Laserfiche WebLink
PROJECT NO: <br />SHEET NO: ]0': <br />1935000706 <br />4 <br />•13 ° <br />BU'RKHOLDER <br />JBAJOHNSTON <br />PROJECTNAME: <br />AsSOCIATES <br />#0706 - Zephyrhills, FL <br />MADE BY: <br />DATE.MAV <br />consulting structural engineers <br />03/26/19 <br />930 C4'NTRAL - KANSAS CITY, MO 64105 <br />CHECKED BY: <br />DATE: <br />816,421.4200 - WWW.)13AENGR.00M <br />Shelving / Single Sided 90" Tall "X"5 Level <br />24X <br />2017 FBC / IBC 2015 / ASCE 7-10 / 2012 RMI (ANSI/MH16.1-12) <br />Seismic Importance Factor = 1.5 <br />Supported on Elevated Floor (Y/N): No <br />WOrl"` <br />Total Load per shelf = 150lbs <br /># of Levels = Wall 5 Level <br />Uniform Weight per level = 18.75 psf/shelf <br />Weight of Unit = 100 lbs <br />Anchorage spacing/Trib width = 8 ft <br />(Frames are assumed to be 4'-O' oc ) <br />Shelf depth = 24 in <br />h,= Din <br />Shelf Load / Level <br />h,= Din <br />hT = Din <br />he= Din <br />h,= 21 in <br />300 lbs <br />h, = 21 in <br />300 lbs <br />h3 = 21 In <br />300 lbs <br />h2= 21 in <br />300 lbs <br />h, = 6 in <br />300 lbs <br />Total Shelf Height, H, = 90 in <br />Unit Height, Hp = 90 in <br />Unit Base Depth, D = 15 in <br />ci <br />Cs <br />Overturning Stability Load cases are per ASCE 7 sect. 15.5.3.E : <br />Load Case V [per RMI sect. 2.6.8(1) - PL=0.67(PL)] <br />Load Case 2' [per RMI sect. 2.6.8(2) - PL=1.0(PL)] <br />[per RMI sect. 2.6.2, PLRF =1.0] <br />[per RMI sect. 2.6.2, PLRF = 1.0] <br />Seismic (C,)(Ip) = 0.023 W, (Cross -Aisle) <br />Seismic (C,)(Ip) = 0.023 W, (Cross -Aisle) <br />W. = (0.67)(PLRF)((0.67)PL)+DL = 773.4 lbs <br />W. = (0.67)(PLRF)(0 )PL)+DL = 301.0 lbs <br />Base Shear, V = C,IpW, = 17.9 lbs <br />Base Shear, V = C,IpW, = 7.0 lbs <br />Horizontal forces per level, F. = C„,V (RMI sect 2.6.6) <br />Horizontal forces per level, F = C„,V (RMI sect 2.6.6) <br />(Service Loads, E = 0.7) F.= 0.0 lbs @ 0 in (CM) <br />(Service Loads) F.= 0.0 lbs <br />Note: F3= 0.0 lbs @ 0 in (CM) <br />F.= 0.0 lbs <br />(CM) = Product Center of F7= 0.0 lbs @ 0 in (CM) <br />FT= 0.0 lbs <br />Mass typically 6 inches F6= 0.0 lbs @ 0 in (CM) <br />F.= 0.0 lbs <br />above the top of shelf at F5= 4.1 lbs @ 96 in (CM) <br />Fs = 4.2 lbs @ 96in (CM) <br />each level. F4 = 3.2 lbs @ 75 in (CM) <br />F4 = 0.0 lbs <br />F3 = 2.3 lbs @ 54 in (CM) <br />F3 = 0.0 lbs <br />F2 = 1.4 lbs @ 33 in (CM) <br />F2 = 0.0 lbs <br />F, = 0.5 lbs @ 12 in (CM) <br />F, = 0.0 lbs; <br />F. = 1.0 lbs @ 45 in (CM) <br />F. = 0.7 lbs @ 45in (CM) <br />If, = 17.9 lbs (@ Factored Loads) <br />If, = 7.0 lbs (@ Factored Loads) <br />Calculate Overturning Moment (Service), MOT = Ffh; <br />Calculate Overturning Moment (Service), MOT = Efhi <br />MOT = 859 in-lbs <br />MOT = 436 in-lbs <br />Calculate Resisting Moment (Service), MRST <br />Calculate Resisting Moment (Service), MR, <br />MR, = 8250 in-lbs <br />MRST = 3000 in-lbs <br />Factor of Safety <br />Factor of Safety <br />FOS = 9.605 <br />FOS = 6.887 <br />NO UPLIFT - NO ANCHORS REQUIRED <br />NO UPLIFT - NO ANCHORS REQUIRED <br />Base Reactions: <br />Reactions (Service Loads): LC #1 <br />LC #2 T%v x 22GA STEEL <br />i ANCHOR STRAP <br />Rh= 6lbs <br />2lbs 3J"" <br />PLACE STRAP AT <br />R = 0lbs (No Uplift) <br />0 lbs (No Uplift) 14tip <br />EACH END FRAME <br />Overturning FOS = 9.605 >=1.5 <br />6.887 >= 1.5 ? n <br />- - - - <br />AND 8.0-oc (MAX) AT <br />INTERIOR FRAMES. <br />Sliding Restraint force, RRST / FOS = 111lbs / 17.674 >= 1.5 OK <br />45lbs / 18.364 >= 1.5 OK <br />i `� <br />TYPIUNC>. <br />Reactions (Factored Loads): LC #1 <br />�, <br />LC #2 m c c_} <br />t301T <br />Base Shear (Ruh) = 18 lbs <br />< <br />7 lbs J <br />P E R STRAP, <br />PER STRAP, <br />Net Uplift (Rp„) = 0 Ibs <br />._ <br />0 Ibs -••- <br />TYP J UNO. <br />Overturning + Gravity (Pp) = 829 lbs <br />252 lbs Ii . 5 h , ] i) f <br />j <br />Tension Allowables <br />Anchor Design (using "Cracked Concrete" Properties) <br />Steel Strength, (0.75)�N„ = 4239 lbs <br /><-ACI 318-14 Eq 17.4.1.2 <br />Try: 3/870DeWalt Screw Bolt+'- Anchor - 2" embed. <br />Concrete Breakout, (0.75)aN,a,= 636lbs <br /><--ACI 318-14 Eq 17.4.2.1a <br />Embedment = 2 in <br />Pullout Strength, (0.754Np = NA <br /><-ACI 318-14 Eq 17.4.3.1 <br />V, = 2500"psi <br />LC #1 <br />LC #2 <br />en '= Din <- Eccen. Of Anchor <br />Factored Tension Load (N) = 0 lbs <br />0 lbs <br />h,, = 1.33 in 1.5(h,,) = 2 in <br />max tension stress ratio (TSR) = 0.000 OK <br />0.000 OK <br />c, = 5 In 1.5(c,) = 7.5 in <br />Shear Allowables <br />Conc. thickness, t= 4In <br />Steel Strength, +V„= 1449Ibs <-ACI 318-14 <br />Eq 17.5A.2c <br /># of Anchors, n = ' 1 anchors per connection <br />Concrete breakout, �Vpp,= 1578 lbs <_ACI 318-14 <br />Eq 17.5.2.1 b <br />Sx= Din <br />Concrete pryout,+V.= 913lbs <-ACI318-14Eg17.5.3.1b <br />A„ = 0.094 InA2 <br />LC #1 <br />LC #2 <br />Factored Shear Load (Vp) = 18 lbs <br />7 lbs <br />Max shear stress ratio (VSR) = 0.020 OK <br />0.008 OK <br />Combined shear and tension stress ratio (TSR + VSR) = 0.020 < 1.2 OK - LC#1 (controls) <br />USE: NO UPLIFT - USE (1) 3/8"0 DeWalt Screw Bolt+ Anchor - 2" embed. ICC REPORT #ESR-3889 <br />24X - Half Gondola <br />