />TOTAL CONNECTED 153.11 157.33 159.27 KVA <br />TOTAL CONNECTED 553 570 577 AMPS <br />TOTAL LOAD 469.71 KVA 565 AMPS <br />PER NEC ARTICLE 220: FEEDER LOAD 394.88 KVA 475 AMPS <br />## FIELD VERIFY WIRE SIZE. IF #1 AWG PROVIDE HACR BREAKER AS SHOWN. IF #1/0 OR GREATER THEN EXISTING 150A BREAKER TO REMAIN. <br />L4 D 1 <br />PANELBOARD <br />120/208 V, 30, 4W <br />100 A, MCB <br />EXISTING <br />1AIC <br />GROUUNDND BUS <br />LOCATION: EDC4 <br />ISOLATED <br />GROUND BAR <br />SERVES: GROCERY MISC POWER <br />SURFACE <br />CKT <br />DESCRIPTION <br />WIRE <br />BRKR <br />PL <br />[KVA] <br />[KVAJ <br />[ C <br />PL <br />BRKR <br />WIRE <br />DESCRIPTION <br />CKT <br />1 <br />0.94 4.26 <br />2 <br />3 <br />m25 meat saw (13) <br />-- <br />20 <br />3 <br />0.94 1 4.26 <br />3 <br />60 <br />6 <br />RCU-3 (2,23) <br />4 <br />5 <br />1 <br />0.87 1 0.00 <br />1 0.94 1 <br />4.26 <br />6 <br />7 <br />m2 slicer (13) <br />-- <br />20 <br />1 <br />8 <br />9 <br />1 1.18 0.00 <br />3 <br />20 <br />-- <br />SPARE (24) was seafood <br />disposal <br />10 <br />m4 cuber/tenderizer(13) <br />-- <br />20 <br />1 <br />11 <br />0.90 1 0.00 <br />1.48 <br />0.00 <br />12 <br />p2 wrapper (13) <br />-- <br />20 <br />1 <br />13 <br />pickup outlets (13) <br />-- <br />20 <br />1 <br />2 <br />20 <br />-- <br />p16 ice flaker (13) <br />14 <br />UNKNOWN LOAD (22) <br />-- <br />20 <br />1 <br />15 <br />0.14 0.14 <br />16 <br />17 <br />1.05 0.72 <br />1 0.50 <br />0.06 <br />18 <br />UNKNOWN LOAD (22) <br />- <br />20 <br />1 <br />1 <br />20 <br />12 <br />EDC4 BAS CONTROLS (3,19) <br />19 <br />ogp cooler (13) <br />-- <br />20 <br />2 <br />1 <br />20 <br />- <br />manager station (13) <br />20 <br />1 <br />20 <br />-- <br />p13b repress (13) <br />21 <br />1 1.05 1 0.80 <br />22 <br />jogpco,oler (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />pl3c equipment (13) <br />23 <br />4.00 0.77 <br />1 0.68 T <br />1.04 <br />24 <br />25 <br />flower cooler (13) <br />-- <br />50 <br />2 <br />1 <br />20 <br />-- <br />self checkout / coolers (13) <br />26 <br />1 <br />1 <br />20 <br />-- <br />self checkout (13) <br />27 <br />4.00 0.26 <br />28 <br />29 <br />self checkout / cooler 13 <br />-- <br />20 <br />1 <br />0.92 <br />0.34 <br />1 <br />1 <br />20 <br />-- <br />ogp cooler 13 <br />30 <br />TOTAL CONNECTED <br />13.51 <br />12.78 <br />10.22 <br />KVA <br />TOTAL CONNECTED <br />116 <br />110 <br />85 <br />AMPS <br />TOTAL LOAD <br />36.51 <br />KVA <br />101 <br />AMPS <br />PER NEC ARTICLE 220: <br />FEEDER LOAD <br />29.86 IKVA <br />83 <br />IAMPS <br />L4D2 <br />FED FROM 150KVA T413 <br />LOCATION: EDC4 <br />SERVES: GROCERY MISC POWER <br />PANELBOARD <br />EXISTING <br />120/208 V, 30, 4W <br />100 A, MCB <br />10,000 AIC <br />GROUND BUS <br />ISOLATED GROUND BAR <br />SURFACE <br />CKT <br />DESCRIPTION <br />WIRE <br />BRKR <br />PL <br />[KVA] <br />[KVA] <br />[KVA] <br />PL <br />BRKR <br />WIRE <br />DESCRIPTION <br />CKT <br />1 <br />3 <br />5 <br />coffee grinder (13) <br />- <br />20 <br />1 <br />0.96 0.18 <br />0.72 0.30 <br />0.51 0.54 1 <br />0.60 0.54 <br />1 <br />1.08 0.90 1 <br />1.26 1 1.14 <br />1 1.08 1.08 <br />0.60 1 0.54 <br />0.30 1 0.54 1 <br />1 <br />L 0.54 1 1.26 <br />1.44 1 0.50 <br />1.16 0.54 <br />1 0.60 1.02 <br />0.10 1 0.80 <br />0.54 1 0.26 <br />1 <br />20 <br />-- <br />edc4 outlets (13) <br />2 <br />4 <br />6 <br />column outlets (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />m18 hand wrap (13) <br />column outlets (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />b26 & d4 scales (13) <br />7 <br />9 <br />11 <br />groc doc outlets (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />p12 & s13 scales (13) <br />8 <br />10 <br />12 <br />groc doc outlets (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />stockroom outlets (13) <br />grocery frzr Its (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />UNKNOWN LOAD (22) <br />13 <br />15 <br />17 <br />ice cream frzr Its (13) <br />- <br />20 <br />1 <br />1 <br />20 <br />-- <br />UNKNOWN LOAD (22) <br />14 <br />16 <br />18 <br />Igrocery frzr htrs (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />UNKNOWN LOAD (22) <br />1 ice cream frzr htrs (13) <br />-- <br />20 <br />11 <br />1 <br />20 <br />-- <br />d11 fans/Its (13) <br />19 <br />21 <br />23 <br />meat/deli clr htrs (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />UNKNOWN LOAD 22) <br />20 <br />22 <br />24 <br />meat holding htrs (13) <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />UNKNOWN LOAD (22) <br />PU FRZR LIGHTS (19) <br />12 <br />20 <br />1 <br />1 <br />20 <br />-- <br />printers (13) <br />25 <br />27 <br />29 <br />AHU-1,2/RTUs 13-15,21 RCPTS (6,19) <br />6 <br />20 <br />1 <br />1 <br />20 <br />12 <br />PU FRZR DR & COND HTRS (2,5) <br />26 <br />28 <br />30 <br />UNKNOWN LOAD (22) <br />-- <br />20 <br />1 <br />1 <br />20 <br />1-- <br />sco / cooler (13) <br />UNKNOWN LOAD 22 <br />-- <br />20 <br />1 <br />1 <br />20 <br />-- <br />sco 13 <br />TOTAL CONNECTED <br />TOTAL CONNECTED <br />TOTAL LOAD <br />PER NEC ARTICLE 220: FEEDER LOAD <br />6.33 <br />53 <br />21.57 <br />17.70 <br />8.28 <br />70 <br />KVA j <br />KVA <br />6.96 <br />59 <br />60 <br />49 <br />KVA <br />AMPS <br />AMPS <br />AMPS <br />BUILDING ELECTRICAL SERVICE LOAD SUMMARY <br />BUILDING OCCUPANCY TYPE: M <br />BUILDING SQUARE FOOTAGE: 208,043 <br />SERVICE DESCRIPTION: <br />480Y/277V, 3PH <br />LOAD DESCRIPTION <br />CONNECTED <br />DEMAND I <br />DEMAND <br />KVA <br />FACTOR <br />KVA <br />EXISTING PEAK UTILITY LOAD @ 0.90 PF <br />N/Al <br />100% <br />946.67 <br />NEW LOAD TO BE ADDED <br />272.7500 <br />0 <br />/ 1 0 <br />272.75 <br />EXISTING LOAD TO BE REMOVED <br />O <br />(225.34) <br />0 <br />100 /o <br />(225.34) <br />TOTAL APPARENT -POWER LOAD <br />KVA <br />994.08 <br />TOTAL CURRENT LOAD <br />AMPS <br />1195.69 <br />UTILITY SERVICE AMPACITY - 1500 KVA <br />AMPS <br />1804.27 <br />SPARE CAPACITY <br />AMPS <br />608.58 <br />*PER UTILITY COMPANY BILLING PEAK DEMAND OF: 852 KW JUL-21 <br />COORDINATE ALL CHANGES TO EXISTING ELECTRICAL <br />SERVICE AND METERING WITH UTILITY COMPANY. <br />STORE ADDRESS: WALMART SC STORE #0706 <br />7631 GALL BLVD <br />ZEPHYR HILLS, FL 33541 <br />UTILITY COMPANY: DUKE ENERGY <br />CONTACT: CIRAY OVERHOZLER <br />Ciray.Overholzer@duke-energy.com <br />PHONE: 980-373-2562 <br />EXISTING <br />UTILITY TRANSFORMER <br />L-� 480Y/277V, 30, 4W SEC <br />THIS ONE -LINE IS SHOWN FOR INFORMATIONAL <br />PURPOSES ONLY AND ANY NEW DEVICES ARE <br />SHOWN IN BOLD AND ARE NOTED. <br />IF IT IS NECESSARY TO REMOVE A METER, RTU <br />SERVER, CT OR DISRUPT THE COMMUNICATION OF THE <br />SYSTEM, THE CONTRACTOR IS RESPONSIBLE TO <br />RESTORE THE SYSTEM TO THE SAME LEVEL OF <br />OPERATION THAT EXISTED PRIOR TO THE WORK BEING <br />INITIATED. THE EXISTENCE AND FUNCTIONALITY OF THE <br />SYSTEM SHALL BE VERIFIED BY CALL WALMART <br />BUILDING PERFORMANCE TEAM AT 479-204-0432 <br />BETWEEN THE HOURS OF 7 AM UNTIL 5 PM CT. <br />MSB1 EXISTING <br />I I <br />4000 AMPS 277/480V 30 4W <br />I <br />C600A 800A 600A 600A 600A <br />3P C 3P ( 3P 3P C 3P <br />ETR ETR ETR ETR ETR <br />I <br />I I I <br />H1A <br />EXISTING <br />PNLBD <br />H1B1 <br />277/480V <br />F_ - <br />I <br />I <br />T1 D I <br />75VA I EXISTING <br />120/208V PNLBD <br />(EXISTING) I H413 <br />I <br />277/480V <br />T <br />.1- I <br />COMPRESSOR I <br />HOUSE #2 I <br />I <br />I <br />I I I <br />I I EXISTING <br />CH1 <br />MAIN <br />480V <br />EXISTING <br />PNLBD I <br />T4D I I <br />L1 D I <br />150VA 1 <br />120/208V <br />48OV- <br />I <br />I <br />208Y/120V I I = <br />I = <br />(EXISTING) <br />I I <br />ELECTRICAL ROOM 1 <br />- - - - I <br />1 I <br />TCH1 <br />150KVA <br />480V- <br />208Y/120V <br />(EXISTING) <br />I <br />I <br />EXISTING <br />PNLBD <br />I EXISTING EXISTING I I 208V SDP <br />I PNLBD PNLBD I I 120/208V <br />L4D1 L4D2 <br />120/208V 120/208V <br />I I I I <br />I I I COMPRESSOR <br />ELECTRICAL ROOM 4 HOUSE #1 <br />PARTIAL ONE -LINE DIAGRAM <br />NTS <br />POWER INTERRUPTION NOTE <br />11.30.18 <br />COORDINATE ALL WORK THAT REQUIRES POWER <br />INTERRUPTIONS TO THE STORE WITH THE STORE <br />MANAGER AND THE WALMART CONSTRUCTION MANAGER <br />A MINIMUM OF 48 HOURS IN ADVANCE OF ALL STORE <br />POWER INTERRUPTIONS. IN ADDITION, IF THE MAIN <br />ELECTRICAL SWITCHGEAR REQUIRES WORK AND DOES <br />NOT HAVE A MAIN SERVICE DISCONNECTING MEANS, <br />COORDINATE WITH THE UTILITY COMPANY A MINIMUM OF <br />TWO WEEKS IN ADVANCE OF THE STORE POWER <br />INTERRUPTION. IF STORE IS NOT OPEN 24 HOURS PER <br />DAY, ALL STORE POWER INTERRUPTIONS ARE TO BE <br />ACCOMPLISHED AFTER NORMAL STORE BUSINESS <br />HOURS. PROVIDE TEMPORARY POWER AS REQUIRED <br />PER SPECIFICATIONS. INSTALLATION OF NEW EQUIPMENT <br />SHALL BE COMPLETED AND THE POWER SYSTEM TESTED <br />AND RE -ENERGIZED PRIOR TO THE TIME ESTABLISHED BY <br />THE STORE MANAGER AND THE WALMART <br />CONSTRUCTION MANAGER. <br />ONE -LINE DIAGRAM LEGEND <br />11.19.10 <br />NEW EQUIPMENT <br />EXISTING EQUIPMENT <br />- - - - - EQUIPMENT TO BE DEMOLISHED, UNO <br />NOTE: <br />ALL OF THE ELECTRICAL DEVICES SHOWN ON THE RISER <br />DIAGRAM ARE EXISTING AND ARE BASED UPON AS -BUILT <br />DRAWINGS. E.C. SHALL VERIFY THE EXACT EXISTING <br />CONDITIONS, SIZES AND LOCATIONS OF EQUIPMENT <br />PRIOR TO ROUGH -IN. THIS RISER IS SHOWN FOR <br />INFORMATIONAL PURPOSES ONLY AND ANY NEW <br />DEVICES ARE SHOWN IN BOLD AND ARE NOTED. DURING <br />CONSTRUCTION, THE STORE SHALL STAY OPEN FOR <br />BUSINESS. ANY NECESSARY POWER DOWNTIME SHALL <br />BE SCHEDULED AND APPROVED BY WALMART <br />CONSTRUCTION MANAGER. <br />9 10 11 12 <br />z <br />E2 <br />4) 2 r4 55 11 rl3j 5D <br />PANELBOARD NOTES () <br />08.28.20 <br />1. TERMINATE GROUND ON ISOLATED GROUND BUS. <br />2. INSTALL LOCKING DEVICE (LOCK -OFF FOR <br />MAINTENANCE). LOCKING DEVICE SHALL BE UL <br />LISTED. MANUFACTURER SHALL MATCH EXISTING <br />PANELBOARD MANUFACTURER. <br />3. INSTALL LOCKING DEVICE (LOCK -ON FOR CRITICAL <br />LOAD). <br />4. GFI BREAKER FOR PERSONNEL PROTECTION (5MA). <br />5. GFI BREAKER FOR EQUIPMENT PROTECTION (30MA). <br />6. CONDUCTOR SIZE HAS BEEN INCREASED FOR <br />VOLTAGE DROP. SIZE EQUIPMENT GROUNDING <br />CONDUCTOR PROPORTIONATELY PER NEC. <br />7. REFER TO ONE -LINE DIAGRAM FOR AVAILABLE FAULT <br />CURRENT FOR INTERRUPT RATINGS. <br />8. REFER TO ONE -LINE DIAGRAMS FOR WIRE SIZES. <br />9. FACTORY WIRED TO LOAD. <br />10. BREAKER SHALL BE HIGH MAGNETIC TYPE. <br />11. BREAKER REMOVAL - FIELD VERIFY CIRCUIT <br />BREAKER IS NOT SERVING AN EXISTING LOAD. IF NO <br />EXISTING LOAD, REMOVE CIRCUIT BREAKER AND <br />PROVIDE FILLER PLATE. IF BREAKER IS SERVING A <br />LOAD, IDENTIFY LOAD SERVED. UPDATE CIRCUIT <br />IDENTIFICATION SCHEDULE AS "SPACE" OR INDICATE <br />LOAD SERVED. <br />12. DUAL TAP SOLENOID OPERATED BREAKER. CONNECT <br />EMERGENCY/NIGHT LIGHTING TO UNSWITCHED <br />TERMINATION. <br />13. EXISTING CIRCUIT AND/OR CIRCUIT BREAKER. <br />14. ROUTE CIRCUIT THROUGH CONTACTOR. <br />15. PROVIDE INTERLOCK WIRING WITH EXHAUST HOOD <br />ANSUL SYSTEM. <br />16. RELOCATED CIRCUIT FROM EXISTING PANELBOARD, <br />17. PROVIDE BLANK CIRCUIT BREAKER FILLER PLATE <br />FOR EXPOSED SPACE IN PANELBOARD. <br />18, PROVIDE U.L. LISTED OVERCURRENT DEVICE TO <br />COORDINATE AND MAINTAIN MANUFACTURER'S <br />SERIES RATED SYSTEM. <br />19. EXISTING CIRCUIT BREAKER TO REMAIN. VERIFY <br />CONDITION OF CIRCUIT BREAKER TO ENSURE THAT IT <br />IS OPERATIONAL AND MEETS ALL U.L. RATINGS. <br />20. ROUTE CIRCUIT THROUGH EXISTING LCU CABINET <br />UTILIZING EXISTING RELAY AND CONTROLS. UPDATE <br />LCU IDENTIFICATION SCHEDULE WITH LOAD <br />IDENTIFICATION. <br />21. REMOTELY OPERATED CIRCUIT BREAKER. REFER TO <br />ENERGY MANAGEMENT PLANS FOR CIRCUIT <br />BREAKER CONTROL. <br />22. EXISTING LOAD - TRACE EXISTING CIRCUIT, IDENTIFY <br />LOAD AND UPDATE CIRCUIT IDENTIFICATION <br />SCHEDULE FOR LOAD SERVED. IF CIRCUIT IS NOT IN <br />USE, REFER TO PANELBOARD NOTE (11). <br />23. HACR TYPE CIRCUIT BREAKER. <br />24. SPARE - FIELD VERIFY CIRCUIT BREAKER IS NOT <br />SERVING AN EXISTING LOAD. IF NO EXISTING LOAD, <br />PROVIDE LOCK OFF DEVICE TO LOCK SPARE <br />BREAKER IN THE OFF POSITION. IF BREAKER IS <br />SERVING A LOAD, IDENTIFY LOAD SERVED. UPDATE <br />CIRCUIT IDENTIFICATION SCHEDULE AS "SPARE" OR <br />INDICATE LOAD SERVED, <br />25. EXISTING LOAD - TRACE EXISTING CIRCUIT, IDENTIFY <br />LOAD AND UPDATE CIRCUIT IDENTIFICATION <br />SCHEDULE FOR LOAD SERVED. IF CIRCUIT IS NOT IN <br />USE, REFER TO PANELBOARD NOTE (24). <br />26. ROUTE CIRCUIT THROUGH ENCLOSED GFI BREAKER <br />FOR PERSONNEL PROTECTION (5MA). <br />GENERAL NOTES: <br />1. NEW OVERCURRENT PROTECTIVE DEVICES PLACE IN <br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS <br />SHALL MATCH THE TYPE AND AIC RATING OF <br />EXISTING OVERCURRENT PROTECTION DEVICES IN <br />SAID BOARD. <br />2. E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR <br />EVERY EXISTING PANELBOARD AFFECTED BY THIS <br />PROJECT. IDENTIFY LOADS ON EACH CIRCUIT. <br />PROVIDE A COMPLETE TYPEWRITTEN CIRCUIT <br />IDENTIFICATION SCHEDULE FOR EVERY AFFECTED <br />PANELBOARD. <br />3. ALL OVERCURRENT DEVICES ARE NEW UNLESS <br />NOTED OTHERWISE. <br />20A WIRE SIZING SCHEDULE <br />ALL WIRE SIZES SHOWN ON PANEL SCHEDULES ARE <br />INTENDED TO BE MINIMUM ACCEPTABLE WIRE SIZE. <br />THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE <br />WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). <br />LENGTHS (IN FEET) ARE INTENDED TO BE MAXIMUM. <br />120 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />200 FT. <br />325 FT. <br />490 FT. <br />770 FT. <br />6-10 AMPS <br />100 FT. <br />160 FT. <br />245 FT. <br />385 FT. <br />11-15 AMPS <br />70 FT. <br />110 FT. <br />165 FT. <br />255 FT, <br />277 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />480 FT. <br />760 FT. <br />1170 FT. <br />1865 FT. <br />6-10 AMPS <br />240 FT. <br />380 FT. <br />585 FT. <br />930 FT. <br />11-15 AMPS <br />160 FT. <br />250 FT. <br />390 FT. <br />620 FT. <br />SOURCE OF SUPPLY NOTE <br />CONTRACTOR TO VERIFY THE FEEDER ORIGINATION <br />POINT SOURCE OF POWER FOR ALL DISTRIBUTION <br />BOARDS, PANELBOARDS, AND BUSWAYS AFFECTED BY <br />THE REMODEL SCOPE OF WORK. PROVIDE A <br />LAMINATED PLASTIC NAMEPLATE PER SPECIFICATIONS <br />INDICATING THIS INFORMATION. <br />EXAMPLES: <br />H1A FED FROM MSWB <br />L1 D FED FROM H1 B VIA T1 D <br />CIRCUIT SIZING NOTE <br />ALL CONDUIT AND CONDUCTOR SIZES ARE BASED ON <br />EMT WITH 40% FILL, 75-C RATED TERMINATIONS AND <br />TYPE THHN/THWN-2 INSULATION. FOR NON -EMT CONDUIT <br />OR TERMINATIONS RATED LESS THAN 750C OR <br />INSULATION TYPES LESS THAN THHN/THWN-2, MODIFY <br />SIZES ACCORDING TO NEC. <br />1 -1 ' - -- -- 1 EXISTING CONDITIONS WERE TAKEN FROM EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />1" = 60'-0" <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY. NO ADDITIONAL <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />EXISTING CONDITIONS, CONDITIONS THAT OCCUR DUE TO FAILURE TO <br />FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />w <br />wrwv W o <br />(0 CCM <br />= eM <br />II�Y� <br />2 U 00 <br />?� Z i <br />Z�� <br />o g <br />o <br />4:64 <br />i <br />W } V) 0 <br />Do X..28> <br />5 <br />oFW`w'F�ZzvOzia <br />W <br />=ZW 'aw�F z <br />MW F�LLFLLOOoaw8 <br />ww o'z'<wuQVOi�m <br />O0 <br />ay �QOF¢-o=jUt=-�¢ <br />z <br />O <br />LL LL <br />¢Li.J WNN R000wF-0x0 <br />35LL <br />F- <br />zn DozzV%=z I-z <br />OwuiQ�aw a=U00< <br />2,un,g �,OWQzF-<,-QO <br />¢U w <br />QQ(nJOcwrnwo <br />K aXCL R• 2ZJU�J� W 00Fr <br />a <br />oox�-w Uia-Szit(nX: <br />U)wazF�OF¢¢OwanFw <br />�Dnwi ()ocna.Ow�-li�I¢F <br />z <br />F <br />J <br />D <br />m <br />z <br />O <br />U <br />% J <br />O C L.L <br />~p O <br />-��0 <br />o a <br />0 � O <br />O <br />W <br />O <br />0� <br />W <br />N W <br />m <br />D <br />z <br />m <br />O <br />ISSUE BLOCK <br />CHECKED BY: <br />JH <br />DRAWN BY: <br />EE,SFM <br />PROTO CYCLE: <br />01/28/22 <br />DOCUMENT DATE: <br />03/17/22 <br />KA Yy� <br />No. 849 0 <br />STATE OF ' <br />''1/yttt, I 111ttl0 04/07/2022 <br />y. by Joanne Hoban <br />DN:C=U <br />`.4�1 <br />an ssodates.com. <br />_ atesLLCJoanne bP Ewing. CN=Joarre <br />n: I it to the accuracy <br />a and integ ,this document. <br />13: 10:56-05'00' <br />ELECTRICAL <br />PLAN, <br />ONE -LINE, <br />SYMBOLS, <br />NOTES & <br />SCHEDULES <br />SHEET: <br />E 1 <br />