My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7866 Gall Blvd (7)
Zephyrhills
>
Building Department
>
Building Plans
>
7866 Gall Blvd (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:07:51 AM
Creation date
2/18/2025 3:14:54 PM
Metadata
Fields
Template:
Building Plans
Street #
7866
Location
Gall Blvd
Contractor
IContractors
Building Plans - Permit #
5463
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM —SPECIFIC 6.5.3.2.3 Mechanical <br />Reset static pressure setpoint for DDC controlled <br />VAV boxes reporting to central controller based on <br />the zones requiring the most pressure. Controls <br />provide: zone damper monitoring or indicator of <br />static pressure need; autodetection, alarm, and <br />operator override of zones excessively triggering <br />reset logic. <br />SYSTEM —SPECIFIC 6.5.3.3 Mechanical <br />Multiple zone VAV systems with DDC of individual <br />❑ <br />❑ <br />zone boxes have static pressure setpoint reset <br />controls. <br />SYSTEM —SPECIFIC 6.5.3.5 Mechanical <br />Multiple zone HVAC systems have supply air <br />0 <br />temperature reset controls. <br />SYSTEM —SPECIFIC 6.5.4.1 Mechanical <br />System turndown requirement met through <br />❑ 0 <br />13 <br />multiple single -input boilers, one or more <br />modulating boilers, or a combination of <br />single -input and modulating boilers. <br />Boiler input between 1.0 MBtu/h and 5 MBtu/h <br />has 3:1 turndown ratio, boiler input between 5.0 <br />MBtu/h and 10 MBtu/h has 4:1 turndown ratio, <br />boiler input > 10.0 MBtu/h has 5:1 turndown ratio. <br />HVAC 6.5.4.2 Mechanical <br />HVAC pumping systems with >= 3 control values <br />❑ 13 <br />❑ <br />designed for variable fluid flow (see section <br />details). <br />SYSTEM —SPECIFIC 6.5.4.3, 6.5.4.3.1, Mechanical <br />Fluid flow shutdown in pumping systems to <br />❑ ❑ <br />0 <br />6.5.4.3.2 <br />multiple chillers or boilers when systems are shut <br />down. <br />SYSTEM —SPECIFIC 6.5.4.4 Mechanical <br />Temperature reset by representative building <br />loads in pumping systems >10 hp for chiller and <br />boiler systems >300,000 Btu/h. <br />SYSTEM —SPECIFIC 6.5.4.5.1 Mechanical <br />Two -position automatic valve interlocked to shut <br />013 <br />off water flow when hydronic heat pump with <br />pumping system >10 hp is off. <br />SYSTEM —SPECIFIC 6.5.4.5.2 Mechanical <br />Hydronic heat pumps and water-cooled unitary air <br />❑ ❑ <br />❑ <br />conditioners with pump systems >5 hp have <br />controls or devices to reduce pump motor <br />demand. <br />SYSTEM —SPECIFIC 6.5.5.2.1 Mechanical <br />Fan systems with motors or array of motors <br />❑ <br />(inlcuding the motor service factor) with <br />connected power totaling >=5 hp associated with <br />heat rejection equipment to have controls and/or <br />devises that result in fanmotor demand of — 30% <br />of design wattage at 50% of design airflow and <br />automatically modulates fan speed to control the <br />leaving fluid temperature or condensing <br />temp/pressure of heat rejection device. <br />SYSTEM —SPECIFIC 6.5.5.2.2 Mechanical <br />Multicell heat rejection equipment with <br />❑ <br />❑ <br />variable -speed fan drives installed that operate <br />the maximum number of fans allowed that comply <br />with manufacturers specs and control all fans to <br />the same fan speed required for the <br />instantaneous cooling duty. <br />SYSTEM —SPECIFIC 6.5.7.1 Mechanical <br />Conditioned supply air to space with mechanical <br />0❑ <br />❑ <br />exhaust — the greater of criteria of supply flow, <br />required ventilation rate, exhaust flow minu the <br />available transffer air (see section details). <br />HVAC 6.5.7.2.1 Mechanical <br />Kitchen hoods >5,000 cfm have make up air <br />>=50% of exhaust air volume. <br />SYSTEM —SPECIFIC 6.5.7.2.2 Mechanical <br />Kitchen hoods with a total exhaust airflow rate <br />>5000 cfm meet replacement air, ventilation <br />system, or energy recovery requirements shown <br />in Table 6.5.7.1.3. <br />SYSTEM —SPECIFIC 6.5.7.2.3 Mechanical <br />Kitchen hoods with a total exhaust airflow rate <br />>5000 cfm meet replacement air, ventilation <br />system, or energy recovery requirements. <br />HVAC 6.5.7.2 Mechanical <br />Fume hoods exhaust systems >=5,000 cfm have <br />❑ <br />VAV hood exhaust and supply systems, direct <br />make-up air or heat recovery. <br />HVAC 6.5.8.1 Mechanical <br />Unenclosed spaces that are heated use only <br />❑ <br />radiant heat. <br />EnergyGauge Summit@ Fla/Com-2020. Effective Date: Dec 31, 2020 <br />Florida Building Code, Seventh Edition (2020) - Energy Conservation C402.1.1: ASHRAE Energy Cost Budget Option <br />5/19/2022 Page 13 of 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.