My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5053 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5053 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 9:54:23 AM
Creation date
2/18/2025 3:14:33 PM
Metadata
Fields
Template:
Building Plans
Street #
5053
Location
Gall Blvd
Contractor
Sunstate Aluminum
Building Plans - Permit #
9593
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Arch Aluminum & Glass Company, Inc. <br />NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br />A. DRAWINGS (transferred from file # 05-1012.05) <br />1. Manufacturer's die drawings and sections. <br />2. Drawing No. 05-319, titled "NI Series Aluminum Medium Stile Outswing Door Non <br />Impact", sheets 1 through 9 of 9, dated 10/02/05 and last revised on Apr 18, 2006, <br />prepared by EngCo Inc., signed and sealed by Pedro De Figueiredo, P.E. <br />B. TESTS (transferred from file # 05-1012.05) original test conducted per SFBC, PA 202-94 <br />now known as TAS 202-94. <br />1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 <br />2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 <br />3) Water Resistance Test, per FBC, TAS 202-94 (Not performed) <br />4) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 <br />Along with installation diagram of aluminum out -swinging impact entrance door with <br />fixed light prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL- <br />1510, dated 12/06/96, signed and sealed by Gilbert Diamond, P.E. <br />2. Additional Re -verification test per TAS 202-94: Test report No. FTL 5072 dated <br />10/16/2006, issued by Fenestration Testing Laboratory, Inc, signed and sealed by <br />Edmundo Largaespada, P. E. <br />C. CALCULATIONS (transferred from file # 05-1012.05) <br />1. Anchor Calculations and structural analysis, complying with FBC-2004, prepared by <br />EngCo Inc., dated 03/09/06, signed and sealed by Pedro De Figueiredo, P.E. <br />2. Glazing complies with ASTM E1300- 98 &-02 <br />D. QUALITY ASSURANCE <br />1. Miami Dade Building Code Compliance Office (BCCO). <br />E. MATERIAL CERTIFICATIONS <br />1. None <br />F. STATEMENTS (transferred from file # 05-1012.05) <br />1. Statement letter of conformance and no financial interest, prepared by Engco Inc., dated <br />10110105, signed and sealed by Pedro DeFigueiredo, P.E. <br />2. Statement letter of compliance, part of above referenced test reports. <br />G. OTHER <br />1. This renews NOA # 05-1012.05 expiring December 31, 2007. <br />2. Test Proposal # 06-0273 approved by BCCO. <br />3. Previous associated files to this approval are NOA(s) # 01-0226.05. <br />Ishaq I. Chanda, P.E. <br />Product Control Examiner <br />NOA No 06-1129.02 <br />Expiration Date: December 31, 2011 <br />Approval Date: February 01, 2007 <br />E-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.