My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Daerr Ridge St (3)
Zephyrhills
>
Building Department
>
Building Plans
>
Daerr Ridge St (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:33:54 PM
Creation date
2/18/2025 4:52:25 PM
Metadata
Fields
Template:
Building Plans
Location
Daerr Ridge St
Contractor
Starlight Homes
Description
Tyson 7 Plex
Building Plans - Permit #
6495
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641471 <br />TTH126-132 <br />C3A <br />Jack -Open <br />4 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:21:59 2023 Page 1 <br />ID: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PSB7OH g3NSgPgnL8w3u ITXbGKWrC Doi7J4zJC?f <br />Q93-3-10 <br />' 3-3-10 1 <br />2x4 = <br />3-3-10 <br />M <br />ro <br />Scale = 1:13.2 <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in <br />(loc) Vdefl Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.26 <br />Vert(LL) -0.01 <br />2-4 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.11 <br />Vert(CT) -0.01 <br />2-4 >999 180 <br />BOLL 0.0 <br />Rep Stress Incr YES <br />WB 0.00 <br />Horz(CT) -0.00 <br />3 n/a n/a <br />BO,DL 10.0 <br />Code FBC2020rrPI2014 <br />Matrix-P <br />Weight: 12 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied or 3-3-10 oc purlins. <br />BOT CHORD 2x4 SP No.2 <br />BOT CHORD <br />Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical <br />Max Horz 2=126(LC 12) <br />Max Uplift 3=-80(LC 12), 2=138(LC 12) <br />Max Grav 3=81(LC 17), 2=188(LC 1), 4=62(LC 3) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown <br />NOTES- (7) <br />1) Wind: ASCE 7-16; Vuit=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-2-14 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rein loading requirements specific <br />to the use of this truss component. <br />3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />5) Refer to girder(s) for truss to truss connections. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3 and 138 lb uplift at <br />joint 2. <br />7) ,'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Jongnln Velez PE No.68182 <br />.LDTek lac. DBA YBTek CSA FL C'ert 4634 <br />16023 SMoglec Ridge Rd. <br />Ckeslerrteld. MO 63017 <br />Due: <br />May 25,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />-- <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYMI Quality Crkerls, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd <br />Saferylnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.