Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30850247 <br />TTH27-33 <br />T06A <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Mon Jun 1912:29:40 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJCW <br />12-0-3 18-2-6 219-10 317-13 36-6-0 43-0-0 <br />-0 6-6-0 5-10-3 5-10-3 6-7-3 5-10-3 5-10-3 6-" <br />5x6 = <br />5.00 12 <br />6 19 <br />5x8 = <br />720 <br />Scale = 1:75.1 <br />3x8 = .r « — 15 — 14 10 11 1. 11 3x8 = <br />3x4 = <br />9-5-2 <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />BCDL <br />10.0 <br />Code FBC2020fTP12014 <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 <br />BOT CHORD <br />2x4 SP No.1 *Except* <br />13-16: 2x4 SP No.2 <br />WEBS <br />2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 11=0-3-8 <br />Max Horz 2=253(LC 11) <br />Max Uplift 2=944(LC 12), 11=857(LC 12) <br />Max Grav 2=1873(LC 17), 11=1822(LC 18) <br />4x6 = 3x8 = <br />18-2-6 24-9-10 <br />3x4 = 4x6 = <br />3x4 = <br />CSI. <br />DEFL. <br />in (loc) Vdefl Ud <br />PLATES GRIP <br />TC 0.87 <br />Vert(LL)-0.4012-14 >999 240 <br />MT20 244/190 <br />BC 0.98 <br />Vert(CT) -0.70 12-14 >734 180 <br />WB 0.99 <br />Horz(CT) <br />0.20 11 n/a n/a <br />Matrix-SH <br />Weight: 221 lb FT = 20% <br />BRACING - <br />TOP CHORD <br />Structural wood sheathing directly applied or 2-0-13 oc purlins. <br />BOT CHORD <br />Rigid ceiling directly applied or 2-2-0 oc bracing, Except: <br />5-7-5 oc bracing: 14-15. <br />WEBS <br />1 Row at midpt 7-15 <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3935/2089, 3-5=-3693/1971, 5-6=2725/1611, 6-7=2483/1560, 7-8=2734/1605, <br />8-10=-3710/1974, 10-11=-3954/2108 <br />BOT CHORD 2-17=-1844/3753, 15-17=-1514/3165, 14-15=-1112/2483, 12-14=1504/3011, <br />11-12=-1842/3589 <br />WEBS 3-17=-333/332, 5-17=-192/687, 5-15=-820/522, 6-15=-297/754, 7-14=-298/837, <br />8-14=-823/525, 8-12=-217/693, 10-12=338/353 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 18-2-6, Exterior(2R) <br />18-2-6 to 24-3-6, Interior(1) 24-3-6 to 24-9-10, Exterior(2R) 24-9-10 to 30-7-13, Interior(1) 30-7-13 to 42-10-4 zone; cantilever left and <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = I O.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (#=lb) <br />2=944, 11=857. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />Iv <br />0 <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joagnta Velez PE Ne.68182 <br />NDTek Luc. DDA AIlTek USA FI. Cert 6634 <br />16023 Sni igley Ridge Rd. <br />C6eaterOeW. A10 63017 <br />DAte: <br />June 20,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />